Jungmin Lee, Armon Sharei, Woo Young Sim, Andrea Adamo, Robert Langer, Klavs F. Jensen, and Moungi G. Bawendi
- Cells
- Cancer Cell Lines
- Cargos
- nanoparticle, Polymers
What this document says
This document reports delivery of engineered quantum dot (QD) nanoparticles into the cytoplasm of live HeLa cells using a novel microfluidic device. The device rapidly deforms cells as they pass through a constriction, producing transient membrane disruptions that allow aqueous QDs (~13 nm hydrodynamic diameter) to diffuse into the cytosol. QD constructs were engineered with a disulfide-linked Rox dye so that cytosolic reduction would disrupt FRET and restore QD fluorescence; microscopy and flow cytometry assays show increased QD signal and reduced Rox signal in a subset of treated cells, consistent with cytosolic delivery and chemical accessibility. Delivery occurred at high throughput (~10,000 cells/s) with delivery to roughly 35–40% of cells and sustained viabilities of >80–90%, and single unaggregated QDs were observed blinking in the cytosol after treatment.
Abstract
The authors describe high-throughput delivery of quantum dots into live cell cytoplasm using an uncomplicated microfluidic device while maintaining cell viabilities of 80–90%. They verify that delivered nanoparticle surfaces interact with the cytosolic environment by using a QD–disulfide–Rox construct whose FRET-based emission changes upon disulfide cleavage. Confocal microscopy, flow cytometry, and single-particle imaging indicate diffuse cytoplasmic staining, chemical accessibility to cytosolic reductants, and unaggregated single QDs suitable for imaging.
QD delivery into the cytosol
Cells in suspension are forced through a microfluidic constriction that rapidly deforms the membrane, generating transient disruptions through which macromolecules such as QDs can diffuse into the cytosol. Confocal images show diffuse cytoplasmic QD staining immediately after treatment and after 48 h incubation, with QDs excluded from the nucleus. The device delivered QDs into approximately 35–40% of cells at ~10,000 cells/s while maintaining >80% cell viability as measured by flow cytometry.
Construct design, absorbance, and stability in various media
QDs were coated with poly-imidazole ligands (PILs) bearing PEG for water solubility. A QD–disulfide–Rox construct was prepared by linking Rox dyes to PIL thiols via disulfide bonds (average ~13 Rox per QD), producing strong FRET quenching of QD emission when intact. The construct absorbs at both QD and Rox wavelengths; in full culture media at 37 °C the disulfide bond is stable extracellularly. In solution assays, the cytosolic reductant glutathione and the non-thiol reductant TCEP both cleave the disulfides and restore QD fluorescence, supporting disulfide cleavage rather than PIL displacement as the mechanism of QD fluorescence recovery.
Live cell confocal microscopy and flow cytometry (chemical accessibility)
Treated cells (device-processed) show diffuse cytoplasmic fluorescence that shifts from red (Rox) toward green (QD) over hours, whereas control cells (incubated with construct but not device-treated) show membrane-associated ring fluorescence and no increase in QD channel. Line-graph analysis shows a crossover in treated cells where QD fluorescence surpasses Rox fluorescence between ~2–4 hours, consistent with cytosolic disulfide reduction. Flow cytometry of the treated population shows an increase in average QD fluorescence peaking around 9 hours and bimodal fluorescence histograms indicative of a delivered subset (~35%), while Rox fluorescence declines broadly as membrane-bound constructs are lost to medium. Viability measured by propidium iodide is within ~10% of controls.
Single QD tracking in cell cytosol
At low QD concentration, epifluorescence imaging after a 10-hour incubation revealed blinking spots consistent with single, unaggregated QDs in the cytosol. Intensity traces show intermittency (blinking) with non-binary appearance attributed to 500 ms acquisition bin times. This demonstrates the possibility of single-molecule imaging of delivered QDs in live cell cytosol following device treatment.
Preparation of water-soluble QD and QD-disulfide-Rox constructs
CdSe/CdS core–shell QDs were phase-transferred from hydrophobic ligands to water using PILs containing combinations of PEG, histamine, and lipoic acid sidechains. Ligand exchange involved precipitation, re-dispersion, PIL addition, solvent changes, and final dialysis into PBS (pH 7.4); concentrations were determined by UV–Vis spectroscopy.
Cytosolic delivery of QD constructs (experimental protocol)
For delivery, cells were aliquoted into PBS containing QD, pipetted into the microfluidic device, and driven through channels at constant pressure, followed by a 5 min incubation and centrifugation to remove excess QDs. Controls were exposed to QD solution for equivalent duration without device processing.
Confocal microscopy
Live-cell confocal imaging used a Nikon TE2000-U with 60x water-immersion objective and 488 nm excitation. QD541 emission was collected through a 535/30 filter and Rox through a 605/30 filter; images are averages from eight scans.
What the figures show
- Figure 1 shows (a) a schematic of the microfluidic device and the flow of cells through a constriction, (b) the hypothesized method of nanoparticle entry where rapid cell deformation creates transient membrane disruptions allowing diffusion of nanoparticles into the cytosol, and (c) an overlay of transmission and confocal fluorescence images with z-section confocal fluorescence of treated cells immediately after treatment (top) and after 48 h incubation (bottom). The images show diffuse cytoplasmic staining constrained outside the nucleus; scale bar 10 μm.
- Figure 2 depicts construct design and photophysical characterization: (a) a schematic of the free poly-imidazole ligand (PIL) before dye conjugation (left) and the resulting QD–disulfide–Rox construct (right), (b) the absorbance spectrum indicating features from both QD and Rox with excitation at 488 nm and 405 nm preferentially absorbed by QDs, (c) stability of FRET (QD to Rox) in full culture media at 37 °C/5% CO2 indicating the disulfide bond is not cleaved extracellularly, (d) restoration of QD fluorescence upon treatment with the thiol reductant glutathione showing disulfide cleavage, and (e) similar recovery with the non-thiol reductant TCEP, supporting disulfide bond cleavage as the mechanism.
- Figure 3 contains live-cell confocal images and fluorescence intensity analysis: (a) confocal images of treated cells (top) showing diffuse green fluorescence and control cells (bottom) showing membrane-associated ring fluorescence; scale bar 10 μm. (b) A time-course of average fluorescence per cell in green (QD) and red (Rox) channels for treated and control cells, normalized to the 0 h time point; treated cells show a crossover to increased QD fluorescence between ~2–4 hours, consistent with cytosolic reduction of disulfides.
- Figure 4 presents flow cytometry results: (a) average per-cell fluorescence over time showing increased QD fluorescence only in treated cells and Rox fluorescence declining toward autofluorescence by 24 h, (b) histograms of fluorescence intensity distributions in QD and Rox channels at selected time points showing the treated population becomes bimodal in QD signal (indicating a delivered subset of ~35%), and (c) propidium iodide–based viability measurements showing treated cell viability within ~10% of controls.
- Figure 5 shows epifluorescence images of unaggregated single QDs within the cell cytosol after device treatment with 10 nM QD solution (top) and corresponding blinking intensity traces for three labeled QDs (A, B, C) in green with autofluorescence traces in grey (bottom). The blinking traces exhibit non-binary behavior due to 500 ms acquisition bin times; scale bars are 10 μm.
The summary and sections were written from the public full text of the linked paper. They are not a word-for-word extract.
This publication refers to SQZ Biotechnologies, a separate company previously founded by Dr. Armon Sharei. Dr. Sharei founded Portal Biotechnologies (Watertown, MA), which is develops the next generation of the platform technology mentioned in this publication.
# Nonendocytic Delivery of Functional Engineered Nanoparticles into the Cytoplasm of Live Cells Using a Novel, High-Throughput Microfluidic Device
This page is a text version of a Portal Biotechnologies publication. The bibliographic record is labeled in the text so it can be read without the surrounding website.
## Bibliographic record
- Title: Nonendocytic Delivery of Functional Engineered Nanoparticles into the Cytoplasm of Live Cells Using a Novel, High-Throughput Microfluidic Device
- Document type: Publication
- Year: 2012
- Outlet: NANO LETTERS
- Cells: Cancer Cell Lines
- Cargos: nanoparticle, Polymers
- Page URL: https://portal.bio/publications/2012-nonendocytic-delivery-of-functional-engineered-nanoparticles-into-the-cytoplasm-of-li--ajkHaxEAACkAc-GX
- Markdown URL: https://portal.bio/publications/2012-nonendocytic-delivery-of-functional-engineered-nanoparticles-into-the-cytoplasm-of-li--ajkHaxEAACkAc-GX.md
- External publication: https://pubs.acs.org/doi/abs/10.1021/nl303421h
## Portal description
Jungmin Lee, Armon Sharei, Woo Young Sim, Andrea Adamo, Robert Langer, Klavs F. Jensen, and Moungi G. Bawendi
## Summary
This document reports delivery of engineered quantum dot (QD) nanoparticles into the cytoplasm of live HeLa cells using a novel microfluidic device. The device rapidly deforms cells as they pass through a constriction, producing transient membrane disruptions that allow aqueous QDs (~13 nm hydrodynamic diameter) to diffuse into the cytosol. QD constructs were engineered with a disulfide-linked Rox dye so that cytosolic reduction would disrupt FRET and restore QD fluorescence; microscopy and flow cytometry assays show increased QD signal and reduced Rox signal in a subset of treated cells, consistent with cytosolic delivery and chemical accessibility. Delivery occurred at high throughput (~10,000 cells/s) with delivery to roughly 35–40% of cells and sustained viabilities of >80–90%, and single unaggregated QDs were observed blinking in the cytosol after treatment.
## Sections
### Abstract
The authors describe high-throughput delivery of quantum dots into live cell cytoplasm using an uncomplicated microfluidic device while maintaining cell viabilities of 80–90%. They verify that delivered nanoparticle surfaces interact with the cytosolic environment by using a QD–disulfide–Rox construct whose FRET-based emission changes upon disulfide cleavage. Confocal microscopy, flow cytometry, and single-particle imaging indicate diffuse cytoplasmic staining, chemical accessibility to cytosolic reductants, and unaggregated single QDs suitable for imaging.
### QD delivery into the cytosol
Cells in suspension are forced through a microfluidic constriction that rapidly deforms the membrane, generating transient disruptions through which macromolecules such as QDs can diffuse into the cytosol. Confocal images show diffuse cytoplasmic QD staining immediately after treatment and after 48 h incubation, with QDs excluded from the nucleus. The device delivered QDs into approximately 35–40% of cells at ~10,000 cells/s while maintaining >80% cell viability as measured by flow cytometry.
### Construct design, absorbance, and stability in various media
QDs were coated with poly-imidazole ligands (PILs) bearing PEG for water solubility. A QD–disulfide–Rox construct was prepared by linking Rox dyes to PIL thiols via disulfide bonds (average ~13 Rox per QD), producing strong FRET quenching of QD emission when intact. The construct absorbs at both QD and Rox wavelengths; in full culture media at 37 °C the disulfide bond is stable extracellularly. In solution assays, the cytosolic reductant glutathione and the non-thiol reductant TCEP both cleave the disulfides and restore QD fluorescence, supporting disulfide cleavage rather than PIL displacement as the mechanism of QD fluorescence recovery.
### Live cell confocal microscopy and flow cytometry (chemical accessibility)
Treated cells (device-processed) show diffuse cytoplasmic fluorescence that shifts from red (Rox) toward green (QD) over hours, whereas control cells (incubated with construct but not device-treated) show membrane-associated ring fluorescence and no increase in QD channel. Line-graph analysis shows a crossover in treated cells where QD fluorescence surpasses Rox fluorescence between ~2–4 hours, consistent with cytosolic disulfide reduction. Flow cytometry of the treated population shows an increase in average QD fluorescence peaking around 9 hours and bimodal fluorescence histograms indicative of a delivered subset (~35%), while Rox fluorescence declines broadly as membrane-bound constructs are lost to medium. Viability measured by propidium iodide is within ~10% of controls.
### Single QD tracking in cell cytosol
At low QD concentration, epifluorescence imaging after a 10-hour incubation revealed blinking spots consistent with single, unaggregated QDs in the cytosol. Intensity traces show intermittency (blinking) with non-binary appearance attributed to 500 ms acquisition bin times. This demonstrates the possibility of single-molecule imaging of delivered QDs in live cell cytosol following device treatment.
### Preparation of water-soluble QD and QD-disulfide-Rox constructs
CdSe/CdS core–shell QDs were phase-transferred from hydrophobic ligands to water using PILs containing combinations of PEG, histamine, and lipoic acid sidechains. Ligand exchange involved precipitation, re-dispersion, PIL addition, solvent changes, and final dialysis into PBS (pH 7.4); concentrations were determined by UV–Vis spectroscopy.
### Cytosolic delivery of QD constructs (experimental protocol)
For delivery, cells were aliquoted into PBS containing QD, pipetted into the microfluidic device, and driven through channels at constant pressure, followed by a 5 min incubation and centrifugation to remove excess QDs. Controls were exposed to QD solution for equivalent duration without device processing.
### Confocal microscopy
Live-cell confocal imaging used a Nikon TE2000-U with 60x water-immersion objective and 488 nm excitation. QD541 emission was collected through a 535/30 filter and Rox through a 605/30 filter; images are averages from eight scans.
## What the figures show
- Figure 1 shows (a) a schematic of the microfluidic device and the flow of cells through a constriction, (b) the hypothesized method of nanoparticle entry where rapid cell deformation creates transient membrane disruptions allowing diffusion of nanoparticles into the cytosol, and (c) an overlay of transmission and confocal fluorescence images with z-section confocal fluorescence of treated cells immediately after treatment (top) and after 48 h incubation (bottom). The images show diffuse cytoplasmic staining constrained outside the nucleus; scale bar 10 μm.
- Figure 2 depicts construct design and photophysical characterization: (a) a schematic of the free poly-imidazole ligand (PIL) before dye conjugation (left) and the resulting QD–disulfide–Rox construct (right), (b) the absorbance spectrum indicating features from both QD and Rox with excitation at 488 nm and 405 nm preferentially absorbed by QDs, (c) stability of FRET (QD to Rox) in full culture media at 37 °C/5% CO2 indicating the disulfide bond is not cleaved extracellularly, (d) restoration of QD fluorescence upon treatment with the thiol reductant glutathione showing disulfide cleavage, and (e) similar recovery with the non-thiol reductant TCEP, supporting disulfide bond cleavage as the mechanism.
- Figure 3 contains live-cell confocal images and fluorescence intensity analysis: (a) confocal images of treated cells (top) showing diffuse green fluorescence and control cells (bottom) showing membrane-associated ring fluorescence; scale bar 10 μm. (b) A time-course of average fluorescence per cell in green (QD) and red (Rox) channels for treated and control cells, normalized to the 0 h time point; treated cells show a crossover to increased QD fluorescence between ~2–4 hours, consistent with cytosolic reduction of disulfides.
- Figure 4 presents flow cytometry results: (a) average per-cell fluorescence over time showing increased QD fluorescence only in treated cells and Rox fluorescence declining toward autofluorescence by 24 h, (b) histograms of fluorescence intensity distributions in QD and Rox channels at selected time points showing the treated population becomes bimodal in QD signal (indicating a delivered subset of ~35%), and (c) propidium iodide–based viability measurements showing treated cell viability within ~10% of controls.
- Figure 5 shows epifluorescence images of unaggregated single QDs within the cell cytosol after device treatment with 10 nM QD solution (top) and corresponding blinking intensity traces for three labeled QDs (A, B, C) in green with autofluorescence traces in grey (bottom). The blinking traces exhibit non-binary behavior due to 500 ms acquisition bin times; scale bars are 10 μm.
## Source note
The summary and sections were written from the public full text of the linked paper. They are not a word-for-word extract.