Portal Kits

Simple kits to do everything from altering cell function to providing insights on intracellular biochemical interactions.

Every kit includes: Cell-modifying cargoes · Optimized protocols · MicroBooster™ cartridges · Suggested readouts · Reagents

How the kits work

Every Portal kit runs the same five steps. The cargo and the readout change from kit to kit. The boost stays the same.

01

Isolate / Prepare

Your cells: primary, stem, or a cell line

02

Mix

Cells + cargo (RNA / RNP / antibody / library)

03

Boost

Gateway™ cartridge

04

Reset / Express

Cargo acts or expresses within hours

05

Assay

Function, expression, or screen readout

Cell Engineering Kits

Validated cell engineering workflows, a one stop shop.

Every kit includes: Cell-modifying cargoes · Optimized protocols · MicroBooster™ cartridges · Suggested readouts · Reagents

CELL THERAPY

T Cell Functional Enhancement

  • Best suited for: Human T cells (activated or unstimulated), PBMCs
  • Available enhancements: mbIL2, mbIL12, Perforin, Gzmb, B2M and TCR knockouts
  • Measure endogenous intracellular proteins in live cells
  • Use cases: Cytokine armoring, gene KO, persistence enhancement
Download Info
STEM CELL BIOLOGY

iPSC Generation

  • Best suited for: PBMCs & fibroblasts
  • Available enhancements: Oct4, Sox2, Klf4, cMyc RNA
  • Best suited for: Reprogramming, disease modeling
Download Info
IMMUNOLOGY

APC Enhancement

  • Best suited for: PBMCs, dendritic cells
  • Available enhancements: mbIL2, mbIL12, CD86, custom antigen RNA
  • Best suited for: Immune activation, DC engineering, vaccine research
Download Info
Stem cell biology

HSC Enhancement

  • Best suited for: Hematopoietic stem cells
  • Available enhancements: CXCR4, BCL2
  • Best suited for: Engraftment, survival, stemness preservation
Download Info
NEUROSCIENCE

Neuronal Differentiation

  • Best suited for: iPSC-derived neurons, neural progenitors
  • Available enhancements: NGN2, ASCL1, LMX1A, FOXA2, NURR1, ASOs
  • Best suited for: Neuronal differentiation, disease modeling, Parkinson's/ALS
Download Info

Drug Discovery Kits

Validated live-cell workflows for target engagement, compound profiling, and beyond.

Every kit includes: Cargoes · Optimized protocols · MicroBooster™ cartridges · Suggested readouts · Reagents

Impermeable Candidate Validation in Live Cells

  • Solves: Permeability engineering as a prerequisite for testing cellular activity
  • Cargo: Your impermeable drug candidate
  • Validate and test your candidates in live cells, regardless of permeability
  • e.g. small molecules, macrocycles, peptides
Download Info

Live-Cell Protein Detection

  • Solves: Live-cell context lost to lysis, and target labeling that requires cell engineering.
  • Cargo: Intracellular antibodies (primary & secondary)
  • Measure endogenous intracellular proteins in live cells
  • e.g. p-BTK, p-ERK, p-AKT, p-STAT3, p-MET Compatible with LgBiT/HgBiT reagents
Download Info

Live-Cell Target Engagement

  • Solves: Live-cell context lost to lysis and detergents, and the need to create cell-permeable tracers
  • Cargoes: Your tracers (e.g. NanoBRET) and compounds
  • Enables live-cell target engagement without lysis; supports impermeable tracers
  • e.g. kinase inhibitor profiling, degrader engagement
Download Info

Controllable Surface Antigen Expression

  • Solves: Fixed, hard-to-modulate surface antigen expression in cell lines
  • Cargo: Custom antigen/receptor RNA — single or combinations
  • Express any antigen on any cell in hours
  • e.g. CD19+CD3, BCMA+CD3, HER2+CD3
Download Info

Direct-to-Assay

  • Solves: The stable-line bottleneck: infeasible in primary cells, slow and laborious elsewhere
  • Cargo: Custom RNA encoding tagged POI
  • Run NanoBRET or LgBiT/HgBiT without stable lines
  • e.g. VHL-NanoLuc, HgBiT-tagged POI, HA-tagged POI
Download Info

Intracellular DEL Screening

  • Solves: DEL screens can't be done in live human cells
  • Cargo: Your DEL library
  • Screen intracellular targets with no library bias
  • e.g. iPSCs, HeLa, PBMCs — any cell type
Download Info

What Every Kit Includes

A kit is more than reagents. It's the cargo, protocol, MicroBooster™ cartridges, and suggested readouts. Everything to go from the bench to real data in one workflow.

Portal-sourced cargoes

The cargo your workflow needs, sourced and QC'd by Portal, ready to boost.

Optimized protocols

A step-by-step protocol with cell concentrations, boost settings, and timing already dialed in.

MicroBooster™ cartridges

The consumable cartridges that run the Gateway™ boost, in the box.

Suggested readouts

The assays we'd run to confirm delivery, expression, and function for your cells.

Portal-sourced cargoes

The cargo your workflow needs, sourced and QC'd by Portal, ready to boost.

Optimized protocols

A step-by-step protocol with cell concentrations, boost settings, and timing already dialed in.

MicroBooster™ cartridges

The consumable cartridges that run the Gateway™ boost, in the box.

Suggested readouts

The assays we'd run to confirm delivery, expression, and function for your cells.

Not Sure Which Kit You Need?

Tell us your cells, cargo, and readout. A Portal scientist will point you to the right kit and spec the protocol for your workflow.

Broad Compatibility

Portal’s platform supports delivery to a diverse range of cell types and cargoes

Delivery materials
Validated cell types
mRNA, siRNA, saRNA
Proteins & Peptides
CRISPR RNPs
Small Molecules
Polymers
Nanoparticles
Antibodies
Virus
PBMCs
T cells
B cells
NK cells
iPSCs
Monocytes
RBCs
HSCs
Delivery materials
mRNA, siRNA, saRNA
Proteins & Peptides
CRISPR RNPs
Small Molecules
Polymers
Nanoparticles
Antibodies
Virus
Validated cell types
PBMCs
T cells
B cells
NK cells
iPSCs
Monocytes
RBCs
HSCs

One method, three scales

Gateway

Research Scale

Benchtop instrument for discovery research

  • 0.5-10M cells per run
  • 50-200 µl volume range
  • Compact benchtop unit that fits in any hood
  • Available now

Galaxy-i

High-Throughput Screening

High throughput scale instrument for screening applications with multi well plates.

  • 96/384-well plate compatibility
  • Integrate with existing automation
  • Ideal for DEL, PROTAC, CRISPR screening
  • Available now

Millibooster

Clinical Manufacturing

GMP-ready clinical production system

  • 1 billion+ cells/minute throughput
  • Attach to existing equipment via tube-weld or luer lock connection
  • 2-100mL volume range
  • Available Now