Armon Sharei, Roberta Poceviciute, Emily L. Jackson, Nahyun Cho, Shirley Mao, George C. Hartoularos, Derek Y. Jang, Siddharth Jhunjhunwala, Alexandra Eyerman, Taylor Schoettle, Robert Langer, and Klavs F. Jensen
- Cells
- Cancer Cell Lines
- Cargos
- Polymers, Antibody
What this document says
This document reports experiments using the proprietary mechanoporation platform microfluidic intracellular delivery platform to characterize plasma membrane disruption and recovery kinetics after mechanical deformation. The authors compare device geometries and operating pressures to optimize delivery efficiency and viability, then investigate how extracellular calcium and temperature affect the time it takes pores to reseal. They find that presence of physiological calcium (∼1.8 mM) dramatically shortens membrane repair time (seconds) compared with buffers lacking calcium (minutes), that this calcium-dependent repair limits uptake of macromolecules, and that manipulating repair kinetics (for example, by using calcium-free buffers or running on ice) can improve delivery of large cargos such as antibodies to hard-to-transfect primary naïve murine T cells while maintaining acceptable viability.
Integrative Biology — TECHNICAL INNOVATION
The title page identifies the work as a technical innovation study of plasma membrane recovery kinetics using the proprietary mechanoporation platform microfluidic delivery platform. The abstract summarizes that membrane recovery time depends strongly on calcium in the surrounding buffer (approximately ≥5 minutes without calcium vs. ≈30 seconds with calcium), and that manipulating repair kinetics can improve delivery efficiency up to five-fold without substantially affecting viability. The authors note that membrane repair characteristics observed in HeLa cells translate to primary naïve murine T cells and enable delivery of larger cargos such as antibodies.
Introduction
The introduction frames intracellular delivery challenges and positions physical membrane-disruption approaches (including proprietary mechanoporation platform) as alternatives to vector- and chemistry-based methods. It states that the authors use the proprietary mechanoporation platform platform to examine plasma membrane repair kinetics and the role of extracellular calcium in recovery after mechanical disruption.
Experimental
Experimental methods describe HeLa cell culture and primary naïve murine T cell isolation, device treatment workflows, and flow cytometry analysis. Cells were prepared at 3 × 10^6 cells mL−1 (HeLa) or isolated T cells concentrated after spleen processing. Delivery experiments passed cell suspensions with fluorescent cargos through microfluidic devices at specified pressures; post-treatment recovery and FACS protocols are described. Buffers compared included PBS, PBS with varying CaCl2 concentrations (1.8, 0.9, 0.18 mM), DMEM, and PBS variants (EDTA, extra NaCl). Device nomenclature and operating pressures used in the study are specified.
Results and discussion
The authors characterize device performance and show that device geometry (constriction length, width, and number in series) and operating pressure affect delivery efficiency and viability: longer or multiple constrictions and higher pressure increase delivery but can reduce viability. A new symmetric, two-stage flow-splitting device generation increases throughput (~6× at a given pressure) and yields more homogeneous treatment and >90% cell recovery. They demonstrate a clear calcium dependence for membrane repair: extracellular calcium reduces delivery (less intracellular dextran) in a dose-dependent manner, an effect not reproduced by added sodium. Time-course experiments in which dye was added at defined times after treatment show rapid pore closure (within ~15–30 s) in buffers containing calcium or in DMEM, whereas pores remain open for minutes in calcium-free PBS. Lower temperature
What the figures show
- Figure 1 — Overview of device design and investigated parameters: The figure contains a schematic of the microfluidic device layout, a photograph of a fabricated device, and a cartoon depicting the delivery mechanism. The schematic shows inlet flow split first into 15 parallel channels and then subdivided into 5 channels that each contain a constriction; channel width upstream of constrictions is 30 µm. The photograph displays an assembled glass/silicon device at millimeter scale. The cartoon illustrates a cell being forced through a constriction, its plasma membrane becoming transiently disrupted, delivery material present in the external buffer, diffusion of material into the cell while the membrane is permeable, and subsequent membrane resealing. The panel conveys the device architecture (parallelized channels and constrictions), the conceptual mechanism of mechanically induced transient membrane permeability, and the notion that extracellular molecules can enter cells during the brief recovery window.
- Figure 2 — Delivery performance across device designs: This figure presents three flow cytometry histograms comparing delivery of three cargos (3 kDa cascade blue dextran, 70 kDa fluorescein dextran, and an APC-labeled IgG1 isotype antibody) across four device designs labeled 10-6×5, 50-6, 10-6, and 10-7, plus a control. Each histogram plots fluorescence intensity (x-axis) against cell frequency (y-axis) with colored curves for each device. The data show that the 10-6×5 device yields the highest intracellular fluorescence (greatest delivery) for all three cargos, while the 10-7 design yields the lowest. The panel demonstrates that constriction geometry—particularly multiple 10 mm constrictions in series—produces greater membrane disruption and cargo uptake than shorter or single constrictions, indicating device geometry strongly influences delivery efficiency and distribution homogeneity.
- Figure 3 — Delivery by cell squeezing is calcium dependent: This figure combines fluorescence microscopy images and quantitative flow cytometry plots to compare delivery in PBS (no added calcium), PBS supplemented with 1.8 mM CaCl2, and DMEM. (a) Representative bright-field and fluorescence images show visibly higher intracellular signal for 3 kDa and 10 kDa dextrans in PBS-treated cells than in PBS + Ca treated cells. (b) A plot compares normalized mean delivery intensity in PBS, PBS + Ca, and DMEM, showing reduced delivery when calcium is present or in full medium. (c) A dose–response plot shows normalized delivery intensity decreasing as extracellular calcium concentration increases (tested across different operating pressures). Together these panels show that physiological levels of extracellular calcium accelerate membrane repair and reduce uptake of dextrans after mechanical disruption, and that the calcium effect is dose dependent and consistent across pressures.
- Figure 4 — Pore closure kinetics are calcium dependent: This figure presents time-course plots of normalized intracellular fluorescence after cells are treated in the absence of dye and then exposed to 3 kDa dextran at defined times post-treatment. (a) In PBS versus PBS + 1.8 mM CaCl2, normalized uptake remains high for several minutes in PBS but decays to near baseline within ~15–30 seconds in PBS + Ca. (b) Data for DMEM show rapid closure comparable to PBS + Ca. (c) Comparison of two device designs (50-6 and 10-6) in PBS shows different initial uptake magnitudes but the same prolonged pore openness over minutes in calcium-free buffer. These plots indicate that extracellular calcium (and culture medium) triggers rapid membrane resealing on the order of tens of seconds, whereas absence of calcium permits pores to remain permeable for minutes, explaining earlier observations of increased delivery in calcium-free conditions.
- Figure 5 — Translation to primary naïve murine T cells: This figure shows flow cytometry histograms and delivery data for murine naïve T cells treated by a 30-4 device. Panels (a) and (b) compare uptake of 3 kDa dextran when dye is added at various times after treatment in PBS (no calcium) and PBS + 1.8 mM CaCl2, respectively; in PBS dye uptake persists at later time points, while in PBS + Ca uptake is confined to very early time points, mirroring HeLa results. Panel (c) shows delivery of APC-conjugated IgG1 isotype antibody to naïve T cells when the device was run on ice, demonstrating that manipulating repair kinetics (here by low temperature) enables antibody delivery to these primary cells. The figure demonstrates that calcium- and temperature-dependent membrane repair dynamics observed in HeLa cells translate to primary T cells and can be leveraged to deliver larger macromolecules.
The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.
This publication refers to SQZ Biotechnologies, a separate company previously founded by Dr. Armon Sharei. Dr. Sharei founded Portal Biotechnologies (Watertown, MA), which is develops the next generation of the platform technology mentioned in this publication.
# Plasma membrane recovery kinetics of a microfluidic intracellular delivery platform
This page is a text version of a Portal Biotechnologies publication. The bibliographic record is labeled in the text so it can be read without the surrounding website.
## Bibliographic record
- Title: Plasma membrane recovery kinetics of a microfluidic intracellular delivery platform
- Document type: Publication
- Year: 2014
- Outlet: INTEGRATIVE BIOLOGY
- Cells: Cancer Cell Lines
- Cargos: Polymers, Antibody
- Page URL: https://portal.bio/publications/2014-plasma-membrane-recovery-kinetics-of-a-microfluidic-intracellular-delivery-platform--ajkHXhEAACsAc-Fs
- Markdown URL: https://portal.bio/publications/2014-plasma-membrane-recovery-kinetics-of-a-microfluidic-intracellular-delivery-platform--ajkHXhEAACsAc-Fs.md
- Original file: https://portal-bio.cdn.prismic.io/portal-bio/65cd08df9be9a5b998b5d350_c3ib40215k.pdf
## Portal description
Armon Sharei, Roberta Poceviciute, Emily L. Jackson, Nahyun Cho, Shirley Mao, George C. Hartoularos, Derek Y. Jang, Siddharth Jhunjhunwala, Alexandra Eyerman, Taylor Schoettle, Robert Langer, and Klavs F. Jensen
## Summary
This document reports experiments using the proprietary mechanoporation platform microfluidic intracellular delivery platform to characterize plasma membrane disruption and recovery kinetics after mechanical deformation. The authors compare device geometries and operating pressures to optimize delivery efficiency and viability, then investigate how extracellular calcium and temperature affect the time it takes pores to reseal. They find that presence of physiological calcium (∼1.8 mM) dramatically shortens membrane repair time (seconds) compared with buffers lacking calcium (minutes), that this calcium-dependent repair limits uptake of macromolecules, and that manipulating repair kinetics (for example, by using calcium-free buffers or running on ice) can improve delivery of large cargos such as antibodies to hard-to-transfect primary naïve murine T cells while maintaining acceptable viability.
## Sections
### Integrative Biology — TECHNICAL INNOVATION
The title page identifies the work as a technical innovation study of plasma membrane recovery kinetics using the proprietary mechanoporation platform microfluidic delivery platform. The abstract summarizes that membrane recovery time depends strongly on calcium in the surrounding buffer (approximately ≥5 minutes without calcium vs. ≈30 seconds with calcium), and that manipulating repair kinetics can improve delivery efficiency up to five-fold without substantially affecting viability. The authors note that membrane repair characteristics observed in HeLa cells translate to primary naïve murine T cells and enable delivery of larger cargos such as antibodies.
### Introduction
The introduction frames intracellular delivery challenges and positions physical membrane-disruption approaches (including proprietary mechanoporation platform) as alternatives to vector- and chemistry-based methods. It states that the authors use the proprietary mechanoporation platform platform to examine plasma membrane repair kinetics and the role of extracellular calcium in recovery after mechanical disruption.
### Experimental
Experimental methods describe HeLa cell culture and primary naïve murine T cell isolation, device treatment workflows, and flow cytometry analysis. Cells were prepared at 3 × 10^6 cells mL−1 (HeLa) or isolated T cells concentrated after spleen processing. Delivery experiments passed cell suspensions with fluorescent cargos through microfluidic devices at specified pressures; post-treatment recovery and FACS protocols are described. Buffers compared included PBS, PBS with varying CaCl2 concentrations (1.8, 0.9, 0.18 mM), DMEM, and PBS variants (EDTA, extra NaCl). Device nomenclature and operating pressures used in the study are specified.
### Results and discussion
The authors characterize device performance and show that device geometry (constriction length, width, and number in series) and operating pressure affect delivery efficiency and viability: longer or multiple constrictions and higher pressure increase delivery but can reduce viability. A new symmetric, two-stage flow-splitting device generation increases throughput (~6× at a given pressure) and yields more homogeneous treatment and >90% cell recovery. They demonstrate a clear calcium dependence for membrane repair: extracellular calcium reduces delivery (less intracellular dextran) in a dose-dependent manner, an effect not reproduced by added sodium. Time-course experiments in which dye was added at defined times after treatment show rapid pore closure (within ~15–30 s) in buffers containing calcium or in DMEM, whereas pores remain open for minutes in calcium-free PBS. Lower temperature
## What the figures show
- Figure 1 — Overview of device design and investigated parameters: The figure contains a schematic of the microfluidic device layout, a photograph of a fabricated device, and a cartoon depicting the delivery mechanism. The schematic shows inlet flow split first into 15 parallel channels and then subdivided into 5 channels that each contain a constriction; channel width upstream of constrictions is 30 µm. The photograph displays an assembled glass/silicon device at millimeter scale. The cartoon illustrates a cell being forced through a constriction, its plasma membrane becoming transiently disrupted, delivery material present in the external buffer, diffusion of material into the cell while the membrane is permeable, and subsequent membrane resealing. The panel conveys the device architecture (parallelized channels and constrictions), the conceptual mechanism of mechanically induced transient membrane permeability, and the notion that extracellular molecules can enter cells during the brief recovery window.
- Figure 2 — Delivery performance across device designs: This figure presents three flow cytometry histograms comparing delivery of three cargos (3 kDa cascade blue dextran, 70 kDa fluorescein dextran, and an APC-labeled IgG1 isotype antibody) across four device designs labeled 10-6×5, 50-6, 10-6, and 10-7, plus a control. Each histogram plots fluorescence intensity (x-axis) against cell frequency (y-axis) with colored curves for each device. The data show that the 10-6×5 device yields the highest intracellular fluorescence (greatest delivery) for all three cargos, while the 10-7 design yields the lowest. The panel demonstrates that constriction geometry—particularly multiple 10 mm constrictions in series—produces greater membrane disruption and cargo uptake than shorter or single constrictions, indicating device geometry strongly influences delivery efficiency and distribution homogeneity.
- Figure 3 — Delivery by cell squeezing is calcium dependent: This figure combines fluorescence microscopy images and quantitative flow cytometry plots to compare delivery in PBS (no added calcium), PBS supplemented with 1.8 mM CaCl2, and DMEM. (a) Representative bright-field and fluorescence images show visibly higher intracellular signal for 3 kDa and 10 kDa dextrans in PBS-treated cells than in PBS + Ca treated cells. (b) A plot compares normalized mean delivery intensity in PBS, PBS + Ca, and DMEM, showing reduced delivery when calcium is present or in full medium. (c) A dose–response plot shows normalized delivery intensity decreasing as extracellular calcium concentration increases (tested across different operating pressures). Together these panels show that physiological levels of extracellular calcium accelerate membrane repair and reduce uptake of dextrans after mechanical disruption, and that the calcium effect is dose dependent and consistent across pressures.
- Figure 4 — Pore closure kinetics are calcium dependent: This figure presents time-course plots of normalized intracellular fluorescence after cells are treated in the absence of dye and then exposed to 3 kDa dextran at defined times post-treatment. (a) In PBS versus PBS + 1.8 mM CaCl2, normalized uptake remains high for several minutes in PBS but decays to near baseline within ~15–30 seconds in PBS + Ca. (b) Data for DMEM show rapid closure comparable to PBS + Ca. (c) Comparison of two device designs (50-6 and 10-6) in PBS shows different initial uptake magnitudes but the same prolonged pore openness over minutes in calcium-free buffer. These plots indicate that extracellular calcium (and culture medium) triggers rapid membrane resealing on the order of tens of seconds, whereas absence of calcium permits pores to remain permeable for minutes, explaining earlier observations of increased delivery in calcium-free conditions.
- Figure 5 — Translation to primary naïve murine T cells: This figure shows flow cytometry histograms and delivery data for murine naïve T cells treated by a 30-4 device. Panels (a) and (b) compare uptake of 3 kDa dextran when dye is added at various times after treatment in PBS (no calcium) and PBS + 1.8 mM CaCl2, respectively; in PBS dye uptake persists at later time points, while in PBS + Ca uptake is confined to very early time points, mirroring HeLa results. Panel (c) shows delivery of APC-conjugated IgG1 isotype antibody to naïve T cells when the device was run on ice, demonstrating that manipulating repair kinetics (here by low temperature) enables antibody delivery to these primary cells. The figure demonstrates that calcium- and temperature-dependent membrane repair dynamics observed in HeLa cells translate to primary T cells and can be leveraged to deliver larger macromolecules.
## Layout reading
I will read and transcribe the document for a non-sighted reader. I will only use the publisher short description you provided to identify the subject (the proprietary mechanoporation platform microfluidic intracellular delivery platform) and will not add claims that are not visible in the pages. I will transcribe labeled sections in visual reading order and describe every chart, graph, diagram, photo, or schematic in plain language including what is drawn, what is compared, what the result shows, and how the depicted process works. I will not invent sentences not on the page. I will skip logos, page numbers, and decorative text.
Cover / Title page (page 1)
- Header: Integrative Biology — TECHNICAL INNOVATION
- Title: "Plasma membrane recovery kinetics of a microfluidic intracellular delivery platform†"
- Author line: "Armon Sharei,‡ Roberta Poceviciute,‡ Emily L. Jackson, Nahyun Cho, Shirley Mao, George C. Hartoularos, Derek Y. Jang, Siddharth Jhunjhunwala, Alexandra Eyerman, Taylor Schoettle, Robert Langer* and Klavs F. Jensen*"
- Short abstract paragraph (visible):
- "Intracellular delivery of materials is a challenge in research and therapeutic applications. Physical methods of plasma membrane disruption have recently emerged as an approach to facilitate the delivery of a variety of macromolecules to a range of cell types. We use the proprietary mechanoporation platform delivery platform to examine the kinetics of plasma membrane recovery after disruption and its dependence on the calcium content of the surrounding buffer (recovery time B5 min without calcium vs. B30 s with calcium). Moreover, we illustrate that manipulation of the membrane repair kinetics can yield up to 5× improvement in delivery efficiency without significantly impacting cell viability. Membrane repair characteristics initially observed in HeLa cells are shown to translate to primary naïve murine T cells. Subsequent manipulation of membrane repair kinetics also enables the delivery of larger materials, such as antibodies, to these difficult to manipulate cells. This work provides insight into the membrane repair process in response to mechanical delivery and could potentially enable the development of improved delivery methods."
- Manuscript metadata (visible): Received 16th October 2013; Accepted 25th January 2014; DOI: 10.1039/c3ib40215k
- Insight/innovation/integration box (visible):
- States that physical approaches could overcome challenges of vector-based and chemical methods, but the mechanism of plasma membrane disruption and recovery is poorly understood. They describe new intracellular delivery devices used to characterize membrane disruption/repair. Calcium identified as important factor mediating membrane repair; this insight may govern performance of other physical approaches (ultrasound, electroporation, fluid shear, nanowire-based). Could enable design of more effective delivery systems.
Introduction (page 1 continued)
- Text paragraphs describing:
- General challenges of intracellular delivery; nanoparticle and liposome approaches have limitations, especially in primary cells; endosome escape inefficient. Viral vectors limited and raise safety concerns. Cell-penetrating peptides effective for some protein delivery but also suffer endosome escape problems.
- Physical approaches (electroporation, sonoporation) disrupt plasma membrane to access cytoplasm. They mention proprietary mechanoporation platform used to examine plasma membrane repair kinetics and calcium dependence.
- Author affiliations: Department of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Cambridge, MA 02139, USA. Email contacts: rlanger@mit.edu, kfjensen@mit.edu
- Note: "† Electronic supplementary information (ESI) available. See DOI: 10.1039/c3ib40215k" and "‡ These authors contributed equally to this work."
Page 2 — Experimental (visual reading order)
- Section titles and subsections (in order):
- "Experimental"
- "Cell culture"
- HeLa cells cultured in DMEM with 10% fetal bovine serum and 1% penicillin/streptomycin. One day before delivery, 3 × 10^6 cells were seeded into a 750 cm^2 tissue culture flask. Cells detached: old medium removed; cells washed with 5 mL of PBS, incubated with 5 mL of 0.5% trypsin/EDTA at 37 °C for 10 min, neutralized with 10 mL fresh medium. Resulting suspension split into tubes for conditions. Tubes spun at 800g for 5 min, supernatant discarded, pellet resuspended in buffer to yield 3 × 10^6 cells per mL.
- "Delivery procedure"
- Delivery experiments as described previously. Briefly, suspension of cells and delivery material passed through device at desired pressure. Treated cells (60–80 µL per sample) collected in 96-well plate and allowed to recover >5 min at room temperature. Fresh medium then added prior to further processing or overnight culture. Microfluidic devices used obtained from proprietary mechanoporation platform, USA.
- "Device comparison"
- Cell suspensions prepared in PBS with delivery materials at concentrations: 0.1 mg mL^−1 3 kDa cascade blue dextran, 0.1 mg mL^−1 70 kDa fluorescein labeled dextran, and 0.05 mg mL^−1 APC labeled IgG1 isotype control antibody. Cells passed through device at three pressures (30, 50, 70 psi) using four device types (10-7, 10-6, 50-6, 10-6×5). Treated cells incubated ~5 min post-delivery for membrane recovery. FACS analysis same day. Controls: untreated cells not exposed to dye, untreated cells exposed to dye, and cells treated at 30 psi without exposure to dye.
- "Buffer comparison"
- Preparations: three buffers: PBS, DMEM, and a third buffer (variants listed: 1.8 mM CaCl2 in PBS, 1.8 mM EDTA in PBS, 2.7 mM NaCl in PBS, or medium). Delivery materials same concentrations as above. Cells passed through device at four pressures (30, 50, 70, 100 psi). FACS analysis next day. Controls: untreated cells not exposed to dye, and untreated cells exposed to dye.
- "Calcium dosage"
- Buffers: PBS, 1.8 mM CaCl2 in PBS, 0.9 mM CaCl2 in PBS, 0.18 mM CaCl2 in PBS. Delivery materials same concentrations. Cells passed at four pressures (30, 50, 70, 100 psi). FACS analysis next day. Controls same as above.
- "Membrane recovery kinetics"
- Cell suspension prepared in single buffer (PBS, DMEM, or 1.8 mM CaCl2 in PBS) in absence of delivery material. For zero time point, delivery material added to yield final dye concentration and immediately treated by device at 70 psi. For subsequent time points, cell suspension alone was passed through the device at 70 psi, and dye solution added at set time points (15 s, 30 s, 45 s, 1 min, 1.5 min, 2 min, 3 min, 5 min, 10 min) to yield same final dye concentrations. Treated cells incubated with dyes >5 min post-exposure. HeLa FACS next day; naïve murine T cells FACS same day. Controls: untreated cells not exposed to dye, untreated cells exposed to dye, and cells treated at 70 psi not exposed to dye.
- "FACS sample preparation and analysis"
- Samples prepared in 96-well v-bottom plate and washed with 150 µL PBS per well. Cells suspended in FACS buffer (3% FBS, 1% pluronics, 1% PI in DPBS, 100 µL per well) prior to analysis. Samples run on FACS Canto or LSR Fortessa. Results analyzed using FACS Diva and FlowJo.
- "T cell isolation"
- Spleens from male C57BL6 mice (6–12 weeks). Mechanically disrupted by grinding with serrated tweezers to yield splenocyte suspension. Passed through 40 µm filter; red blood cell lysis performed per instructions (Cat no. 00-4333-57, eBioscience). After lysis, cells concentrated to 2 × 10^8 cells per mL. T cells isolated using EasySep T cell isolation kit (Cat no. 19851, StemCell Technologies). Separation is negative selection (no magnetic particles bound to isolated T cells). Purified T cells then suspended in desired buffer for device treatment.
Page 3 — Results and discussion (visual reading order)
- Section "Results and discussion"
- Subsection "Performance characterization":
- Describes proprietary mechanoporation platform platform: rapid mechanical deformation through microfluidic constriction induces membrane disruption, enabling passive diffusion into cytoplasm. Present system treats each cell individually; parallelization allows high throughput (50,000–500,000 cells per second). Parallelization can lead to heterogeneity because fluid flow profile differs across channels; cell speed affects delivery efficiency and viability. To address this, they developed a new generation of devices increasing throughput and treatment homogeneity (Fig. 1a and b). Devices divide cell flow in two stages and are symmetrical; compared to previous, these devices have higher throughput (~6× at given pressure), accommodate flow in either direction, and provide more homogenous treatment. Measured cell recovery rates for these designs were over 90% (Fig. S2, ESI).
- They conducted characterization using HeLa cells. Devices designed with different constriction lengths, widths, and number of constrictions in series. Design nomenclature: (constriction length) – (constriction width) × (number of constrictions in series). Fluorescently labeled dextran polymers and isotype control antibodies used to assess delivery efficiency for different sized molecules (Fig. 2). For a given constriction width, increasing channel length or number of constrictions in series increases delivery efficiency and reduces cell viability. Increasing operating pressure (cell speed) increased delivery efficiency. The 10-6×5 design appears harsher than 50-6 (higher delivery and lower viability), suggesting multiple 10 mm length constrictions in series are more effective for membrane disruption than a single constriction of equivalent total length. Compared to previously reported design, these devices exhibited a more uniform distribution of delivery material (Fig. 2), suggesting reduced heterogeneity.
- Subsection "Calcium dependent delivery":
- To understand membrane recovery post-treatment, they characterized recovery kinetics and dependence on buffer composition, specifically calcium. Previous studies reported closure of membrane disruptions may be governed by thermodynamic rearrangement or calcium-mediated signaling for active recovery; holes >~200 nm addressed through active recovery, smaller holes by thermodynamic rearrangement. They conducted experiments in buffers with and without calcium to gauge dependence.
- Result noted: Fig. 3 demonstrates that cells treated by a 50-6 device in PBS receive more dextran than those treated in PBS with 1.8 mM calcium (physiological calcium is 1–2 mM). A similar difference observed when comparing full culture media (DMEM) to PBS, indicating calcium likely major determinant (Fig. S5). Calcium response is dose dependent (Fig. 3c) and cannot be recreated by addition of sodium (Fig. S7). These results consistent with previous calcium-mediated membrane repair reports.
Figure 1 (page 3, visual reading order)
- Title/caption visible: "Fig. 1 Overview of device design and investigated parameters."
- Figure components described visually and in caption:
- (a) A schematic of device design and relative positioning of individual channels. Each device symmetrical with two access holes on each side for cells to enter and exit. Flow is first split into 15 separate channels and subsequently subdivided into 5 channels, each containing a constriction. Width of channel prior to constriction is 30 µm.
- (b) Image of a device implemented in glass and silicon. Scale bar 2 mm.
- (c) Illustration of delivery process: membrane of target cell is disrupted after treatment by the constriction and material in surrounding buffer can diffuse into the cell for duration of membrane recovery phase.
- Plain-language description of the figure:
- What is drawn: a schematic layout of the microfluidic device showing how the inlet flow is split into many parallel channels and how each channel contains constrictions; a photograph of an assembled device in glass/silicon; a cartoon showing a cell entering a constriction, its membrane disrupted, delivery material outside the cell, and subsequent membrane recovery.
- What is compared: different channel geometries and arrangement (split into multiple channels then to constrictions), not a data comparison but a design depiction.
- What the result shows: the device architecture used for the experiments and the conceptual mechanism: mechanical constriction causes transient membrane disruption allowing diffusion of extracellular molecules into cytoplasm during membrane recovery.
- How the process works: cells flow through narrow constrictions; deformation disrupts membrane; delivery molecules present in buffer diffuse into cell while membrane is permeable; membrane then reseals.
Page 4 — Figures and Calcium-dependent delivery continued (visual reading)
- Figure 2 (top of page 4)
- Caption text transcribed:
- "Fig. 2 Delivery performance across device designs. HeLa cells were treated by 4 different device designs to deliver: (a) cascade blue conjugated 3 kDa dextran, (b) fluorescein conjugated 70 kDa dextran, and (c) an APC conjugated IgG1 isotype control antibody. The three materials were delivered simultaneously and the results were measured by flow cytometry. 10-6×5 devices demonstrated the highest delivery efficiency, while 10-7 devices demonstrated the lowest efficiency of the designs tested. Control samples were incubated with the delivery mixture for the duration of the experiment to account for autofluorescence, endocytosis and surface binding of the target materials. The displayed data are obtained from a representative case of our triplicate data set (Fig. S3 and S4, ESI†)."
- The page shows three flow cytometry histograms labeled a), b), c) corresponding to 3 kDa dextran, 70 kDa dextran, and Mouse IgG1 isotype - APC. Legend indicates device types: 10-6×5 (green), 50-6 (black), 10-6 (red), 10-7 (blue), and Control (gray).
- Plain-language description of Figure 2:
- What is drawn: three flow cytometry histograms plotting fluorescence intensity (x-axis) vs. percent of cells (y-axis) for each delivery material; multiple colored curves represent different device designs and a control.
- What is compared: delivery performance across four device designs for three cargo sizes (3 kDa, 70 kDa dextran, and antibody). The histograms compare the distribution of fluorescence intensities achieved with each device.
- What the result shows: the 10-6×5 device produced the highest delivery (histogram shifted toward higher fluorescence) for all three cargos, whereas the 10-7 device produced the lowest. This indicates device geometry (constriction length/number) affects delivery efficiency.
- How the depicted process works: as cells pass through different constriction designs, they experience varying mechanical deformation; more or repeated constrictions (10-6×5) lead to increased membrane permeabilization and thus higher uptake of fluorescent cargo, measured as increased intracellular fluorescence by flow cytometry.
- Text continuing: They interpret these data to support calcium dependence (referencing Fig. 3).
Figure 3 (page 4, right column)
- Caption (transcribed):
- "Fig. 3 Delivery by cell squeezing is calcium dependent. (a) Representative images from cells treated by a 50-6 device. Images were obtained on the day of treatment. Intracellular delivery of 3 kDa Alexa Fluor 488 conjugated dextran and 10 kDa tetramethyl rhodamine conjugated dextran was measured by fluorescence microscopy. The PBS + Ca buffer consisted of PBS supplemented with 1.8 mM of calcium. Scale bars are 200 µm. (b) Normalized delivery intensity of HeLa cells treated in different buffers. Experiments were conducted in PBS, PBS + Ca, and Dulbecco's modified eagle medium (DMEM). Corresponding viability data are presented in Fig. S6 (ESI†). (c) Normalized delivery intensity of HeLa cells treated in PBS containing different concentrations of calcium. The experiments were conducted across different operating pressures to confirm that the results were consistent across conditions. The mean intensity of cascade blue conjugated 3 kDa dextran was measured by flow cytometry and normalized against the control to account for background effects (e.g. endocytosis and surface binding). Error bars represent 2 standard deviations among triplicates."
- Visual elements:
- (a) A set of three image panels labeled "Bright Field", "Alexa 488 3kDa Dextran" and "Rhodamine 10kDa Dextran". Two rows: top row labeled "PBS" shows bright field and fluorescence images, bottom row labeled "PBS + Ca" likewise. In images, PBS samples show abundant green and red intracellular fluorescence; PBS + Ca samples show less.
- (b) A small plot of normalized mean intensity vs. operating pressure? The parsed text references buffer comparisons. There's an accompanying small graph with points and error bars.
- (c) A plot of normalized delivery intensity vs. calcium concentration at various pressures, showing decreased delivery with increasing calcium.
- Plain-language description of Figure 3:
- What is drawn: (a) microscopy images comparing cells treated without and with calcium in buffer, showing fluorescence of delivered 3 kDa and 10 kDa dextrans; (b) bar/point plot comparing normalized delivery intensity in PBS, PBS+Ca, and DMEM; (c) plot showing how normalized delivery intensity changes with calcium concentration for multiple operating pressures.
- What is compared: delivery in buffers lacking calcium vs. buffers with physiological calcium (1.8 mM) and in culture medium; also delivery across a range of calcium concentrations and pressures.
- What the result shows: cells treated in PBS (no added calcium) show higher intracellular fluorescence (higher uptake) than cells treated in PBS with 1.8 mM calcium or DMEM. Increasing calcium concentration reduces delivery in a dose-dependent manner. This supports calcium-dependent membrane repair limiting uptake.
- How the depicted process works: when cells are mechanically disrupted, in the absence of extracellular calcium the membrane remains open longer, allowing more uptake of dextran; in presence of calcium, active membrane repair mechanisms close membrane pores faster, reducing uptake.
Page 5 — Membrane recovery kinetics and Figures 4 & 5 (visual reading order)
- Subsection "Membrane recovery kinetics"
- They examined rate of repair in different buffers. Because treatment duration for a sample is 0.5–10 s, they could follow-up soon after membrane disruption. Cells were treated by device in absence of dextran, subsequently exposed to dextran at defined times. Intensity of dextran fluorescence correlates to extent of membrane disruption that persisted. Data show cells treated in presence of calcium seal membranes within 15–30 s; those in PBS alone are not fully closed even 3 min after treatment (Fig. 4a and b). This delay could account for delivery efficiency differences observed earlier (Fig. 3) and observed in both 10-6 and 50-6 designs (Fig. 4c).
- Low temperature (on ice) retards membrane repair relative to ambient (Fig. S9). Similar calcium and temperature dependence observed in primary naïve T cells (Fig. 5a and b). These findings enabled development of protocols delivering antibodies to primary naïve T cells with up to 54% efficiency while maintaining 56% viability (Fig. 5c and Fig. S12).
Figure 4 (page 5)
- Caption transcribed:
- "Fig. 4 Pore closure kinetics are calcium dependent. (a) Normalized intensity of HeLa cells treated in the absence of dyes and subsequently exposed to cascade blue conjugated 3 kDa dextran at the specified time points. PBS, PBS supplemented with 1.8 mM of calcium, and (b) DMEM were used as buffers during these experiments. (c) Treatment of HeLa cells by a 50-6 and a 10-6 device is also compared in a PBS buffer. The mean intensity of cascade blue conjugated 3 kDa dextran was measured by flow cytometry and normalized against the control to account for background effects (e.g. endocytosis and surface binding). Error bars represent 2 standard deviations among triplicates. Corresponding viability data are presented in Fig. S8 (ESI†)."
- Visual elements:
- (a) A plot of Normalized Mean Intensity vs Time Post-Treatment (minutes) showing three series: PBS (open squares), PBS+Ca (red circles), Control (gray?) with intensity on y-axis decreasing over time; PBS+Ca curve near baseline after ~1 min; PBS remains higher for several minutes.
- (b) A similar plot for DMEM and possibly PBS vs time showing faster closure in DMEM.
- (c) A plot comparing 50-6 device and 10-6 device in PBS plotting normalized mean intensity vs Time Post-Treatment showing both decay curves; 50-6 (pink) shows higher initial intensity than 10-6 (green) but both decline over time; control baseline near zero.
- Plain-language description of Figure 4:
- What is drawn: time-course plots of normalized intracellular fluorescence intensity after cells are treated and then exposed to dye at various times post-treatment; separate plots for PBS, PBS+Ca, DMEM, and device designs.
- What is compared: how fast membrane pores close (inferred from uptake of dye introduced at various times) in buffers with and without calcium, in culture medium, and across device types.
- What the result shows: in PBS+Ca and DMEM, normalized uptake is low if dye added beyond ~15–30 s, indicating rapid sealing; in PBS without calcium, uptake persists for minutes indicating slow sealing. Different device designs give different starting uptake magnitudes but the calcium-dependent closure kinetics persist across designs.
- How the process works: when mechanical disruption occurs, extracellular calcium triggers active membrane repair that closes pores within tens of seconds; without calcium, pores remain open longer allowing dye uptake introduced up to minutes later.
Figure 5 (page 5)
- Caption transcribed:
- "Fig. 5 Translation to primary naïve murine T cells. Naïve murine T cells were treated by a 30-4 device in the absence of dyes and subsequently exposed to cascade blue conjugated 3 kDa dextran at the specified times. (a) PBS and (b) PBS supplemented with 1.8 mM of calcium were used as delivery buffers to compare membrane recovery kinetics. (c) Delivery of APC conjugated IgG1 isotype control antibodies to naïve murine T cells by a 30-4 device run on ice. Control samples were incubated with the delivery mixture for the duration of the experiment to account for autofluorescence, endocytosis and surface binding of the target materials. The displayed data were obtained from a representative case of our triplicate data set by flow cytometry (Fig. S10, ESI†)."
- Visual elements:
- (a) histogram (flow cytometry) showing 3 kDa dextran uptake at time points 0s, 15s, 1 min, and Control for PBS; curves of different colors indicate time points, with 0s highest and later times lower.
- (b) similar histogram for PBS+Ca with time points showing much lower uptake across times, validating faster recovery.
- (c) histogram of Mouse IgG1 isotype - APC showing results for 30-4 device vs Control while run on ice; treated sample shows increased antibody fluorescence relative to control.
- Plain-language description of Figure 5:
- What is drawn: flow cytometry histograms of naïve murine T cells showing intracellular uptake of 3 kDa dextran when dye added at different times after treatment in PBS or PBS+Ca; and antibody delivery when device run on ice.
- What is compared: membrane recovery kinetics in primary T cells in PBS vs PBS+Ca, and delivery of antibody when treating cells on ice.
- What the result shows: similar calcium dependence in primary T cells as seen in HeLa: in PBS (no calcium) dye uptake persists at later time points whereas in PBS+Ca uptake is limited to short times after treatment; running the device on ice enabled antibody delivery to naïve T cells (delivery observed) with stated efficiencies in text.
- How the process works: same mechanism — mechanical disruption allows uptake; extracellular calcium and temperature influence active repair kinetics, which in turn control how long membrane remains permeable and thus how much material enters.
Page 5 — Conclusions and final text (visual reading order)
- Paragraphs transcribed:
- They describe development of new generation devices with higher throughput (~6×) and more uniform treatment (Fig. 1, Fig. S1 and Table S1). These devices were used to characterize membrane disruption/repair dependence on constriction geometry, flow rate, and buffer composition. Calcium identified as important parameter mediating membrane repair; disruptions generated by this technique likely >200 nm in size (citing Fig. 3). Characterization of kinetics of delivery and membrane repair offers insight into other physical approaches (ultrasound, fluid shear, nanowire-based). The calcium composition of buffer (Fig. 3), temperature (Fig. S9 and S11), and incubation time post-treatment (Fig. 4) are important determinants of treatment efficacy. Insights helped evolve technique to deliver protein to T cells (Fig. 5). Consistency across HeLa and naïve T cells suggests parameters relevant to broad cell types.
- Final concluding paragraph:
- "Our work highlights the importance of membrane recovery and how careful manipulation of delivery conditions can improve performance without sacrificing cell viability. The described experiments also underscore the potential utility of this approach in studying membrane repair kinetics and its associated pathways, such as vesicular exocytosis,30 to better understand repair mechanisms in healthy and diseased cells. Future work with this platform could help elucidate the potential role of other ions and proteins, such as magnesium and calmodulin,31 through siRNA gene knockdown, antibody-based pathway inhibition, and buffer composition studies. A deeper understanding of the membrane repair process could potentially enable the design of more effective delivery methods and thus help overcome some of the challenges of intracellular delivery in both research and clinical applications."
- Conflict of interest:
- "A.S., R.L., and K.F.J. have a financial interest in proprietary mechanoporation platform."
- Acknowledgements:
- Funding sources: National Institutes of Health Grants RC1 EB011187-02 and R01GM101420-01A1, Kathy and Curt Marble Cancer Research Fund, National Cancer Institute Cancer Center Support (Core) Grants P30-CA14051 and MPP-09Call-Langer-60.
- Notes and references:
- The reference list is present (numbered 1–31). I will not read the entire reference list aloud beyond acknowledging its presence. (References visible include literature on nanoparticles, electroporation, membrane repair, and related techniques.)
Additional visual items
- Several supplementary figure references are present (Fig. S1–S12, ESI) but the actual supplementary figures are not within the provided pages. The main figures included are Fig. 1, Fig. 2, Fig. 3, Fig. 4, and Fig. 5 — all described above.
End of transcription.
If you would like, I can:
- Read back any specific figure in more verbal detail (for example, list axis labels and approximate numerical ranges from a given graph), or
- Provide a concise plain-language summary of the main findings and their implications strictly as written in the document.
## Source note
The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.