Publication · 2015 · PLOS ONE

Ex Vivo Cytosolic Delivery of Functional Macromolecules to Immune Cells

Armon Sharei, Radiana Trifonova, Siddharth Jhunjhunwala

Cells
B cells, T cells, Monocytes, Dendritic Cells, Treg
Cargos
Polymers, siRNA, Antibody

What this document says

This paper describes the adaptation and testing of a vector-free microfluidic intracellular delivery platform (proprietary mechanoporation platform) for ex vivo cytosolic delivery of diverse macromolecules into primary murine and human immune cells. Cells flow through parallel microfluidic channels and are rapidly deformed at constrictions, producing transient membrane disruption that permits macromolecules present in the surrounding buffer (dextrans, antibodies, siRNA, proteins) to enter the cytosol before membrane repair. Device geometry, temperature, buffer composition, and flow speed (pressure) were varied to optimize delivery efficiency and viability. The platform delivered dextrans, antibodies and siRNAs to T cells, B cells, monocytes/macrophages and monocyte-derived dendritic cells, achieved target-specific protein knockdown, compared favorably to nucleofection with higher viability and reduced nonspecific effects, and reduced HIV infection in CD4+ T cells when antiviral siRNAs were delivered prior to infection.

Introduction

The authors motivate the need for efficient, nontoxic methods to deliver macromolecules to primary immune cells, noting limitations of electroporation, viral vectors, cell-penetrating peptides, and nanoparticle approaches that mainly result in endosomal uptake. They propose adapting a previously described vector-free microfluidic membrane disruption approach for immune cells, where rapid mechanical deformation in microfluidic constrictions transiently disrupts the membrane, allowing cytosolic entry of macromolecules present in the buffer and subsequent membrane resealing within minutes.

Results and Discussion

Microfluidic devices with 45–75 parallel channels and varying constriction lengths, widths and numbers were fabricated and operated using a pressure-driven reservoir system. Delivery performance was assayed using fluorescently labeled 3 kDa and 70 kDa dextrans and antibodies in mouse and human immune cell types. A 30–4 device (30 μm length, 4 μm width) was optimal for many lymphoid and myeloid cells. Delivery efficiency increased with narrower/longer constrictions, lower temperature, calcium-free buffers and higher pressures, although these could trade off with viability. siRNA delivery produced target-specific protein knockdown in T cells and MDDCs lasting ~10 days in T cells; device-mediated knockdown was comparable to nucleofection but with higher viability, less nonspecific knockdown and better long-term survival. Delivery of siRNAs targeting CD4, vif or gag reduced HIV infection (p2

Materials and Methods

The proprietary mechanoporation platform platform comprises a silicon-glass microfluidic chip with parallel channels and constrictions, a reservoir system to load and collect cell suspensions mixed with delivery materials, and a pressure regulation system to drive flow. Typical workflow: mix cells and payload, pressurize the reservoir to drive flow through the chip, collect cells, incubate (often on ice) for ~5 minutes to allow membrane recovery, then process. Devices and equipment were obtained from proprietary mechanoporation platform and used per manufacturer protocols. Operational variables (device geometry, temperature, buffer, pressure) were adjusted per cell type. Mouse and human primary cells were isolated using standard procedures described for spleen-derived mouse T/B cells, peritoneal macrophages, and human PBMC-derived cells.

What the figures show

  • Figure 1: A multi-panel figure illustrating the device and delivery performance in mouse cells. Panel A is a schematic of the device design and delivery mechanism showing parallel microfluidic channels with constrictions; labels indicate fluid speed (V), constriction width (W) and length (L), and depict cells undergoing rapid deformation, transient membrane disruption, and subsequent recovery. Panel B is a cartoon of the experimental setup and procedure with reservoirs, pressure tubing and collection steps. Panel C shows representative flow cytometry histograms for T cells, B cells and CD11b+ myeloid cells comparing untreated, incubated-with-material-but-no-device, and device-treated samples delivering APC-labeled IgG1. Panel D presents bar graphs (mean ± SD, n=3) of percent-positive cells for delivery of 3 kDa dextran, 70 kDa dextran and APC-IgG1 across cell types; dead cells were excluded by propidium iodide. The figure compares untreated, no-device controls and device-treated samples and shows substantially higher delivery for device-treated cells, supporting that mechanical deformation in microfluidic constrictions enables cytosolic delivery of macromolecules.
  • Figure 2: A composite figure showing delivery to human immune cells and functional outcomes. Panel A contains representative flow histograms and replicate data across device designs for human T cells (30–4 device) and MDDCs (10–7 device) delivering 3 kDa and 70 kDa dextrans and APC-IgG1. Panel B shows siRNA-mediated knockdown of CD4 in CD4+ T cells and DC-SIGN in MDDCs (flow cytometry and/or qRT-PCR results). Panel C shows knockdown of CD4 in human regulatory T cells after treatment with a 30–4 device. Panel D compares device-mediated siRNA delivery to nucleofection (Amaxa) in T cells, reporting protein expression 72 hours post-delivery and cell viability after treatment, indicating similar knockdown but higher viability with the device. Panel E shows intracellular p24 antigen staining histograms used to assess HIV infection levels after various siRNA pretreatments (control siRNA, CD4 siRNA, vif siRNA, gag siRNA, vif+gag siRNA); siRNAs targeting viral genes or CD4 were delivered prior to infection. Panel F plots median fluorescence intensity of p24 across repeats (minimum n=4) with mean + standard error, showing reduced p24 signal when antiviral or CD4-targeting siRNAs were delivered, indicating decreased HIV infection/replication.
  • Figure (schematics in Methods): Diagrams and workflow illustrations of the proprietary mechanoporation platform platform and operating procedure. These images depict the three main components (silicon-glass microfluidic chip with parallel channels and constrictions, reservoir interface for loading/collection, and pressure regulation system), and the experimental workflow: mixing cells with delivery material, loading into reservoir, pressurizing to initiate flow through the chip, collecting treated cells, and incubating on ice for ~5 minutes to permit membrane recovery before further processing.

The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.

This publication refers to SQZ Biotechnologies, a separate company previously founded by Dr. Armon Sharei. Dr. Sharei founded Portal Biotechnologies (Watertown, MA), which is develops the next generation of the platform technology mentioned in this publication.