May Tun Saung, Armon Sharei, Viktor A. Adalsteinsson, Nahyun Cho, Tushar Kamath, Camilo Ruiz, Jesse Kirkpatrick, Nehal Patel, Mari Mino-Kenudson, Sarah P. Thayer, Robert Langer, Klavs F. Jensen, Andrew S. Liss, J. Christopher Love
- Cells
- PBMCs, Cancer Cell Lines
- Cargos
- Polymers, Antibody
What this document says
This document describes a microfluidic, high-throughput delivery platform that uses size-dependent mechanical deformation to transiently disrupt cell membranes and enable selective cytosolic delivery of macromolecular cargo. Chips contain 75 parallel channels each with a central constriction whose width (4–9 µm) and applied pressure determine delivery efficiency and viability; optimal constriction widths differ by cell type according to average cell diameter. The platform selectively labels larger cells within heterogeneous mixtures (e.g., pancreatic cancer cell lines versus primary human T-cells) and was applied to enrich and genomically characterize circulating tumor cells from spiked blood and from a pancreatic cancer patient sample.
Abstract
A microfluidic device exploits small differences in cell diameter to achieve selective intracellular delivery by transient membrane disruption as cells transit a constriction. Constriction widths are tuned to preferentially deliver cargo to cells of a given size (e.g., 4 µm for primary human T-cells averaging 6.7 µm, 6–7 µm for larger pancreatic cancer cell lines BxPc3 and PANC-1). The method enables selective labeling of tumor cells within heterogeneous mixtures and was used to tag and isolate circulating tumor cells from patient blood for genomic characterization.
1. Introduction
The document frames the need to identify and manipulate subpopulations within heterogeneous tissues without relying on surface markers or genetic reporters. It notes existing physical-property–based isolation methods and presents the concept of using a mechanical membrane disruption approach in a microfluidic device to enable cytosolic delivery independent of endocytosis or surface interactions. The approach aims to reduce marker-based bias and permit selective tagging based on size.
2. Results
Results show that delivery depends on the relationship between cell diameter and constriction width. Devices with 75 parallel channels and central constrictions of defined widths were used to pass suspensions containing fluorescently labeled dextran. Delivery and viability were measured by FACS and PI staining, demonstrating that constrictions several micrometers smaller than the cell diameter produced maximal delivery but that excessively narrow constrictions decreased viability. Delivery efficacy (delivery % × viability %) was used to identify optimal constrictions (4 µm for T-cells; 6–7 µm for BxPc3 and PANC-1), and higher applied pressure increased delivery but reduced viability. In mixed suspensions (T-cells + GFP PANC-1), larger cells showed much higher delivery at their optimal constriction widths; delivery to T-cells was reduced when mixed with PANC-1, possibly due to altered flo
2.1. Delivery Approach
The microfluidic chips have 75 parallel silicon channels sealed with Pyrex, each containing a central constriction of specified length and width. Cells in suspension mixed with fluorophore-conjugated dextran are driven through constrictions; mechanical deformation during transit transiently disrupts membranes allowing cytosolic diffusion of cargo. The degree of deformation—and thus delivery and viability—is a function of cell diameter relative to constriction width, and delivery efficacy varies with applied pressure.
2.2. Selective Delivery to Circulating Tumor Cells
Whole blood spiked with GFP-expressing PANC-1 cells was RBC-depleted, mixed with tetramethylrhodamine-conjugated dextran, and processed through chips with 7 µm constrictions. Cells were counterstained with anti-CD45 and sorted by FACS using high-dextran/low-CD45 gates; most dextran-high, CD45-low cells were GFP-positive tumor cells with high specificity (75% at low spike-in, 92% at high spike-in). Targeted sequencing of recovered cells detected PANC-1–specific KRAS and TP53 mutations. Processing of PDAC patient blood and subsequent sorting yielded rhodamine-positive cells harboring a TP53 (R209Q) mutation that matched the primary tumor.
3. Discussion
The document emphasizes that cell size can be used as a physical property to enable selective cytosolic delivery in heterogeneous populations, avoiding dependence on surface markers. The platform can deliver a wide range of cargo sizes directly to the cytosol, which may avoid endosomal degradation. Limitations discussed include possible nuclear membrane disruption in some microfluidic systems (not observed here), temporary diversion of membrane-repair pathways, inability to differentiate subpopulations with very small diameter differences, and the constraint that only the larger population in a mixture can be selectively targeted without lysing larger cells when aiming at smaller ones.
What the figures show
- Figure 1 shows a schematic of the microfluidic delivery platform: each silicon chip contains 75 parallel channels, each channel having a central constriction 10 µm long with widths varying from 4 to 9 µm. The illustration depicts cells transiting a single channel: when a cell passes through a suitably sized constriction it undergoes transient membrane disruption allowing intracellular diffusion of material (green cell). If the constriction is too narrow for the cell, the cell is killed (purple cell). If the constriction is too wide, insufficient deformation occurs and no delivery is achieved (brown cell).
- Figure 2 presents cell size–specific delivery data. Panel A compares diameters of three cell types (T-cells ~6.7 µm, BxPc3 ~10.8 µm, PANC-1 ~12.3 µm). Panel B shows percent delivery and viability for each cell type across constriction widths at 100 psi (averages ± SD from 3–5 experiments). Panel C shows delivery efficacy (delivery % × viability %) for PANC-1 across constriction width and pressure. Panel D is a heat map of delivery efficacy for single-cell-type suspensions across constriction widths at 50 and 100 psi (darker = higher efficacy). Panel E shows flow cytometry of a T-cell + PANC-1 mixture incubated with dextran dye without processing (negative control) and after processing through a 6 µm constriction at 100 psi, demonstrating selective dextran uptake by larger cells. Panel F quantifies percent delivery in mixed T-cell + GFP PANC-1 suspensions across constriction widths at 100 psi (averages ± SD, n=3).
- Figure 3 outlines selective labeling of blood spiked with tumor cells. Panel A is a schematic: GFP PANC-1 cells are spiked into whole blood, RBCs lysed, the sample is delivered through the device with tetramethylrhodamine-dextran, then cells are counterstained with anti-CD45 and GFP-positive CD45-negative cells are isolated by FACS. Panel B shows a FACS plot from a high-concentration spike (2000 cells/mL): P4 gate (high rhodamine, low CD45) is used to sort candidate CTCs and P5 gate (high GFP, low CD45) to sort GFP-expressing PANC-1 cells. Light-blue dots in both gates are true positives (cells positive for both GFP and rhodamine); 92% of P4 cells are accurate hits. In this experiment, 227 GFP-expressing PANC-1 cells were isolated from about 1.2 million viable cells.
- Figure 4 shows isolation of a patient’s PDAC cells. Panel A provides histopathology confirming pancreatic ductal adenocarcinoma in the primary tumor (sample HTB1760). Panel B reports the frequency of a TP53 mutation (R209Q) identified in DNA from the tumor, from high- and low-purity FACS-purified rhodamine-positive CTCs recovered after delivery, and from matched germline DNA, demonstrating the mutation in tumor and recovered CTC samples but not in germline DNA.
The summary and sections were written from the public full text of the linked paper. They are not a word-for-word extract.
This publication refers to SQZ Biotechnologies, a separate company previously founded by Dr. Armon Sharei. Dr. Sharei founded Portal Biotechnologies (Watertown, MA), which is develops the next generation of the platform technology mentioned in this publication.
# A Size‐Selective Intracellular Delivery Platform
This page is a text version of a Portal Biotechnologies publication. The bibliographic record is labeled in the text so it can be read without the surrounding website.
## Bibliographic record
- Title: A Size‐Selective Intracellular Delivery Platform
- Document type: Publication
- Year: 2016
- Outlet: WILEY
- Cells: PBMCs, Cancer Cell Lines
- Cargos: Polymers, Antibody
- Page URL: https://portal.bio/publications/2016-a-size-selective-intracellular-delivery-platform--ajkHOhEAACoAc-EA
- Markdown URL: https://portal.bio/publications/2016-a-size-selective-intracellular-delivery-platform--ajkHOhEAACoAc-EA.md
- External publication: https://onlinelibrary.wiley.com/doi/abs/10.1002/smll.201601155
## Portal description
May Tun Saung, Armon Sharei, Viktor A. Adalsteinsson, Nahyun Cho, Tushar Kamath, Camilo Ruiz, Jesse Kirkpatrick, Nehal Patel, Mari Mino-Kenudson, Sarah P. Thayer, Robert Langer, Klavs F. Jensen, Andrew S. Liss, J. Christopher Love
## Summary
This document describes a microfluidic, high-throughput delivery platform that uses size-dependent mechanical deformation to transiently disrupt cell membranes and enable selective cytosolic delivery of macromolecular cargo. Chips contain 75 parallel channels each with a central constriction whose width (4–9 µm) and applied pressure determine delivery efficiency and viability; optimal constriction widths differ by cell type according to average cell diameter. The platform selectively labels larger cells within heterogeneous mixtures (e.g., pancreatic cancer cell lines versus primary human T-cells) and was applied to enrich and genomically characterize circulating tumor cells from spiked blood and from a pancreatic cancer patient sample.
## Sections
### Abstract
A microfluidic device exploits small differences in cell diameter to achieve selective intracellular delivery by transient membrane disruption as cells transit a constriction. Constriction widths are tuned to preferentially deliver cargo to cells of a given size (e.g., 4 µm for primary human T-cells averaging 6.7 µm, 6–7 µm for larger pancreatic cancer cell lines BxPc3 and PANC-1). The method enables selective labeling of tumor cells within heterogeneous mixtures and was used to tag and isolate circulating tumor cells from patient blood for genomic characterization.
### 1. Introduction
The document frames the need to identify and manipulate subpopulations within heterogeneous tissues without relying on surface markers or genetic reporters. It notes existing physical-property–based isolation methods and presents the concept of using a mechanical membrane disruption approach in a microfluidic device to enable cytosolic delivery independent of endocytosis or surface interactions. The approach aims to reduce marker-based bias and permit selective tagging based on size.
### 2. Results
Results show that delivery depends on the relationship between cell diameter and constriction width. Devices with 75 parallel channels and central constrictions of defined widths were used to pass suspensions containing fluorescently labeled dextran. Delivery and viability were measured by FACS and PI staining, demonstrating that constrictions several micrometers smaller than the cell diameter produced maximal delivery but that excessively narrow constrictions decreased viability. Delivery efficacy (delivery % × viability %) was used to identify optimal constrictions (4 µm for T-cells; 6–7 µm for BxPc3 and PANC-1), and higher applied pressure increased delivery but reduced viability. In mixed suspensions (T-cells + GFP PANC-1), larger cells showed much higher delivery at their optimal constriction widths; delivery to T-cells was reduced when mixed with PANC-1, possibly due to altered flo
### 2.1. Delivery Approach
The microfluidic chips have 75 parallel silicon channels sealed with Pyrex, each containing a central constriction of specified length and width. Cells in suspension mixed with fluorophore-conjugated dextran are driven through constrictions; mechanical deformation during transit transiently disrupts membranes allowing cytosolic diffusion of cargo. The degree of deformation—and thus delivery and viability—is a function of cell diameter relative to constriction width, and delivery efficacy varies with applied pressure.
### 2.2. Selective Delivery to Circulating Tumor Cells
Whole blood spiked with GFP-expressing PANC-1 cells was RBC-depleted, mixed with tetramethylrhodamine-conjugated dextran, and processed through chips with 7 µm constrictions. Cells were counterstained with anti-CD45 and sorted by FACS using high-dextran/low-CD45 gates; most dextran-high, CD45-low cells were GFP-positive tumor cells with high specificity (75% at low spike-in, 92% at high spike-in). Targeted sequencing of recovered cells detected PANC-1–specific KRAS and TP53 mutations. Processing of PDAC patient blood and subsequent sorting yielded rhodamine-positive cells harboring a TP53 (R209Q) mutation that matched the primary tumor.
### 3. Discussion
The document emphasizes that cell size can be used as a physical property to enable selective cytosolic delivery in heterogeneous populations, avoiding dependence on surface markers. The platform can deliver a wide range of cargo sizes directly to the cytosol, which may avoid endosomal degradation. Limitations discussed include possible nuclear membrane disruption in some microfluidic systems (not observed here), temporary diversion of membrane-repair pathways, inability to differentiate subpopulations with very small diameter differences, and the constraint that only the larger population in a mixture can be selectively targeted without lysing larger cells when aiming at smaller ones.
## What the figures show
- Figure 1 shows a schematic of the microfluidic delivery platform: each silicon chip contains 75 parallel channels, each channel having a central constriction 10 µm long with widths varying from 4 to 9 µm. The illustration depicts cells transiting a single channel: when a cell passes through a suitably sized constriction it undergoes transient membrane disruption allowing intracellular diffusion of material (green cell). If the constriction is too narrow for the cell, the cell is killed (purple cell). If the constriction is too wide, insufficient deformation occurs and no delivery is achieved (brown cell).
- Figure 2 presents cell size–specific delivery data. Panel A compares diameters of three cell types (T-cells ~6.7 µm, BxPc3 ~10.8 µm, PANC-1 ~12.3 µm). Panel B shows percent delivery and viability for each cell type across constriction widths at 100 psi (averages ± SD from 3–5 experiments). Panel C shows delivery efficacy (delivery % × viability %) for PANC-1 across constriction width and pressure. Panel D is a heat map of delivery efficacy for single-cell-type suspensions across constriction widths at 50 and 100 psi (darker = higher efficacy). Panel E shows flow cytometry of a T-cell + PANC-1 mixture incubated with dextran dye without processing (negative control) and after processing through a 6 µm constriction at 100 psi, demonstrating selective dextran uptake by larger cells. Panel F quantifies percent delivery in mixed T-cell + GFP PANC-1 suspensions across constriction widths at 100 psi (averages ± SD, n=3).
- Figure 3 outlines selective labeling of blood spiked with tumor cells. Panel A is a schematic: GFP PANC-1 cells are spiked into whole blood, RBCs lysed, the sample is delivered through the device with tetramethylrhodamine-dextran, then cells are counterstained with anti-CD45 and GFP-positive CD45-negative cells are isolated by FACS. Panel B shows a FACS plot from a high-concentration spike (2000 cells/mL): P4 gate (high rhodamine, low CD45) is used to sort candidate CTCs and P5 gate (high GFP, low CD45) to sort GFP-expressing PANC-1 cells. Light-blue dots in both gates are true positives (cells positive for both GFP and rhodamine); 92% of P4 cells are accurate hits. In this experiment, 227 GFP-expressing PANC-1 cells were isolated from about 1.2 million viable cells.
- Figure 4 shows isolation of a patient’s PDAC cells. Panel A provides histopathology confirming pancreatic ductal adenocarcinoma in the primary tumor (sample HTB1760). Panel B reports the frequency of a TP53 mutation (R209Q) identified in DNA from the tumor, from high- and low-purity FACS-purified rhodamine-positive CTCs recovered after delivery, and from matched germline DNA, demonstrating the mutation in tumor and recovered CTC samples but not in germline DNA.