Xiaoyun Ding, Martin P. Stewart, Armon Sharei, James C. Weaver, Robert S. Langer & Klavs F. Jensen
- Cells
- Cancer Cell Lines
- Cargos
- Polymers, mRNA, Protein, Antibody, DNA
What this document says
This paper describes a microfluidic device that combines rapid mechanical membrane disruption (cell squeezing) with a downstream electric-field zone to enable fast, high-throughput nuclear delivery of plasmid DNA. Cells are forced through micron-scale constrictions to transiently disrupt the plasma membrane, then exposed to electrical pulses that further disrupt the nuclear envelope and electrophoretically drive DNA into the cytoplasm and nucleus. The combined disruption-and-field-enhanced (DFE) approach yields rapid GFP expression (most transfected cells show expression within 1 hour), high transfection efficiencies at lower applied voltages than flow electroporation, and throughputs up to hundreds of thousands to millions of cells per minute per device, while nuclear and plasma membranes recover within minutes via ESCRT-mediated repair.
Abstract
The authors present a device integrating microfluidic constrictions and microelectrodes to combine mechanical disruption of the plasma membrane with subsequent electric pulses that drive DNA into the cytoplasm and nucleus. They report nuclear delivery of plasmid DNA with detectable expression within 1 hour after treatment and high throughput (up to millions of cells per minute per device). Nuclear envelope integrity is shown to recover within 15 minutes by tracking ESCRT-III protein CHMP4B. The approach is compared with chemical transfection, conventional electroporation, and manual injection.
DFE Design and Characterization
Devices comprise many parallel constriction channels etched in silicon bonded to Pyrex patterned with electrodes. Constriction widths and lengths were chosen in ranges previously effective for mechanical disruption (4–10 μm width, 10–30 μm length) and electrode geometries produced ~2 kV/cm with low applied voltage. Electrical pulses had durations 50–500 μs and duty cycles 1%–10%. Typical operation used 100,000–500,000 cells/s per chip with exposure times in the electrical field of about 10–100 ms. Transfection of HeLa cells with GFP plasmid showed >60% and >90% expression as applied amplitude increased to 8 V and 10 V respectively for a 10-6 device, while comparable flow electroporation required higher amplitude (~14 V) for similar expression, indicating mechanical disruption enhances DNA delivery at lower fields with negligible extra viability loss.
DFE versus Microinjection, Flow EP, EP, and Cell Squeezing
The authors compared DFE to microinjection, lipofection (Lipofectamine 2000), flow electroporation (flow EP), and conventional electroporation (NEON). DFE and microinjection produced similar expression kinetics, with >80% of ultimately expressing cells detectable within 1 hour, whereas flow EP and EP had most expression occurring 4–48 hours post treatment and lipofection showed minimal signal in the first 4 hours. Flow cytometry showed DFE had higher uniformity (lower RSD) and higher normalized mean intensity than EP. Visualization of labeled plasmid DNA showed DFE delivered label into cytoplasm and nucleus, while EP showed DNA accumulation at the plasma membrane and squeezing alone showed no detectable labeled DNA inside cells.
Visualization of DNA and ESCRT-III Recruitment
Confocal imaging with Cy3-labeled plasmid DNA and membrane/nuclear stains found that DFE produced labeled DNA signal in plasma membrane, cytoplasm, and nucleus shortly after treatment, while electroporation produced membrane-localized DNA spots and squeezing alone gave no intracellular label. Using HeLa cells expressing CHMP4B-GFP, the authors observed transient CHMP4B foci at both plasma membrane and nuclear envelope after DFE, but only at plasma membrane after squeezing or EP, indicating reversible disruption and ESCRT-mediated repair of both membranes with DFE and that nuclear envelope repair occurred within minutes.
Discussion
The DFE approach combines mechanical disruption and electrical driving forces to facilitate rapid nuclear access of plasmid DNA in large numbers of cells. The method reduces required electrical amplitude compared with flow electroporation, achieves rapid expression kinetics similar to microinjection, and yields high throughput. The performance depends on multiple interacting parameters (cell speed, constriction geometry, pulse profile, buffer), and hypo-osmolar buffers were used to balance mechanical and electrical compatibility. Limitations include interdependence of mechanical disruption and electrical exposure (higher speed reduces electrical exposure) and device clogging after multiple uses.
What the figures show
- Fig. 1 shows the device structure and working mechanism. Panel (a) is a schematic of the two-step process: (i) cells are mechanically disrupted as they pass through microfluidic constrictions smaller than the cell diameter, transiently permeabilizing the plasma membrane; (ii) downstream electric pulses are applied to further disrupt the nuclear envelope and drive DNA into the cytoplasm and nucleus through the disrupted membranes. Panel (b) shows a magnified view of parallel microfluidic constrictions etched into a silicon wafer (left) and a Pyrex wafer with deposited electrodes (right). Panel (c) is an optical image of a finished device after bonding silicon and Pyrex wafers; a 1 mm scale bar is provided.
- Fig. 2 presents DNA transfection performance and expression dynamics as functions of applied electric field and method. Panels (a) and (b) show GFP transfection efficiency and cell viability at 24 h versus applied voltage: mechanical disruption prior to electrical delivery (DFE) significantly increases transfection at lower voltages while causing negligible additional viability loss compared with flow electroporation. Panel (c) shows GFP expression efficiency over time post treatment for DFE (10-7 chip), flow EP (0.1 ms/10 V pulses at 200 Hz), and EP (single 15 ms/15000 V pulse), highlighting that DFE produces earlier expression. Panel (d) quantifies expression timing: more than 80% of transfected cells expressed GFP within 1 h after microinjection and DFE, whereas most transfected cells in flow EP, EP, and Lipofectamine express between 4–48 h; cell counts for each method indicate relative throughput. Data points are triplicates with ± s.d.
- Fig. 3 visualizes labeled plasmid DNA delivery to HeLa cells using confocal imaging after nucleus and plasma membrane staining and mixing with Cy3-labeled DNA. Panel (a) shows that squeezing alone (10-7 chip at 500 mm/s) produced no detectable intracellular labeled DNA. Panel (b) shows conventional electroporation (NEON, 15 ms/1200 V) led to DNA accumulation at the plasma membrane as bright localized spots. Panel (c) shows DFE (10-7 chip at 500 mm/s with 0.1 ms pulses at 200 Hz and 10 V) produced substantial Cy3 fluorescence distributed in plasma membrane, cytoplasm, and nucleus. Panel (d) plots relative fluorescence intensity across single cells for the three treatments, demonstrating different DNA distributions: no intracellular signal for squeezing, membrane-localized peaks for EP, and nuclear plus cytoplasmic signal for DFE. Scale bar = 10 μm; original confocal images are provided.
- Fig. 4 examines ESCRT-III (CHMP4B-GFP) recruitment for plasma membrane and nuclear envelope repair after treatments. HeLa cells expressing CHMP4B-GFP were fixed at multiple time points (0.5–15 minutes) post treatment with squeezing, EP, or DFE and imaged. Panel (a) shows representative confocal images at 1.5 minutes: CHMP4B-GFP foci are visible at both plasma membrane and nuclear envelope after DFE but only at plasma membrane after squeezing and EP. Panels (b) and (c) quantify the number of CHMP4B-GFP foci at plasma membrane and nuclear envelope over time for S, EP, and DFE (mean of 10 cells per point ± s.d.), showing transient recruitment consistent with rapid ESCRT-mediated repair.
The summary and sections were written from the public full text of the linked paper. They are not a word-for-word extract.
This publication refers to SQZ Biotechnologies, a separate company previously founded by Dr. Armon Sharei. Dr. Sharei founded Portal Biotechnologies (Watertown, MA), which is develops the next generation of the platform technology mentioned in this publication.
# High-throughput nuclear delivery and rapid expression of DNA via mechanical and electrical cell-membrane disruption
This page is a text version of a Portal Biotechnologies publication. The bibliographic record is labeled in the text so it can be read without the surrounding website.
## Bibliographic record
- Title: High-throughput nuclear delivery and rapid expression of DNA via mechanical and electrical cell-membrane disruption
- Document type: Publication
- Year: 2017
- Outlet: NATURE BME
- Cells: Cancer Cell Lines
- Cargos: Polymers, mRNA, Protein, Antibody, DNA
- Page URL: https://portal.bio/publications/2017-high-throughput-nuclear-delivery-and-rapid-expression-of-dna-via-mechanical-and-elect--ajkHMREAACwAc-Dh
- Markdown URL: https://portal.bio/publications/2017-high-throughput-nuclear-delivery-and-rapid-expression-of-dna-via-mechanical-and-elect--ajkHMREAACwAc-Dh.md
- External publication: https://www.nature.com/articles/s41551-017-0039
## Portal description
Xiaoyun Ding, Martin P. Stewart, Armon Sharei, James C. Weaver, Robert S. Langer & Klavs F. Jensen
## Summary
This paper describes a microfluidic device that combines rapid mechanical membrane disruption (cell squeezing) with a downstream electric-field zone to enable fast, high-throughput nuclear delivery of plasmid DNA. Cells are forced through micron-scale constrictions to transiently disrupt the plasma membrane, then exposed to electrical pulses that further disrupt the nuclear envelope and electrophoretically drive DNA into the cytoplasm and nucleus. The combined disruption-and-field-enhanced (DFE) approach yields rapid GFP expression (most transfected cells show expression within 1 hour), high transfection efficiencies at lower applied voltages than flow electroporation, and throughputs up to hundreds of thousands to millions of cells per minute per device, while nuclear and plasma membranes recover within minutes via ESCRT-mediated repair.
## Sections
### Abstract
The authors present a device integrating microfluidic constrictions and microelectrodes to combine mechanical disruption of the plasma membrane with subsequent electric pulses that drive DNA into the cytoplasm and nucleus. They report nuclear delivery of plasmid DNA with detectable expression within 1 hour after treatment and high throughput (up to millions of cells per minute per device). Nuclear envelope integrity is shown to recover within 15 minutes by tracking ESCRT-III protein CHMP4B. The approach is compared with chemical transfection, conventional electroporation, and manual injection.
### DFE Design and Characterization
Devices comprise many parallel constriction channels etched in silicon bonded to Pyrex patterned with electrodes. Constriction widths and lengths were chosen in ranges previously effective for mechanical disruption (4–10 μm width, 10–30 μm length) and electrode geometries produced ~2 kV/cm with low applied voltage. Electrical pulses had durations 50–500 μs and duty cycles 1%–10%. Typical operation used 100,000–500,000 cells/s per chip with exposure times in the electrical field of about 10–100 ms. Transfection of HeLa cells with GFP plasmid showed >60% and >90% expression as applied amplitude increased to 8 V and 10 V respectively for a 10-6 device, while comparable flow electroporation required higher amplitude (~14 V) for similar expression, indicating mechanical disruption enhances DNA delivery at lower fields with negligible extra viability loss.
### DFE versus Microinjection, Flow EP, EP, and Cell Squeezing
The authors compared DFE to microinjection, lipofection (Lipofectamine 2000), flow electroporation (flow EP), and conventional electroporation (NEON). DFE and microinjection produced similar expression kinetics, with >80% of ultimately expressing cells detectable within 1 hour, whereas flow EP and EP had most expression occurring 4–48 hours post treatment and lipofection showed minimal signal in the first 4 hours. Flow cytometry showed DFE had higher uniformity (lower RSD) and higher normalized mean intensity than EP. Visualization of labeled plasmid DNA showed DFE delivered label into cytoplasm and nucleus, while EP showed DNA accumulation at the plasma membrane and squeezing alone showed no detectable labeled DNA inside cells.
### Visualization of DNA and ESCRT-III Recruitment
Confocal imaging with Cy3-labeled plasmid DNA and membrane/nuclear stains found that DFE produced labeled DNA signal in plasma membrane, cytoplasm, and nucleus shortly after treatment, while electroporation produced membrane-localized DNA spots and squeezing alone gave no intracellular label. Using HeLa cells expressing CHMP4B-GFP, the authors observed transient CHMP4B foci at both plasma membrane and nuclear envelope after DFE, but only at plasma membrane after squeezing or EP, indicating reversible disruption and ESCRT-mediated repair of both membranes with DFE and that nuclear envelope repair occurred within minutes.
### Discussion
The DFE approach combines mechanical disruption and electrical driving forces to facilitate rapid nuclear access of plasmid DNA in large numbers of cells. The method reduces required electrical amplitude compared with flow electroporation, achieves rapid expression kinetics similar to microinjection, and yields high throughput. The performance depends on multiple interacting parameters (cell speed, constriction geometry, pulse profile, buffer), and hypo-osmolar buffers were used to balance mechanical and electrical compatibility. Limitations include interdependence of mechanical disruption and electrical exposure (higher speed reduces electrical exposure) and device clogging after multiple uses.
## What the figures show
- Fig. 1 shows the device structure and working mechanism. Panel (a) is a schematic of the two-step process: (i) cells are mechanically disrupted as they pass through microfluidic constrictions smaller than the cell diameter, transiently permeabilizing the plasma membrane; (ii) downstream electric pulses are applied to further disrupt the nuclear envelope and drive DNA into the cytoplasm and nucleus through the disrupted membranes. Panel (b) shows a magnified view of parallel microfluidic constrictions etched into a silicon wafer (left) and a Pyrex wafer with deposited electrodes (right). Panel (c) is an optical image of a finished device after bonding silicon and Pyrex wafers; a 1 mm scale bar is provided.
- Fig. 2 presents DNA transfection performance and expression dynamics as functions of applied electric field and method. Panels (a) and (b) show GFP transfection efficiency and cell viability at 24 h versus applied voltage: mechanical disruption prior to electrical delivery (DFE) significantly increases transfection at lower voltages while causing negligible additional viability loss compared with flow electroporation. Panel (c) shows GFP expression efficiency over time post treatment for DFE (10-7 chip), flow EP (0.1 ms/10 V pulses at 200 Hz), and EP (single 15 ms/15000 V pulse), highlighting that DFE produces earlier expression. Panel (d) quantifies expression timing: more than 80% of transfected cells expressed GFP within 1 h after microinjection and DFE, whereas most transfected cells in flow EP, EP, and Lipofectamine express between 4–48 h; cell counts for each method indicate relative throughput. Data points are triplicates with ± s.d.
- Fig. 3 visualizes labeled plasmid DNA delivery to HeLa cells using confocal imaging after nucleus and plasma membrane staining and mixing with Cy3-labeled DNA. Panel (a) shows that squeezing alone (10-7 chip at 500 mm/s) produced no detectable intracellular labeled DNA. Panel (b) shows conventional electroporation (NEON, 15 ms/1200 V) led to DNA accumulation at the plasma membrane as bright localized spots. Panel (c) shows DFE (10-7 chip at 500 mm/s with 0.1 ms pulses at 200 Hz and 10 V) produced substantial Cy3 fluorescence distributed in plasma membrane, cytoplasm, and nucleus. Panel (d) plots relative fluorescence intensity across single cells for the three treatments, demonstrating different DNA distributions: no intracellular signal for squeezing, membrane-localized peaks for EP, and nuclear plus cytoplasmic signal for DFE. Scale bar = 10 μm; original confocal images are provided.
- Fig. 4 examines ESCRT-III (CHMP4B-GFP) recruitment for plasma membrane and nuclear envelope repair after treatments. HeLa cells expressing CHMP4B-GFP were fixed at multiple time points (0.5–15 minutes) post treatment with squeezing, EP, or DFE and imaged. Panel (a) shows representative confocal images at 1.5 minutes: CHMP4B-GFP foci are visible at both plasma membrane and nuclear envelope after DFE but only at plasma membrane after squeezing and EP. Panels (b) and (c) quantify the number of CHMP4B-GFP foci at plasma membrane and nuclear envelope over time for S, EP, and DFE (mean of 10 cells per point ± s.d.), showing transient recruitment consistent with rapid ESCRT-mediated repair.
## Source note
The summary and sections were written from the public full text of the linked paper. They are not a word-for-word extract.
## Company note
This publication refers to SQZ Biotechnologies, a separate company previously founded by Dr. Armon Sharei. Dr. Sharei founded Portal Biotechnologies (Watertown, MA), which is develops the next generation of the platform technology mentioned in this publication.