A mechanical delivery platform enabling intracellular delivery of impermeable Polymers, peptides, and probes for enhanced drug discovery
- Cells
- iPSCs, T cells, Cancer Cell Lines, PBMCs
- Cargos
- mRNA, CRISPR RNPs, siRNA, Antibody, Oligo, Peptide, Protein, small molecules, Polymers
What this document says
This document is a poster describing Portal Biotechnologies’ mechanoporation platform for intracellular delivery. The poster presents a bench-top device and disposable MicroBooster™ cartridge that transiently deform cells at low pressures (3–15 PSI) to allow uptake of otherwise impermeable cargos. It shows schematic workflow diagrams, integration of the cartridge into an automated dispenser for high-throughput dispensing into pre-loaded multiwell plates, and experimental results across cell types and cargos (DEL probes, dextran, antibodies, oligos, macrocycles, mRNA, RNPs, and LgBiT protein) assessed by flow cytometry, microscopy, and luminescence assays. Figures compare control (unboosted) and boosted samples, demonstrate dose response and multiplex delivery, and illustrate consistent delivery across plates and preserved cell morphology after boosting.
Title block (top of page)
The poster title states the platform enables intracellular delivery of impermeable small molecules, peptides, and probes for enhanced drug discovery. Authors and Portal Biotechnologies affiliation are listed along with the company website.
Introduction to Portal’s Approach: Implementing a Universal Cell Engineering Solution
The introduction presents Portal’s vision of a broadly compatible cellular engineering technology that works across many cargos (small molecules, oligos, peptides, antibodies, DELs, mRNA, siRNA, DNA, RNPs, proteins) and primary or patient-derived cell types. It describes cells being ‘boosted’ through a membrane at low operating pressures (3–15 PSI) using a membrane format intended for high throughput, and mentions a compact bench-top unit and cell type–specific consumable cartridges (MicroBooster™) with defined pore sizes for deformation.
Background on Mechanoporation
This section summarizes prior work and the mechanoporation concept: mechanical deformation (squeezing) of cells through narrow channels transiently disrupts the membrane, allowing macromolecular cargos to enter the cytosol before the membrane reseals. It notes mechanoporation can deliver macromolecules to primary cells and cell lines, that cargo can be mixed with cells before resealing, and that mechanoporation has minimal impact on cell function and gene expression compared with electroporation and viral methods, with literature references listed.
Enabling High Throughput Screening by Automated Dispensing into Pre-loaded Cargo Plates
This section describes integrating a Portal cartridge in-line with the fluidics of an existing robotic dispenser so cells are porated as they transit the membrane and then deposited into wells pre-loaded with cargo. The workflow is presented as a single modification to a robot’s fluid path enabling automated dispensing of porated cells into multiwell plates for downstream analysis.
Robust DNA Encoded Library Delivery in iPSCs and HeLa Cells
The poster reports mechanoporation of iPSCs and HeLa cells with a fluorescently tagged DNA encoded library (DEL) probe. Delivery efficiency was assessed immediately post-boost by flow cytometry, comparing control and boosted samples, with boosted samples showing increased fluorescent signal indicative of probe delivery.
Consistent Delivery of Cargo Across Pre-loaded Plates by Automated Dispensing
This section presents data from automated dispensing of porated HeLa cells into pre-loaded 96-well plates (examples from Plate 2 and Plate 7). Flow cytometry readouts across wells demonstrate delivery signal present and consistent across plates, and phase contrast images show cell morphology at 10 minutes and 24 hours post-boost.
Efficient Co-delivery of Antibody, Oligos, and Dextran to HeLa Cells
Here, HeLa cells were mechanoporated with a mix of fluorescent IgG isotype control antibody, Cy5-labeled oligo, and fluorescent dextran. Post-boost flow cytometry compared viability and delivery across untreated versus boosted cells, showing increased fluorescence for each cargo in boosted samples while reporting viability for each condition.
Macrocycle Delivery to HeLa cells Shows Robust Dose Response
HeLa cells were boosted and added into wells pre-loaded with FITC-labeled macrocycle across a 0–96 µM concentration range. Flow cytometry measured macrocycle delivery and cell viability, and the figures show dose-dependent increases in fluorescence with increasing macrocycle concentration alongside viability data.
What the figures show
- Automated dispensing into multiwell plates: Photograph and schematic show a laboratory robotic single-head dispenser with a Portal consumable cartridge integrated in-line with the fluidics so cells pass through the cartridge membrane during dispensing. The process illustrated is cells being porated as they transit the membrane and then deposited into wells pre-loaded with cargo; example experiments described dispensed HeLa cells into 96-well plates containing fluorescent dextran and used flow cytometry and phase contrast imaging at 10 min and 24 h post-boost to assess delivery and cell morphology.
- Robust DNA Encoded Library Delivery in iPSCs and HeLa Cells: The figure contains schematic cell icons, flow cytometry histograms (Control vs Boost), and bar charts labeled for DEL delivery to iPSCs and HeLa. It compares unboosted controls to boosted samples and shows boosted samples with increased fluorescent signal, indicating intracellular delivery of a fluorescently tagged DEL probe measured immediately after boosting by flow cytometry.
- Consistent Delivery of Cargo Across Pre-loaded Plates by Automated Dispensing: Two plots display delivery readouts across well numbers for Plate 2 and Plate 7, comparing readouts at 10 minutes and 24 hours post-boost. Accompanying phase contrast micrographs show HeLa cell morphology at 10 min and 24 h. The panels illustrate that automated dispensing with the Portal cartridge produces delivery signals across wells and plates and that cells retain observable morphology over 24 hours.
- Efficient Co-delivery of Antibody, Oligos, and Dextran to HeLa Cells: This figure shows schematic icons for HeLa cells and three cargo types, flow cytometry histograms for each cargo (antibody, oligo, dextran), and bar charts for viability and delivery efficiency comparing untreated and boosted samples. The comparisons indicate increased fluorescence for each cargo in boosted cells and report viability percentages for the conditions, demonstrating simultaneous uptake of multiple cargo types after mechanoporation.
- Macrocycle Delivery to HeLa cells Shows Robust Dose Response: The figure includes a pipetting schematic and bar graphs/histograms showing viability and FITC-macrocycle delivery across concentrations from 0 to 96 µM. Representative flow cytometry histograms for each dose are shown, illustrating dose-dependent increases in fluorescence signal correlated with macrocycle concentration while reporting cell viability across doses.
- Efficient Delivery of Labeled Macrocycle to HEK293 Cells: Panels include bar plots for viability and macrocycle delivery and fluorescence plus transmitted-light micrographs of HEK293 cells comparing untreated and boosted samples. The boosted samples show higher FITC signal in flow cytometry and microscopy images, with viability data presented alongside to show cell health after mechanoporation.
- Robust Multiplex Delivery in Unstimulated T Cells: The figure presents bar graphs for GFP expression and B2M expression and flow cytometry contour plots comparing control and boosted naive T cells after multiplex delivery of GFP mRNA, fluorescent dextran, and B2M CRISPR RNPs. Boosted samples show GFP expression and altered B2M levels 40 hours post-delivery, demonstrating multiplexed functional readouts.
- Delivering Promega’s LgBiT Reagents for Intracellular Protein Detection: A schematic and a bar graph show luminescence measured after delivering LgBiT protein into HiBiT-tagged MiaPaCa-2 cells that had been treated with PROTAC LC-2 (0–10 µM). The luminescence bars decrease as PROTAC concentration increases, illustrating that LgBiT delivery combined with Nano-Glo detection reports on endogenous protein levels after degradation treatment.
The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.
# Publication
This page is a text version of a Portal Biotechnologies publication. The bibliographic record is labeled in the text so it can be read without the surrounding website.
## Bibliographic record
- Title: Publication
- Document type: Poster
- Year: 2024
- Outlet: Discovery on Target
- Cells: iPSCs, T cells, Cancer Cell Lines, PBMCs
- Cargos: mRNA, CRISPR RNPs, siRNA, Antibody, Oligo, Peptide, Protein, small molecules, Polymers
- Page URL: https://portal.bio/publications/2024-publication--ajkGUREAACgAc93u
- Markdown URL: https://portal.bio/publications/2024-publication--ajkGUREAACgAc93u.md
- Original file: https://portal-bio.cdn.prismic.io/portal-bio/aFot93fc4bHWipla_PortalDiscoveryonTargetPosterSept2024.pdf
## Portal description
A mechanical delivery platform enabling intracellular delivery of impermeable Polymers, peptides, and probes for enhanced drug discovery
## Summary
This document is a poster describing Portal Biotechnologies’ mechanoporation platform for intracellular delivery. The poster presents a bench-top device and disposable MicroBooster™ cartridge that transiently deform cells at low pressures (3–15 PSI) to allow uptake of otherwise impermeable cargos. It shows schematic workflow diagrams, integration of the cartridge into an automated dispenser for high-throughput dispensing into pre-loaded multiwell plates, and experimental results across cell types and cargos (DEL probes, dextran, antibodies, oligos, macrocycles, mRNA, RNPs, and LgBiT protein) assessed by flow cytometry, microscopy, and luminescence assays. Figures compare control (unboosted) and boosted samples, demonstrate dose response and multiplex delivery, and illustrate consistent delivery across plates and preserved cell morphology after boosting.
## Sections
### Title block (top of page)
The poster title states the platform enables intracellular delivery of impermeable small molecules, peptides, and probes for enhanced drug discovery. Authors and Portal Biotechnologies affiliation are listed along with the company website.
### Introduction to Portal’s Approach: Implementing a Universal Cell Engineering Solution
The introduction presents Portal’s vision of a broadly compatible cellular engineering technology that works across many cargos (small molecules, oligos, peptides, antibodies, DELs, mRNA, siRNA, DNA, RNPs, proteins) and primary or patient-derived cell types. It describes cells being ‘boosted’ through a membrane at low operating pressures (3–15 PSI) using a membrane format intended for high throughput, and mentions a compact bench-top unit and cell type–specific consumable cartridges (MicroBooster™) with defined pore sizes for deformation.
### Background on Mechanoporation
This section summarizes prior work and the mechanoporation concept: mechanical deformation (squeezing) of cells through narrow channels transiently disrupts the membrane, allowing macromolecular cargos to enter the cytosol before the membrane reseals. It notes mechanoporation can deliver macromolecules to primary cells and cell lines, that cargo can be mixed with cells before resealing, and that mechanoporation has minimal impact on cell function and gene expression compared with electroporation and viral methods, with literature references listed.
### Enabling High Throughput Screening by Automated Dispensing into Pre-loaded Cargo Plates
This section describes integrating a Portal cartridge in-line with the fluidics of an existing robotic dispenser so cells are porated as they transit the membrane and then deposited into wells pre-loaded with cargo. The workflow is presented as a single modification to a robot’s fluid path enabling automated dispensing of porated cells into multiwell plates for downstream analysis.
### Robust DNA Encoded Library Delivery in iPSCs and HeLa Cells
The poster reports mechanoporation of iPSCs and HeLa cells with a fluorescently tagged DNA encoded library (DEL) probe. Delivery efficiency was assessed immediately post-boost by flow cytometry, comparing control and boosted samples, with boosted samples showing increased fluorescent signal indicative of probe delivery.
### Consistent Delivery of Cargo Across Pre-loaded Plates by Automated Dispensing
This section presents data from automated dispensing of porated HeLa cells into pre-loaded 96-well plates (examples from Plate 2 and Plate 7). Flow cytometry readouts across wells demonstrate delivery signal present and consistent across plates, and phase contrast images show cell morphology at 10 minutes and 24 hours post-boost.
### Efficient Co-delivery of Antibody, Oligos, and Dextran to HeLa Cells
Here, HeLa cells were mechanoporated with a mix of fluorescent IgG isotype control antibody, Cy5-labeled oligo, and fluorescent dextran. Post-boost flow cytometry compared viability and delivery across untreated versus boosted cells, showing increased fluorescence for each cargo in boosted samples while reporting viability for each condition.
### Macrocycle Delivery to HeLa cells Shows Robust Dose Response
HeLa cells were boosted and added into wells pre-loaded with FITC-labeled macrocycle across a 0–96 µM concentration range. Flow cytometry measured macrocycle delivery and cell viability, and the figures show dose-dependent increases in fluorescence with increasing macrocycle concentration alongside viability data.
## What the figures show
- Automated dispensing into multiwell plates: Photograph and schematic show a laboratory robotic single-head dispenser with a Portal consumable cartridge integrated in-line with the fluidics so cells pass through the cartridge membrane during dispensing. The process illustrated is cells being porated as they transit the membrane and then deposited into wells pre-loaded with cargo; example experiments described dispensed HeLa cells into 96-well plates containing fluorescent dextran and used flow cytometry and phase contrast imaging at 10 min and 24 h post-boost to assess delivery and cell morphology.
- Robust DNA Encoded Library Delivery in iPSCs and HeLa Cells: The figure contains schematic cell icons, flow cytometry histograms (Control vs Boost), and bar charts labeled for DEL delivery to iPSCs and HeLa. It compares unboosted controls to boosted samples and shows boosted samples with increased fluorescent signal, indicating intracellular delivery of a fluorescently tagged DEL probe measured immediately after boosting by flow cytometry.
- Consistent Delivery of Cargo Across Pre-loaded Plates by Automated Dispensing: Two plots display delivery readouts across well numbers for Plate 2 and Plate 7, comparing readouts at 10 minutes and 24 hours post-boost. Accompanying phase contrast micrographs show HeLa cell morphology at 10 min and 24 h. The panels illustrate that automated dispensing with the Portal cartridge produces delivery signals across wells and plates and that cells retain observable morphology over 24 hours.
- Efficient Co-delivery of Antibody, Oligos, and Dextran to HeLa Cells: This figure shows schematic icons for HeLa cells and three cargo types, flow cytometry histograms for each cargo (antibody, oligo, dextran), and bar charts for viability and delivery efficiency comparing untreated and boosted samples. The comparisons indicate increased fluorescence for each cargo in boosted cells and report viability percentages for the conditions, demonstrating simultaneous uptake of multiple cargo types after mechanoporation.
- Macrocycle Delivery to HeLa cells Shows Robust Dose Response: The figure includes a pipetting schematic and bar graphs/histograms showing viability and FITC-macrocycle delivery across concentrations from 0 to 96 µM. Representative flow cytometry histograms for each dose are shown, illustrating dose-dependent increases in fluorescence signal correlated with macrocycle concentration while reporting cell viability across doses.
- Efficient Delivery of Labeled Macrocycle to HEK293 Cells: Panels include bar plots for viability and macrocycle delivery and fluorescence plus transmitted-light micrographs of HEK293 cells comparing untreated and boosted samples. The boosted samples show higher FITC signal in flow cytometry and microscopy images, with viability data presented alongside to show cell health after mechanoporation.
- Robust Multiplex Delivery in Unstimulated T Cells: The figure presents bar graphs for GFP expression and B2M expression and flow cytometry contour plots comparing control and boosted naive T cells after multiplex delivery of GFP mRNA, fluorescent dextran, and B2M CRISPR RNPs. Boosted samples show GFP expression and altered B2M levels 40 hours post-delivery, demonstrating multiplexed functional readouts.
- Delivering Promega’s LgBiT Reagents for Intracellular Protein Detection: A schematic and a bar graph show luminescence measured after delivering LgBiT protein into HiBiT-tagged MiaPaCa-2 cells that had been treated with PROTAC LC-2 (0–10 µM). The luminescence bars decrease as PROTAC concentration increases, illustrating that LgBiT delivery combined with Nano-Glo detection reports on endogenous protein levels after degradation treatment.
## Layout reading
Transcription and full visual description of the poster "Publication"
Note: I used only the publisher short description you provided to recognize the subject (mechanical delivery platform for intracellular delivery). I did not add any claims beyond the text and images on the page. I transcribe labeled sections in visual reading order and describe every chart/graph/diagram/photo/schematic in plain language as requested.
Title block (top of page)
- Title (large): "A mechanical delivery platform enabling intracellular delivery of impermeable small molecules, peptides, and probes for enhanced drug discovery"
- Authors: "Sophia Hirsch, Andrew Larocque, Eleni Rogers, Darby Kreienberg, Zhihui Song, Jacquelyn Hanson, Mathias Pawlak, Alec Barclay, Armon Sharei"
- Affiliation: "Portal Biotechnologies, 134 Coolidge Ave, Watertown, MA 02472, USA. www.portal.bio"
Section: "Introduction to Portal’s Approach: Implementing a Universal Cell Engineering Solution"
Subhead columns (left to right): "Cells and Cargo", "Mechanical Disruption via Boosting", "Intracellular Delivery", "Research-Scale System", "Consumable Delivery Cartridge", "High-Throughput Capabilities"
Text and bullets below these headings:
- Left column (Cells and Cargo)
- "● Portal is creating a transformative technology for cellular engineering compatible across cell types and cargos"
- "○ Small molecules, oligos, peptides, antibodies, DELs, mRNA, siRNA, DNA, RNPs, proteins, and other cargos"
- "○ Primary and patient-derived cell lines including immune and stem cells"
- "● Cells are boosted through a membrane at low operating pressure (3-15 PSI)"
- "○ Membrane format1 enables high-throughput cellular engineering"
- Footnote: "1. Williams AR, Bao S, Miller DL. Biotechnol Bioeng. 1999"
- Middle column (Mechanical Disruption via Boosting, Intracellular Delivery)
- Small icons/graphics depict cells and cargo passing through a membrane or narrow aperture; there are schematic cell icons before and after a membrane labeled "Cells" and "Cargo".
- "Cells are boosted through a membrane at low operating pressure (3-15 PSI)" (repeated from left column)
- "Compact bench-top unit that controls delivery parameters and easily fits in hood" (under Research-Scale System heading)
- Under Consumable Delivery Cartridge (MicroBooster™):
- "18mm" and "35mm" labels appear near a cartridge illustration
- "Cell type-specific consumable for optimal mechanoporation-mediated cargo delivery"
- "Defined pore size for deformation"
- Under High-Throughput Capabilities ("'Powered by Portal' Consumables"):
- "● Low pressure requirements enable integration into existing robotics"
- "● Ready for early adopters 2024"
Section: "Background on Mechanoporation"
- Bulleted text:
- "● Previous work has shown that mechanical deformation of cells through a microfluidic channel enables cytosolic intracellular delivery1"
- "○ Delivers macromolecules2,3,4 to both primary cells and cell lines"
- "● Cells are squeezed through a narrow channel at high pressure. The cell membrane is temporarily disrupted, allowing the target cargo to enter the cytosol before the membrane seals5."
- "○ Cells can be mixed with cargo or added before membrane re-sealing"
- "● Mechanoporation has minimal impact on cell function and gene expression, in contrast to electroporation and viral delivery methods6"
- References listed:
1. Sharei, et al., PNAS, 2013
2. Szeto, et al., Scientific Reports, 2015
3. Sharei, et al., PLOS One, 2015
4. Lee and Sharei, et al. Nano Letters 2012
5. Sharei et al., Integrative Biology 2014
6. DiTommaso, et al., PNAS, 2018
Section: "Enabling High Throughput Screening by Automated Dispensing into Pre-loaded Cargo Plates"
- Left column text:
- "Automated dispensing into multiwell plates"
- "● Portal cartridge integrated in-line with the fluidics of an existing robot. The highlighted component is the only addition/modification"
- "● Cells are porated as they transit through the membrane"
- "● Cargo is pre-plated in the wells and the porated cells take up material upon entering the well"
- Right side image: photograph (robotic dispenser and cartridge)
- Caption text (below figure): "A cartridge was designed for integration of mechanoporation with a robotic single-head dispenser. HeLa cells were automatically dispensed into 96-well plates pre-loaded with fluorescent dextran. Flow cytometry was used to assess dextran delivery. Data for delivery across the 2nd (wells 97-192) and 7th (wells 577-672) 96-well plates are shown here. Phase contrast images (right) show morphology of HeLa cells 10 minutes (top) and 24 hours (bottom) post-boost. Scale bar (white) = 300 μm."
Figure: "Automated dispensing into multiwell plates" (image and small schematic of cartridge in robot)
- Plain-language description: The image shows a laboratory robot dispenser head with a Portal consumable cartridge inserted in-line with the fluid path. The schematic/component highlight indicates where the Portal cartridge integrates so that cells pass through the cartridge membrane when dispensed into wells. The process illustrated: porate cells as they pass through the membrane, then cells are potentially deposited into wells that already contain cargo; cells take up cargo upon entry. The result shown by the accompanying experimental note: HeLa cells were dispensed into 96-well plates pre-loaded with fluorescent dextran and later analyzed by flow cytometry and phase contrast imaging to assess delivery and cell morphology at 10 min and 24 h after boosting.
Section: "Robust DNA Encoded Library Delivery in iPSCs and HeLa Cells"
Top row: small icons representing iPSCs and HeLa cells with heading "iPSC Boost" and "HeLa Boost"
Left area: two small schematic flow cytometry histograms and two bar plots labeled "iPSC Boost" and "iPSC Boost" and "DEL delivery to iPSCs" (bar chart) and "DEL delivery to HeLa" (bar chart).
Text under figure:
- "Induced pluripotent stem cells (iPSCs) or HeLa cells were mechanoporated with a fluorescently-tagged DNA encoded library (DEL) probe. Delivery efficiency was measured using flow cytometry to detect the fluorescent tag immediately after boosting."
- There are side-by-side small flow cytometry histogram images labeled "Control" and "Boost" and bars showing counts for fluorescent-tagged DEL probe.
Plain-language description of this figure:
- What is drawn: The figure includes small schematic icons for cell types, bar graphs labelled "DEL delivery to iPSCs" and "DEL delivery to HeLa", and overlaid flow cytometry histograms comparing "Control" and "Boost".
- What is compared: Delivery (fluorescent signal) in control (unboosted) vs. boosted cells for iPSCs and HeLa.
- What the result shows: The boosted samples show higher fluorescence indicative of probe delivery compared to controls (as depicted by taller bar heights and histograms shifted to the right).
- How the process works: Cells are mechanoporated (boosted) while exposed to a fluorescent DEL probe; flow cytometry immediately after boosting measures intracellular fluorescence to report delivery efficiency.
Section: "Consistent Delivery of Cargo Across Pre-loaded Plates by Automated Dispensing"
This area includes:
- Title: "Consistent Delivery of Cargo Across Pre-loaded Plates by Automated Dispensing"
- Subheading: "HeLa cells" and "Dextran Delivery to HeLa Cells by Automated Dispensing"
- Two small plots labeled "Well # (Plate 2)" and "Well # (Plate 7)" with x-axis labeled well numbers and y-axis presumably percent fluorescence (scale not explicitly readable in the text). Two time points are mentioned: "10 min post-boost" and "24h post-boost".
- Side-by-side phase contrast micrographs (right) showing HeLa cells at 10 min post-boost (top) and 24 h post-boost (bottom); scale bar = 300 μm.
Plain-language description:
- What is drawn: Two scatter/line plots show delivery readouts for wells across an entire 96-well plate at two different plate positions (Plate 2 and Plate 7). Two phase contrast microscope images show HeLa cell morphology 10 minutes and 24 hours after boosting.
- What is compared: Delivery signal across wells in different plates (Plate 2 vs Plate 7) and at two time points (10 min and 24 h).
- What the result shows: The plotted data indicate delivery across wells is present and consistent across the plates sampled; phase contrast images show cells with morphology at the two time points (no additional text claims were added).
- How the process works: A Portal cartridge integrated into a dispenser automates dispensing of porated cells into wells pre-loaded with fluorescent dextran; flow cytometry assesses dextran uptake across wells and across multiple plates.
Section: "Efficient Co-delivery of Antibody, Oligos, and Dextran to HeLa Cells"
Top left header: "Efficient Co-delivery of Antibody, Oligos, and Dextran to HeLa Cells"
Graphic content:
- Leftmost: schematic icons representing HeLa cells and three cargo types: "Antibody", "Oligo", "Dextran". Large flow cytometry plots and bar charts are included.
- Text below schematic:
- "Fluorescently-labeled IgG isotype control antibody, Cy5-labeled oligo, and fluorescent dextran were mixed and mechanoporated into HeLa cells. Flow cytometry was conducted post-boost to assess viability and delivery of the cargo types to the cells."
- The figure elements include:
- A viability bar graph (y-axis viability %) with bars for "Untreated", "Boost" (and possibly "Boost with no cargo" in other panels).
- Delivery efficiency bar graphs labeled for each cargo type (Antibody, Oligo, Dextran) comparing Untreated and Boosted.
- Flow cytometry histogram panels (three histograms) showing shifts in fluorescence for each cargo comparing control and boosted samples.
Plain-language description:
- What is drawn: Bar charts and flow cytometry histograms compare viability and delivery efficiency of three fluorescent cargoes (antibody, labeled oligo, dextran) delivered simultaneously into HeLa cells by mechanoporation.
- What is compared: Untreated (control) vs boosted cells for viability and uptake of each cargo type.
- What the result shows: The boosted cells show increased fluorescence signals for the antibody, oligo, and dextran relative to control, implying co-delivery of multiple cargoes; viability chart shows the fraction of viable cells for each condition.
- How the process works: Cells are mixed with multiple fluorescent cargoes and passed through the mechanoporation membrane (boosted), then analyzed by flow cytometry to measure uptake and viability.
Section: "Macrocycle Delivery to HeLa cells Shows Robust Dose Response"
Layout and content:
- Schematic: a pipetting diagram showing cells being added into wells pre-loaded with labeled macrocycle at concentrations 0 - 96 µM.
- Small bar charts: "Viability of HeLa cells" and "Delivery of macrocycle to HeLa cells" across dose conditions. Flow cytometry histograms show increasing fluorescence with increasing macrocycle concentration (0 µM, 12 µM, 24 µM, 48 µM, 96 µM).
- Caption text: "HeLa cells were boosted then manually added into wells of a 96-well plate pre-loaded with FITC-labeled macrocycle at 0 - 96 µM. Flow cytometry was conducted post-boost to assess viability and efficiency of macrocycle delivery into boosted cells."
Plain-language description:
- What is drawn: A pipetting schematic and bar graphs/histograms showing cell viability and macrocycle delivery across a dose range (0 to 96 µM). Representative flow cytometry histograms show fluorescence at each macrocycle concentration.
- What is compared: Different macrocycle concentrations and their effect on delivery signal and cell viability.
- What the result shows: The histograms and delivery panels show dose-dependent increases in fluorescence consistent with higher macrocycle concentration producing greater delivery signal; viability plots indicate cell viability across the tested concentrations.
- How the process works: Cells are boosted (mechanoporated) and then placed into wells containing different concentrations of FITC-labeled macrocycle so that the boosted cells encounter the cargo and uptake is measured after exposure.
Section: "Efficient Delivery of Labeled Macrocycle to HEK293 Cells"
Content and images:
- Heading: "Efficient Delivery of Labeled Macrocycle to HEK293 Cells"
- Left: small schematic with "HEK293 cells" and FITC labeled macrocycle icon; bar graphs for "Viability of HEK293 cells" and "Macrocycle delivery to HEK293".
- Right: two microscopy images labeled "FITC" and "Transmitted light" showing untreated and boosted samples (or control vs boost) with scale bar = 300 μm.
- Text: "HEK293 cells were mechanoporated with a FITC-labeled macrocycle. Flow cytometry was used to assess viability and macrocycle delivery to the untreated and boosted samples. Delivery was also assessed by fluorescence microscopy (right). Scale bar = 300 μm."
Plain-language description:
- What is drawn: Bar plots of viability and delivery efficiency, plus fluorescence and transmitted-light micrographs of HEK293 cells, comparing untreated and boosted conditions after exposure to FITC-labeled macrocycle.
- What is compared: Untreated vs. boosted HEK293 cells for macrocycle uptake and viability.
- What the result shows: The boosted sample shows a higher FITC signal (in flow cytometry bars and in FITC micrograph) compared to untreated; micrographs visually compare fluorescence localization. Viability bars show cell survival after treatment.
- How the process works: HEK293 cells are mechanoporated in the presence of a FITC-labeled macrocycle and then analyzed by flow cytometry and microscopy to evaluate intracellular delivery and cell health.
Section: "Robust Multiplex Delivery in Unstimulated T Cells"
Content:
- Heading: "Robust Multiplex Delivery in Unstimulated T Cells"
- Schematic icon: "Naive T cells" isolated from PBMCs.
- Text: "Naive T cells were isolated from PBMCs and mechanoporated with a multiplexed cargo containing GFP mRNA, fluorescently-labeled dextran polymers, and β2 microglobulin (B2M) CRISPR RNPs. After 40h, expression of mRNA and B2M protein were assessed by flow cytometry."
- Figures:
- Bar graph labeled "GFP expression" showing a bar for "Control" and a taller bar for "Boost".
- Bar graph labeled "B2M expression" showing reduced B2M expression in boosted samples compared to control (implying B2M editing).
- Flow cytometry scatter/contour plot on the right showing populations for Control and Boost with axes likely GFP signal vs some other marker (labels shown: "Control" and "Boost" and boxed gating regions).
Plain-language description:
- What is drawn: Bar graphs showing GFP expression and B2M expression in naive T cells, and flow cytometry plots comparing control and boosted samples after multiplex delivery of GFP mRNA, fluorescent dextran, and B2M RNPs.
- What is compared: Control (unboosted) vs boosted T cells for GFP expression (mRNA delivery) and B2M expression (protein level after CRISPR RNP).
- What the result shows: Boosted cells show GFP expression (bar higher than control) and a change in B2M expression compared with control, showing multiplexed outcomes measured 40 h post-delivery.
- How the process works: Naive T cells are mechanoporated in the presence of multiple cargos (mRNA, dextran, RNP); after incubation, flow cytometry quantifies protein expression and target knockdown or editing outcomes.
Section: "Delivering Promega’s LgBiT Reagents for Intracellular Protein Detection"
Left side text and small schematic:
- "Endogenous protein with HiBiT"
- Bulleted text:
- "● MiaPaCa-2 cells endogenously tagged with HiBiT at the KRAS(G12C) locus were treated with the PROTAC LC-2 for 24 hours (0-10 μM) and mechanoporated with LgBiT protein (Promega)"
- "● Nano-Glo® Endurazine™ was added and luminescence was detected on a GloMAX plate reader to detect degradation of KRAS(G12C)"
- "● Potential utility in other intracellular labeling assays to determine PPIs, degradation and other live cell kinetics"
Center graph (bar graph)
- Title above graph: "LgBiT delivery for luminescence (24h PROTAC treatment)"
- A bar graph with x-axis showing LC-2 concentration (0 - 10 μM) and y-axis luminescence (relative units). Bars decrease in height as LC-2 concentration increases (indicating decreased luminescence with higher PROTAC).
- Text annotation near graph: "Degradation removes signal"
Plain-language description of this figure:
- What is drawn: A bar graph showing luminescence measured after mechanoporation delivery of LgBiT protein into cells that were treated with varying concentrations (0 - 10 μM) of PROTAC LC-2 for 24 hours.
- What is compared: Luminescence signal across different LC-2 concentrations.
- What the result shows: The luminescence signal decreases with increasing LC-2 concentration, consistent with the caption text "Degradation removes signal."
- How the process works: Cells with endogenous HiBiT-tagged protein were treated with a PROTAC (LC-2) to induce degradation; LgBiT protein is delivered intracellularly by mechanoporation; Nano-Glo reagent is added and luminescence read on a plate reader to quantify the amount of HiBiT-tagged protein remaining.
Section: "Summary" (right-center bottom)
Bulleted summary points:
- "● Portal’s mechanoporation technology can be used for drug discovery and cell engineering"
- "● Efficient delivery of diverse impermeable molecules for use in downstream screening including:"
- a row of icons and labels: "DELs", "Peptides", "Macrocycle", "Antibodies", "Small molecules"
- "● Compatible across broad cell types including:"
- list/column of cell types: "PBMCs", "T cells", "B cells", "HeLa cells", "NK cells", "HSCs", "iPSCs", "HEK293 cells", "+ Other cell lines"
- "● Simple workflow enabling high throughput capabilities"
- "● Can be used to deliver single or multiplexed cargoes"
- "● Little impact on normal cellular function or morphology"
- Website: "www.portal.bio"
Bottom-right: "Connect with Portal!" boxed contact callout
- Text: "Contact us for beta program eligibility"
- A QR code graphic and button-like text "LET'S BOOST TOGETHER!"
- Portal logo and website repeated: "www.portal.bio"
All images, schematics, graphs and photos on the poster — overall plain-language summary of the visuals and how the process works
- What is drawn across the poster: The poster contains schematics of a bench-top research unit and a disposable cartridge (MicroBooster™) through which cells are forced (boosted) to transiently disrupt the cell membrane. There are photographs of an automated dispenser with the Portal cartridge integrated, fluorescence and transmitted-light microscopy images, multiple bar graphs and flow cytometry histograms showing delivery efficiency and viability for various cargos (DEL probe, dextran, antibody, labeled oligo, FITC-labeled macrocycle), dose-response data for FITC-macrocycle, multiplex delivery data in primary T cells (GFP mRNA, dextran, B2M RNP), and a luminescence assay demonstrating LgBiT delivery to HiBiT-tagged cells after PROTAC treatment.
- What is compared: Most figures compare control/unboosted cells versus boosted cells, different cargo types delivered simultaneously, delivery across multiple wells/plates and automation consistency, dose response of a macrocycle (0 - 96 µM), and luminescence across PROTAC concentrations (0 - 10 µM).
- What the results show (as presented on the poster): Boosted cells generally show increased intracellular signal from fluorescent or luminescent reporters versus control/unboosted, demonstrating delivery of impermeable cargos. The automation figure shows delivery across multiple 96-well plates and preserved cell morphology by microscopy at 10 min and 24 h. Multiplexed delivery to naive T cells produced measurable GFP expression and changes in B2M expression 40 h post-delivery. LgBiT luminescence decreased with increasing PROTAC concentration after LgBiT delivery into HiBiT-tagged cells, consistent with target degradation removing the luminescence signal.
- How the depicted process works (overall): Cells are flowed or dispensed through a Portal consumable cartridge membrane at low operating pressures (3-15 PSI) that mechanically deform cells (mechanoporation or "boosting"). This transient membrane disruption allows extracellular cargos—such as fluorescently labeled probes, DELs, nucleic acids, proteins (LgBiT), oligos, dextran polymers, antibodies, macrocycles, and RNPs—to enter the cytosol. After passage through the membrane, the cell membrane reseals and cells are analyzed by flow cytometry, microscopy, or luminescence assays. The consumable cartridge is designed to be integrated with robotic dispensers for automated, high-throughput workflows (e.g., dispensing porated cells into wells pre-loaded with cargo).
If you would like, I can:
- Read aloud any specific graph or flow cytometry histogram in more detail (report axes, approximate values seen, and numeric bar heights as printed).
- Extract the legend or exact axis tick labels from any particular subfigure if you want precise numeric transcription.
## Source note
The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.