Poster · 2025 · SLAS (Europe)

Enabling novel live cell assays with a silicon membrane-based platform for mechanical delivery of impermeable small molecules, peptides, and probes to accelerate early drug discovery

Anil Narasimha, Sophia Hirsch, Darby Kreienberg, Andrew Larocque, Eleni Rogers, Zhihui Song, Xi Ai, James Vasta, Matthew Robers, Alec Barclay, Armon Sharei

Cells
T cells, iPSCs, PBMCs, Cancer Cell Lines
Cargos
mRNA, CRISPR RNPs, circRNA, small molecules, Polymers

What this document says

This document presents Portal Biotechnologies' silicon membrane-based mechanoporation platform and instruments (Gateway™, MicroBooster™ cartridge, and Galaxy™) for mechanically delivering membrane‑impermeable cargos into live cells. It provides examples across cell types (HeLa, HEK293, iPSCs, PBMCs, activated and unstimulated T cells, MiaPaCa-2) showing delivery of small molecules, fluorescent probes, DNA-encoded library (DEL) probes, macrocycles, mRNA, circRNA, proteins (LgBiT), and CRISPR RNPs. Assays demonstrate improved delivery versus electroporation for a JAK‑STAT inhibitor, reproducible dispensing into pre-loaded multiwell plates including inline robotic workflows, dose responses for macrocycle uptake, intracellular target engagement and BRET assays with impermeable tracers, intracellular protein detection via LgBiT complementation, and functional engineering of T cells (CD19 CAR and mbIL-12) and multiplexed delivery in unstimulated T cells. The poster emphasizes compatibility with research and high-throughput workflows and highlights preserved cell viability and assay readouts following mechanoporation.

Introduction to Portal’s Approach: Implementing a Universal Cell Engineering Solution

Portal describes a silicon membrane-based mechanoporation workflow intended to be compatible across many cell types and cargo classes (small molecules, oligos, peptides, antibodies, DELs, mRNA, siRNA, DNA, RNPs, proteins). Cells are boosted through a membrane at low operating pressure (3–15 PSI) using a bench-top Gateway™ unit or high-throughput Galaxy™ system and MicroBooster™ consumable cartridges with defined pore sizes. The systems are shown as compatible with liquid handlers and in-line robotics to enable research- and screening-scale delivery.

Background on Mechanoporation

The poster summarizes prior mechanoporation concepts where mechanical deformation through narrow channels transiently disrupts the cell membrane, permitting cytosolic delivery of macromolecules to primary cells and cell lines before membrane resealing. References to earlier literature are provided to contextualize mechanical delivery as an established approach for intracellular access.

Mechanoporation Can be Used to Deliver Membrane Impermeable Cargo to Cells

An experiment delivered a cell‑impermeable JAK‑STAT inhibitor (identified in a cell‑free screen) into mixed PBMCs by either electroporation or mechanoporation. Flow cytometry assessed viability and compound delivery, and activity was confirmed by STAT knockdown. The mechanoporation condition showed improved delivery relative to electroporation and resulted in STAT knockdown, supporting intracellular activity of the delivered inhibitor.

Enabling High Throughput Screening by Dispensing into Pre-loaded Multiwell Cargo Plates

FITC‑labeled oligo and Cascade blue‑labeled 3 kDa dextran were dispensed into 96‑well plates. HeLa cells were mechanoporated in a trough on the Galaxy system and then dispensed across five 96‑well plates with a multichannel. Flow cytometry from plates 1 and 5 shows consistent delivery across plate columns, indicating reproducible delivery across multiple plates in this workflow.

Robust DNA Encoded Library Delivery in iPSCs and HeLa Cells

iPSCs and HeLa cells were mechanoporated with a fluorescently tagged DNA encoded library (DEL) probe and analyzed immediately by flow cytometry. Boosted (mechanoporated) conditions in both cell types show increased fluorescent signal versus controls, indicating effective DEL probe delivery by mechanoporation.

Consistent Delivery of Cargo Across Pre-loaded Plates by Automated In line dispensing

A cartridge designed for in-line integration with a robotic single‑head dispenser enabled automated dispensing of mechanoporated HeLa cells into sequential pre-loaded 96‑well plates. Flow cytometry for fluorescent dextran delivery across Plate 2 and Plate 7 demonstrates consistent delivery across wells and later plates in the run. Phase contrast images at 10 minutes and 24 hours post‑boost show cell morphology, supporting cell health after boosting.

Macrocycle Delivery to HeLa cells Shows Robust Dose Response

HeLa cells were mechanoporated and dispensed into wells pre-loaded with FITC‑labeled macrocycle across a concentration range (0–0.2 mg/mL / 0–96 µM). Flow cytometry demonstrates a dose‑dependent increase in macrocycle uptake in boosted cells while untreated cells show little to no fluorescence; viability metrics indicate boosted cells remain viable across doses.

Efficient Delivery of Labeled Macrocycle to HEK293 Cells

HEK293 cells mechanoporated with a FITC‑labeled macrocycle were assessed by flow cytometry and fluorescence microscopy. Boosted cells show strong FITC signal and maintained viability compared to untreated cells, and microscopy confirms intracellular localization of the labeled macrocycle in boosted samples.

What the figures show

  • Efficient JAK Compound Delivery / Corresponding STAT Knockdown: Two schematic plots compare electroporation (orange) and mechanoporation (blue) for delivering a cell‑impermeable JAK‑STAT inhibitor into mixed PBMCs. The left overlay indicates improved delivery with mechanoporation versus electroporation as measured by flow cytometry, and the right plot shows STAT knockdown across conditions. The figure demonstrates that mechanoporation enabled greater intracellular delivery of the inhibitor and that the delivered compound produced STAT knockdown, supporting intracellular activity after boosting.
  • Plate delivery to HeLa cells: A line chart plots percent delivery to HeLa cells across 96‑well plate columns for Plate 1 and Plate 5 after mechanoporation in a trough and dispensing into pre‑loaded wells containing fluorescent cargos (FITC oligo and Cascade blue dextran). The plotted series for both plates are consistent across columns, indicating reproducible delivery across wells and plates. This illustrates the Galaxy system's ability to mechanoporate cells and dispense them into multiple pre‑loaded plates for high‑throughput screening.
  • DNA Encoded Library Delivery in iPSCs and HeLa Cells: Two panels labeled 'iPSC Boost' and 'HeLa Boost' show fluorescence distributions or percent positive cells comparing control versus boosted conditions. Boosted samples in both cell types have increased fluorescence relative to controls, indicating immediate uptake of a fluorescent DEL probe via mechanoporation and demonstrating delivery in both stem cells and a cancer cell line.
  • In-line automated dispensing workflow schematic: A small schematic depicts a mechanoporation cartridge integrated with a robotic dispenser that sequentially dispenses boosted cells into pre‑loaded 96‑well plates. This diagram demonstrates how mechanoporation can be coupled to automation for high‑throughput workflows, enabling boosted cells to be delivered into many plates with robotic handling.
  • Dextran Delivery to HeLa Cells by Automated Dispensing: Line plots show percent dextran delivery across wells for Plate 2 and Plate 7 at 10 minutes and 24 hours post‑boost. Delivery percentages remain consistent across wells and between early and later plates in the run, indicating stable performance during an automated sequence. Accompanying phase contrast images at 10 min and 24 h (scale bar = 300 μm) show cell morphology, supporting maintained cell health after boosting.
  • Macrocycle Dose Response in HeLa Cells: Bar charts and flow cytometry histograms display FITC‑macrocycle uptake across increasing concentrations (0–96 μM) and compare boosted versus untreated cells. Boosted cells show a dose‑dependent increase in fluorescence while untreated cells show little uptake; viability bars indicate boosted cells remain viable across doses. This demonstrates mechanoporation enables quantitative, dose‑responsive intracellular delivery of macrocycles.
  • Macrocycle Delivery to HEK293 Cells (flow and microscopy): A bar graph compares percent macrocycle‑positive cells and viability for untreated vs boosted HEK293 cells, and paired fluorescence microscopy images (transmitted light and FITC) show intracellular green fluorescence in boosted cells. Boosted samples exhibit strong intracellular FITC signal and preserved viability, visually confirming delivery and cell health.
  • Intracellular LgBiT Detection of KRAS(G12C) Degradation: A schematic and bar graph illustrate MiaPaCa‑2 cells with endogenous HiBiT‑tagged KRAS(G12C) mechanoporated with LgBiT and treated with PROTAC LC‑2 (0–10 μM). Luminescence measured after Nano‑Glo Endurazine addition decreases with higher LC‑2 concentrations, consistent with target degradation reducing HiBiT/LgBiT complementation signal. This shows mechanoporation can deliver protein reagents for intracellular complementation assays detecting degradation kinetics.
  • BRET Assays with Impermeable Kinase Tracer (concentration response): A dose‑response curve shows BRET signal increasing with tracer concentration in HeLa cells expressing SRC‑NanoLuc after mechanoporation of the impermeable tracer, with an inset schematic of NanoLuc‑SRC and tracer producing BRET. The curve indicates intracellular tracer binding to SRC yields measurable BRET and demonstrates tracer concentration dependence.
  • BRET Competition with Kinase Inhibitors: Bar plots/curves compare BRET signals when cells are pre‑incubated with Ponatinib or Bosutinib versus control, showing reduced BRET in inhibitor‑treated samples. This indicates inhibitors compete with the impermeable tracer for SRC binding inside cells, demonstrating the assay's ability to measure intracellular target engagement and competition.
  • Mechanoporated vs Digitonin mRNA BRET Profiles: Two grouped bar charts compare BRET profiles following NanoLuc mRNA delivery by mechanoporation versus digitonin permeabilization. The profiles are similar between the two methods, suggesting mechanoporation yields comparable assay readouts for mRNA delivery relative to chemical permeabilization.
  • Engineered Activated T cells: Flow cytometry plots show expression of CD19 CAR and membrane‑bound IL‑12 in activated T cells 48 hours after mechanoporation with corresponding circRNAs. A cytotoxicity plot displays killing of Raji target cells at varying effector:target ratios, with engineered T cells showing increased cytotoxicity. These figures demonstrate simultaneous delivery of multiple circRNA constructs and functional CAR activity post‑boost.

The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.