Poster · 2025 · Drug Discovery Chemistry

Enabling novel live cell assays with a silicon membrane-based platform for mechanical delivery of impermeable small molecules, peptides, and probes to accelerate early drug discovery

Crystal Tsui, Sophia Hirsch, Darby Kreienberg, Andrew Larocque, Eleni Rogers, Zhihui Song, Xi Ai, James Vasta, Matthew Robers, Alec Barclay, Armon Sharei

Cells
T cells, iPSCs, PBMCs, Cancer Cell Lines
Cargos
mRNA, CRISPR RNPs, Antibody, Oligo, Peptide, Protein, small molecules, Polymers, circRNA

What this document says

This document describes Portal Biotechnologies’ silicon membrane-based mechanoporation platform and workflows to deliver membrane-impermeable small molecules, peptides, nucleic acids, proteins, and probes into a range of cell types for live-cell assays and early drug discovery. The poster presents a modular hardware ecosystem (Gateway™, MicroBooster™ consumables, Galaxy™) and automated in-line integrations for high-throughput dispensing into pre-loaded multiwell plates. Representative applications and data shown include delivery and functional readouts for a cell-impermeable JAK inhibitor in PBMCs, delivery of fluorescent dextran, DEL probes, macrocycles, labeled macrocycles in HEK293, intracellular protein detection with LgBiT/HiBiT, intracellular target engagement BRET assays, mechanoporated mRNA giving comparable BRET profiles to digitonin permeabilization, and multiplexed engineering of T cells with circRNA and RNPs.

Introduction to Portal’s Approach: Implementing a Universal Cell Engineering Solution

Portal’s platform uses mechanoporation in which cells are boosted through a defined-pore membrane at low operating pressures (3–15 PSI) to transiently deform and disrupt the membrane to enable cytosolic delivery. The system is presented as modular: a research-scale Gateway™ instrument, cell type-specific MicroBooster™ consumables with defined pore sizes (18 mm noted), and a higher-throughput Galaxy™ system compatible with in-line integrations for robotics. The platform is described as compatible with diverse cargos (small molecules, oligos, peptides, antibodies, DELs, mRNA, siRNA, DNA, RNPs, proteins) and primary or patient-derived cell types.

Background on Mechanoporation

The poster summarizes prior work showing mechanical deformation through microchannels enables intracellular delivery of macromolecules to primary cells and cell lines. The described mechanism is that cells are squeezed through narrow channels, temporarily disrupting the membrane to allow cargo entry before membrane resealing. Several literature references are listed in support of the mechanoporation concept.

Mechanoporation Can be Used to Deliver Membrane Impermeable Cargo to Cells

A cell-impermeable JAK-STAT pathway inhibitor identified in a cell-free screen was delivered into mixed PBMCs by either electroporation or mechanoporation. Flow cytometry assessed viability and delivery, and downstream activity was confirmed by measuring STAT knockdown, with the poster indicating improved delivery using mechanoporation versus electroporation.

Enabling High Throughput Screening by Dispensing into Pre-loaded Multiwell Cargo Plates

The Galaxy system workflow mechanoporates cells into a trough and then dispenses them into multiple pre-loaded 96-well plates using multichannel or robotic dispensers. Examples shown include FITC-labeled oligo and cascade blue 3 kDa dextran dispensed into five 96-well plates with flow cytometry data displayed for Plate 1 and Plate 5, and delivery of a fluorescently-tagged DNA encoded library (DEL) probe to iPSCs and HeLa measured immediately after boosting.

Consistent Delivery of Cargo Across Pre-loaded Plates by Automated In line dispensing

A consumable cartridge was designed for in-line integration with a robotic single-head dispenser to automate dispensing of boosted cells into pre-loaded plates. Data examples include dextran delivery across Plate 2 (wells 97–192) and Plate 7 (wells 577–672) assessed by flow cytometry, plus phase-contrast images showing HeLa morphology at 10 minutes and 24 hours post-boost.

Macrocycle Delivery to HeLa and HEK293 Cells

HeLa cells were boosted with no cargo then pipetted into wells pre-loaded with FITC-labeled macrocycle at multiple concentrations (0, 12, 24, 48, 96 µM) and flow cytometry was used post-boost to assess viability and delivery showing a dose response. Separately, HEK293 cells mechanoporated with a FITC-labeled macrocycle were analyzed by flow cytometry and fluorescence microscopy to compare untreated and boosted samples.

Intracellular Protein Detection with Promega’s LgBiT Reagents

MiaPaCa-2 cells endogenously tagged with HiBiT at the KRAS(G12C) locus were treated with the PROTAC LC-2 (0–10 µM) for 24 hours, mechanoporated with LgBiT protein, and assayed with Nano-Glo Endurazine substrate on a plate reader. The poster shows luminescence decreasing with increasing LC-2 concentration, consistent with detection of target degradation using mechanoporated LgBiT.

Intracellular Target Engagement Assays with Impermeable Molecules

HeLa cells transfected with an SRC-NanoLuc fusion were mechanoporated with varying amounts of an impermeable kinase tracer and BRET was detected after adding NanoGlo substrate. In a separate assay, HeLa cells were incubated with Src inhibitors (Ponatinib or Bosutinib), mechanoporated with an impermeable tracer, and BRET measured to assess target engagement, with plotted BRET responses shown for tracer and inhibitor concentration series.

What the figures show

  • Top-row schematic sequence: A three-panel schematic showing cargo near a cell, the cell being forced through a membrane pore, and cargo inside the cell. The illustration depicts the steps of loading cargo, mechanical disruption via boosting through a defined pore membrane, and intracellular delivery, with a note that cells are boosted at low operating pressure (3–15 PSI) and that consumables have defined pore sizes to deform cells and enable transient membrane disruption.
  • Research-scale system and consumables illustrations: Rendered images of the Gateway™ bench-top unit, a MicroBooster™ delivery cartridge labeled with dimensions (18 mm) and defined pore size, and a Galaxy™ higher-throughput system. The visuals contrast the instrument, a cell type–specific consumable for optimal mechanoporation, and a system designed for scaling and integration with liquid handlers and robotics.
  • Background on mechanoporation: Text and reference panel summarizing prior literature with cited works; it shows the conceptual mechanism that mechanical deformation through microchannels delivers macromolecules to cells and that membranes reseal after temporary disruption. No raw data is shown—this is a conceptual background diagram with literature citations.
  • Efficient JAK compound delivery and corresponding STAT knockdown: A schematic labeled 'Mixed PBMCs' with an arrow indicating improved delivery using mechanoporation, alongside plots comparing electroporation (orange) and mechanoporation (blue). The figure shows flow cytometry-based delivery and a plot of STAT knockdown, indicating that a cell-impermeable JAK-STAT inhibitor identified in a cell-free screen was delivered and its activity confirmed by STAT knockdown.
  • High-throughput dispensing into pre-loaded multiwell plates (instrument photo and dextran delivery chart): A photo of the instrument/consumable and a line chart labeled 'Dextran delivery to HeLa cells' showing percent-positive traces across plate columns for Plate 1 and Plate 5. The figure illustrates the workflow where the Galaxy system mechanoporates cells into a trough and then dispenses them into multiple pre-loaded 96-well plates; flow cytometry data from plates 1 and 5 are shown as example delivery readouts.
  • Robust DNA Encoded Library (DEL) delivery in iPSCs and HeLa cells: Two vertical distribution/violin or bar-style plots labeled 'iPSC Boost' and 'HeLa Boost' with Control and Boost comparisons. The figure shows delivery efficiency of a fluorescently tagged DEL probe immediately after boosting, measured by flow cytometry, with boosted samples showing increased fluorescent signal relative to controls.
  • Automated in-line dispensing consistency (Plate 2 and Plate 7) and microscopy: A schematic of the consumable integrated with a robotic dispenser, small plots for dextran delivery across Plate 2 (wells 97–192) and Plate 7 (wells 577–672), and phase-contrast microscopy images at 10 minutes and 24 hours post-boost. The figure demonstrates automated dispensing of boosted HeLa cells into pre-loaded plates with flow cytometry delivery data and images showing cell morphology at early and later timepoints.
  • Macrocycle delivery to HeLa cells dose response: A workflow diagram showing HeLa cells boosted with no cargo then pipetted into wells pre-loaded with FITC-labeled macrocycle at concentrations 0–96 µM, accompanied by flow cytometry histograms and bar plots comparing Control and Boost. The figure illustrates a dose-dependent delivery response measured after mechanoporation.
  • Macrocycle delivery to HEK293 cells (flow and microscopy): A bar chart comparing 'Untreated' and 'Boost' samples for macrocycle delivery to HEK293 cells, alongside fluorescence and transmitted-light microscopy images for untreated and boosted samples. The images show FITC fluorescence in boosted cells and the bar chart indicates higher percent-positive signal after boosting.
  • Intracellular protein detection with LgBiT/HiBiT and LC-2 PROTAC: Conceptual diagrams showing an endogenous HiBiT-tagged protein, delivery of LgBiT to restore luminescence, and loss of signal upon degradation, plus a bar chart of luminescence versus LC-2 concentration (0–10 µM). The figure presents an assay where MiaPaCa-2 KRAS(G12C)-HiBiT cells treated with PROTAC LC-2 show decreasing luminescence after mechanoporation of LgBiT and Nano-Glo detection.
  • Intracellular target engagement BRET assays with impermeable tracer and inhibitors: Two small plots—one showing BRET signal as a function of impermeable kinase tracer concentration (top) and another showing BRET response after incubation with Src inhibitors (Ponatinib or Bosutinib) followed by mechanoporation with tracer (bottom). The figure depicts how mechanoporation introduces impermeable tracers into SRC-NanoLuc-expressing HeLa cells and how BRET is measured to assess tracer binding and inhibitor engagement.
  • Mechanoporated mRNA versus digitonin-permeabilized control BRET profiles: Grouped bar charts comparing BRET signals from NanoLuc mRNA introduced by mechanoporation or by digitonin permeabilization. The figure shows that the BRET profiles are similar between mechanoporated and digitonin-permeabilized samples according to the plotted results.

The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.