Presentation · 2025 · Meeting on the med

Publication

Cells
T cells, PBMCs, Cancer Cell Lines
Cargos
mRNA, CRISPR RNPs, circRNA

What this document says

The document, titled PORTAL and presented by Anil Narasimha, PhD (Chief Commercial Officer) on April 16, 2025, outlines a mechanoporation-based platform for intracellular delivery that aims to address cell permeability challenges across many cargo types and cell types. Slides describe the Portal approach (mechanical disruption via consumable cartridges and instruments), product lines across research to clinical scales, growth/partnerships, and comparative advantages versus viral/LNP and electroporation methods. Multiple data slides provide initial proof-of-concept results showing efficient mRNA expression, multiplexed cargo delivery, delivery across mixed PBMC populations, and preservation of cell function (T cells, CD34+ HSCs, iPSCs) following mechanoporation, with supporting heatmaps, bar charts, flow cytometry plots, and tables summarizing gene misregulation and functional readouts.

OVERVIEW OF THE PROBLEM AND THE PORTAL SOLUTION

Cell permeability is presented as a major challenge for delivering diverse cargos (CRISPR, peptides, RNA, DELs, heterobifunctional molecules, DNA, proteins) into cells. Portal's solution is a simple, scalable mechanical disruption (mechanoporation) approach in which cells and cargo are combined, passed through a membrane-like device to transiently porate cells, and emerge with intracellular cargo. The slides state the approach is applicable for cell therapies, fundamental research, and bioproduction and reference prior literature.

Portal Solves this Problem with a Simple, Scalable Approach

Portal describes a three-part schematic: input (patient- or donor-derived cells and cargo such as RNA, CRISPR, protein, small molecules), a mechanical disruption step (cells and cargo flow through a device/cartridge to porate cells), and resulting intracellular delivery. The company positions the approach as integratable across scales and compatible with various cell types and cargos.

Portal’s Growth To Date

The document lists senior team members and summarizes prior company experience and fundraising. It notes 50+ partners including research and cell therapy organizations and presents product concepts across scales: research, high-throughput, and clinical instruments and consumables intended to serve different user needs.

OUR APPROACH: MANUFACTURING AND PRODUCTION

A comparative chart contrasts viral/LNP approaches, electroporation, and Portal across features such as integratability, cell health preservation, scalability, universality across cell types and cargos, and multiplexed delivery. Portal's column is indicated as positive across all features while the other approaches show limitations in some areas. The slide also notes backward compatibility with systems initially developed using electroporation or mechanical methods.

Current Transfection Technologies Have Many Limitations

A 2x3 grid maps cell types (model cell lines vs patient-derived cells) against cargo classes (DNA, mRNA/siRNA, proteins/small molecules) and lists conventional technologies available in each intersection. The grid illustrates that model cell lines have multiple delivery options (LNP, virus, electroporation) whereas patient-derived cells have fewer options (primarily virus or electroporation), and delivery of proteins/small molecules is under-served in some intersections.

Portal Excels Where Others Struggle

The same cell-type by cargo matrix is shown with Portal highlighted as covering nearly all intersections, indicating the platform is capable of delivering DNA, mRNA/siRNA, and proteins/small molecules into both model and patient-derived cells.

Mechanical Delivery Has Limited Non-specific Impact on Normal T Cell Function

Comparative data are presented showing electroporation induces extensive gene misregulation in T cells at 6 and 24 hours, whereas mechanoporation shows far fewer changes and a profile more similar to control. A proliferation bar chart indicates that mechanoporation preserves normal T cell proliferation (similar to control), whereas electroporation reduces proliferation. A table quantifies numbers of misregulated genes at multiple FDR q-value thresholds, with electroporation showing thousands of changes at permissive thresholds and mechanoporation showing far fewer or zero changes at stricter thresholds.

Mechanical Delivery Preserves Stem Cell Function & Enables Rapid Cell Manipulation

Data for CD34+ cells and iPSCs mirror the T cell findings: electroporation shows more gene misregulation than mechanoporation. A spleen chimerism bar chart indicates mechanoporation supports efficient HSC engraftment without rest, annotated as roughly a 3x difference relative to electroporation. For iPSCs, stemness factor levels (Oct4, Nanog, Sox2, TERT) are preserved after mechanoporation and housekeeping gene expression is not disrupted.

What the figures show

  • A central cartoon cell surrounded by labels/icons for CRISPR, Peptides, RNA, DELs, Heterobifunctional, DNA, and Protein with arrows pointing toward the cell. This schematic shows the range of molecular cargos that need to enter cells and uses arrows to indicate movement toward or into the cell, illustrating the general challenge of cell permeability for diverse cargos.
  • A three-panel schematic labeled CELLS AND CARGO, MECHANICAL DISRUPTION, and INTRACELLULAR DELIVERY: the left panel lists cells (patient or donor-derived) and cargo types (RNA, CRISPR, protein, small molecules); the middle panel shows cells and cargo flowing through a purple oval membrane-like device representing mechanical disruption; the right panel shows cells after treatment with cargo inside. The diagram conveys that combining cells and cargo and passing them through a mechanoporation device yields intracellular delivery.
  • Three stylized instrument illustrations labeled Research, High Throughput, and Clinical representing product offerings across scales. The images compare benchtop research units, automated high-throughput integrations, and clinical manufacturing equipment to indicate a product pipeline that spans small-scale research to clinical manufacturing and integration.
  • A three-column comparison chart contrasting Viral/LNP, Electroporation, and PORTAL’S APPROACH across features (integratable with other systems, cell health preservation, scalability, universal across cell types + cargoes, multiplexed delivery). Icons and symbol marks indicate Portal as performing positively across all features while the other approaches have mixed or limited performance, visually communicating Portal's claimed advantages for integration and cell health.
  • A 2x3 grid mapping CELL TYPES (model cell lines vs patient-derived cells) against CARGO classes (DNA, mRNA/siRNA, proteins/small molecules) with listed technologies in each intersection (e.g., LNP, Virus, Electroporation). The matrix highlights which conventional methods are typically used for each cell/cargo pairing and visually shows gaps (notably for proteins/small molecules and patient-derived cells).
  • The same cell-type by cargo matrix overlaid with green shading across nearly all intersections and a purple 'POWERED BY PORTAL' badge. This figure communicates that Portal is presented as broadly capable of delivering DNA, mRNA/siRNA, and proteins/small molecules into both model and patient-derived cells.
  • Three comparative visual elements showing impacts on T cells: (1) heatmaps contrasting gene expression misregulation for electroporation (many colored bands) versus mechanoporation (mostly unchanged) at 6 and 24 hours, indicating electroporation causes widespread transcriptional changes while mechanoporation is more similar to control; (2) a proliferation bar chart ('Cells after 7 days activation') with Control and Mechanoporation bars high and similar and Electroporation lower, annotated with '16x' to indicate a large difference; (3) a table of FDR q-value thresholds listing numbers of misregulated genes for pairwise comparisons (Electroporation vs Control and Mechanical Delivery vs Control at 6hr and 24hr), showing substantially more misregulated genes after electroporation than mechanoporation across thresholds.
  • A set of panels for stem/progenitor cells: (1) heatmaps for CD34+ cells showing much greater gene misregulation after electroporation than mechanoporation at 6 and 24 hours; (2) a small 'Spleen chimerism' bar chart indicating mechanoporation supports HSC engraftment without rest and showing an annotated ~3x difference favoring mechanoporation over electroporation; (3) iPSC data including a bar plot of fold change for stemness genes (Oct4, Nanog, Sox2, TERT) showing preservation after mechanoporation and a CT-value plot showing no disruption of housekeeping genes, together implying preservation of stem cell function following mechanoporation.
  • A slide header 'IMPLEMENTING THE PORTAL SOLUTION' (no additional diagrammatic content on the slide).
  • A three-column product schematic showing R&D Scale (benchtop instrument), High Throughput Integrations (robotic-compatible 'Powered by Portal' consumables), and Clinical Scale Integrations (manufacturing-compatible consumables). Availability notes indicate R&D and high-throughput are available now for early adopters and GMP readiness for clinical scale is targeted Q1 2025.
  • Photograph and diagram of research-scale components: Gateway™ (a compact bench-top unit with a small consumable shown) and MicroBooster™ (a consumable delivery cartridge with dimensions ~18mm x 35mm and an inset showing cores with defined pore sizes). The image set conveys a benchtop instrument that controls delivery parameters and a cell type–specific cartridge containing pore-defined cores for mechanoporation.
  • Unstimulated T cell delivery figures: viability bar chart (Control ~95% live, Boost ~80% live), GFP expression bar chart (% GFP+ live cells showing Control 0% and Boost ~93%), and a flow cytometry histogram showing a GFP-positive population in the Boost condition. These panels show high GFP expression following mRNA delivery with modest viability reduction relative to control.

The summary and sections were read from the page layout. They are not a word-for-word extract, and they include only what was visible.