High-Throughput Next-Gen Live Cell Assays
Overview
A Portal and Merck HighRes Collaboration
Learn how Portal's integration with the HighRes PreciseDrop II (PDII) is transforming drug discovery—featuring real-world results from Merck.
In this webinar
What You'll Learn:
- How Portal's in-line mechanoporation solution integrates with the HighRes PDII
- Real-world implementation results from Merck's drug discovery workflows
- Practical considerations for transitioning from biochemical to live-cell assays
- Key applications: target engagement, DEL screening, PROTAC monitoring
Speakers
- Armon Sharei, Ph.D., Founder and CEO
- Xi Ai, Principal Scientist at Merck
- Drew Glatczak, Account Manager at HighRes Biosolutions
Full transcript
Thank you everyone for joining. A special thanks to she and Drew from our partners for joining and uh we [clears throat] were going to start with giving a technology overview on the portal side with the new capabilities of the platform and then hand it over to Xi to give a sense for how Merc has been using it across different applications and then finally to Drew to give a better sense for with our partnership with high-res how we can uh expand this to larger high throughput scales. Uh so the main problem that we're trying to solve for at portal is the basic issue of how do you put materials into cells?
Cells are the little machines that make everything happen in the body. If you can put whatever you want in them, now you can start to measure all kinds of things and try to engineer those cells for different functions. The way our system works is quite simple. We basically take the cells, mix it with whatever cargo we're trying to deliver, and then we run it through what looks like a fancy filter. So it's a thin piece of silicon with holes in it.
The holes are designed to be slightly smaller than the cell. So as the cell goes through, they get mechanically disrupted and that disruption stays open for about 30 seconds during which any material that's outside can simply diffuse into the cytoplasm of a cell. And to give you a sense for scale, for example, a 7 micron T- cell is going to go through a 5 micron hole. Uh we started the company about 3 years ago. At this stage, uh we have our researchbased systems, high throughput systems and clinical based systems. We won't really chat about the last one, but contact us for questions if you're wondering about clinical scale. Uh and at this point, we have over 75 partners across various use cases. Now, thinking taking a step back and thinking broadly about delivery, uh and we had a review in nature back in 2016 in case anyone wanted to read more. Uh but if you think about this matrix of what are the
different cell types you're working with versus different cargos, there are some things that are relatively easy to do. So delivery of nucleic acids like DNA and RNA into cell lines tends to be pretty easy. Hence this green zone. Once you transition into primary cells, it starts to get more difficult where there's things you can't do can do, things you can't do. Cells get mad at you because they don't like getting electroprated or being exposed to viruses. And that's this yellow zone over here. And finally, in that last column, there's kind of this red zone where anything that's not a nucleic acid, like proteins, peptides, and permeable small molecules start to get extremely difficult to put into cells reliably because they're not as chemically uniform as DNA and RNA, and they don't have a uniform negative charge the way DNA and RNA do. in the context of portal because we're just disrupting the membrane and now anything
that's outside can diffuse in. You can deliver virtually anything you want into the cytoplasm of a cell whether it's a small molecule, a peptide, a piece of RNA or DNA. Our one weak point however in that yellow zone of DNA is that we don't directly enable nuclear entry. So if you deliver DNA, it would go to the cytoplasm and you would need a chaperone or something to pull it back into the nucleus. uh if it's something like crisper, they tend to have nuclear localization sequences on them. They'll go in and do their edit anyway.
And the other nice thing we've seen with our platform is that we seem to keep cell function fairly normal. Um so if you're looking at the far left for tea cells, for example, if you do mechanical delivery versus electroparation, you would see that with mechanical delivery, they still proliferate normally. or with hematopoetic stem cells uh they can still engraft normally after treatment in an animal whereas with electroparation they don't. And this all comes down to gene expression which you can see on the far right where in our past papers we had shown with methods like electroporation if you look at the gene expression profile and compare it to an untreated cell you get a lot of disregulation of gene expression. So in these maps, black means nothing changed.
Red or green means there was significant up or down regulation. And we do see a lot of disregulation with electropation. Whereas with mechanical delivery, we seem to keep the cells fairly normal. And there's been a wide application set we've been exploring. So we'll hear more from our partners at Merc about this. But one of them has been uh probing of intracellular interactions where because we can deliver a lot of probe molecules into cells, you can now measure things inside of a cell that weren't possible without killing them. Uh and we can deliver a lot of impermeable molecules into cells. So now you can measure activity and understand the dynamics of your uh misbehaving small molecule or peptide before you go through any med optimization.
And in addition to that, a more recent area where we announced a partnership with Harvard's Reagan Institute and Microsoft on uh two weeks ago is generation of data for training AI models where if you think about the status quo on the left, often people are doing some kind of crisperbased screen where they're doing a single perturbation at a time and measuring many different properties of the cell. Whereas in our case, we enable multiple perturbations to happen simultaneously.
So now you can create much more complex data sets that can better uh train a model and help it deconvolute the complicated pathways inside a cell because if you only change one thing at a time, there's a lot of complexities you'll never be able to unravel. Uh but if you can change multiple things within a cell at a time, you can now better understand the underlying systems and generate a much more powerful model uh of the approach.
And uh from a bigger picture perspective, we believe that portal can provide a great platform for doing all kinds of drug [clears throat] screening or AI uh data generation because on the one hand we're pretty universal across cell type and cargo. So the platform has worked with every mamleian cell type we've ever tried and regardless of cargo chemistry or composition, you generally will be able to deliver it to the cytoplasm. Uh secondly, it's fairly easy to integrate our cartridges with existing robotics and existing automation systems. So obviously today we're uh really emphasizing our work with the team at Hyres, but uh there's many other systems that we've shown the portal technology can tie into where we kind of try to be an intel inside to other systems. And finally from a scaling perspective uh you'll see as we go through how we scale portals approach that we believe we can be quite
costefficient at large scale where the cost per sample can be uh a few orders of magnitude below alternatives like electropriation which means uh data generation at scale does not need to be cost prohibitive. Now there's four different scales at which we've been implementing portal. Today we're probably just going to talk about the first two. Uh but there are the research scale systems and then we also have our high throughput versions and clinical scale versions. Uh and we actually have a uh significant contract with DARPA where we're generating uh [clears throat] field deployable cell therapy systems where you can actually create cell therapies out in the field uh within a matter of minutes.
For our research scale system uh it's a fairly basic unit. So that's what you see depicted on the left. This fits in a standard biosafety hood. And this unit essentially controls the pressure at which material will go through the cartridges which you see right next to it. And these cartridges are what contain those silicon membranes. Um so in that bottom right you can see an SEM of these silicon membranes where it's basically a uniform set of holes that the cells are going to transit through.
uh and it's all ultimately a fairly [clears throat] simple process that allows you to do delivery for the smaller scale. And just to give a few examples from our past work, so this is one of our publications we had with our partners at Fizer where we were showing that if you have impermeable small molecules, you can actually use mechanical delivery to just insert them into cells. Uh and so in this bar chart you can see that without delivery you won't get inhibition of the target pathway. With the delivery you can now screen against which of these compounds seems to be most effective if it were inside a cell and thereby allow you to select for activity uh without having optimized permeability yet. And now in this case, you know, compound number five would have been the most interesting one to take towards medkim optimization for generating a permeable analog.
We've also shown you can apply it in other areas like Dell screening uh where in the context of Dells uh the small molecule that you're studying might be permeable to a cell but the DNA tag most certainly isn't. And this is why Dell screens are almost all done in lysates or biochemical context. Whereas we've been showing through other partnerships that you can actually deliver Dells into cells and now try to do live cell Dell screens uh which can give you much more information on your molecules binding because it would be in the context of a live cell and the cytoplasmic environment as opposed to a more artificial lysate or biochemical context.
And beyond that, we've also shown that you can deliver various probes into cells. So we collaborate a lot with our partners at Promega where there are different types of reagents that [clears throat] normally one would have used in a lysate or biochemical context, but we actually enable live cell uh screens. In this case, we were showing delivery of four different antibodies simultaneously for a luitt kit. So there are two primary antibodies that bind different parts of a phosphorolated BTK and then two secondary antibodies that have the different pieces of the lumit tag on them which when they complex will form a complete enzyme that can generate a luminescent signal and you can see in the bar charts on the right that the kind of standard protocol with a lysate will generate a certain signal. Uh in this case the preandidate treatment will induce phosphorilation. So that's the signal difference you're looking at. Uh
but we were showing in the far right on that bar chart that in a live cell you can also get a similar signal to noise ratio. And now without killing a cell you can measure phosphorilation levels of an untagged protein uh inside the cell. And we think this helps open up a lot of new this is an example of how you can open up a lot of new assaying capabilities by delivering different probes into cells. And then uh she who's on will probably talk a bit more about what they've been using it for at Merc.
And we've also applied this to primary cells quite a bit uh where just as an example over here we're showing T-C cells uh where you're delivering multiple cargos simultaneously. So in this case we were co-delivering a sugar polymer, a crisper R&P complex and a piece of mRNA all at the same time. And you can see from the bar chart on the right that you get about 85% double or sorry triple positive cells uh by doing this because it's just diffusion. So if one material goes in the rest will go in and you can see in the bottom left on the fax plots where all the cells that are expressing the mRNA for GFP are also knocked out for the B2M. So again verifying that if one cargo went in the rest also went in. And through other partnerships uh with places like MGH, we've been showing uh development of NextGen cell therapies uh where in this context they were delivering multiple circular RNAs into T- cells to kind of generate a transient
supercar and you can see from the bottom left fax plots that you can get a pretty high efficiency of multi-engineered tea cells that can ultimately be used for novel cell therapies. Now going towards how do we make this high throughput because we think we've shown a lot of diversity across cell types and cargos as far as what people can do in drug screening or looking at different cell engineering context. But how do you actually go and scale this?
And the mechanism we exploit for scaling this is we essentially try to integrate our cartridges in line with existing dispensers uh like the PD2 where where these dispensers are normally just um dispensing cells into a well we add a cartridge in between such that now as the cells go through they'll go through a membrane and get mechanically disrupted because the disruption lasts about 30 seconds you can actually just have the cargo in the well and so Now, as the cells exit, they'll just take up whatever is in the well. Uh, and you can do 5 to 10 plates per cartridge in this format. And to give you a more real sense for what the saw looks like, uh, the cartridge itself is quite small and is a little metallic attachment. And you can see from the video that the speed of operation remains fairly similar uh, to what you would have otherwise done even if the cartridge wasn't there. Uh, and the cartridge is simple to remove. So,
you're not permanently altering your device. You just put it on when you want to do delivery. When you don't want to do delivery, you can take it off. And we've shown that it can have fairly consistent performance uh across plates and across wells. So, the data on the left is showing a simple small molecule analog delivery and how across plates you can get fairly consistent uh delivery across the board. uh on the right side we're showing [clears throat] that for delivery of more complex molecules like mRNA you can similarly get uh pretty high viability as well as fairly high expression uh that's quite consistent well to well so the dots are pretty tight as far as their distribution and we've also been implementing this for crisper screens in some of our other partnerships where what you're looking at here we were co-delivering a dex strand as a tracer as well as a crisper R&P into T- cells uh primary human T-
cells and showing that you can maintain pretty strong uh viability throughout which is the graph on the left while also getting pretty robust knockout uh which is the graph on the right and the knockout efficiencies correlate pretty tightly with the labeled dextrand we're co-delivering. Um so you essentially have a built-in normalization that you can do with this. And finally, another point uh to point out is that because this is just diffusion, dose control is fairly straightforward. Uh so if you're looking at the plot with the histograms in the middle, you can see that as you increase the concentration of material outside the cells, more and more material will go into the cells and it is fairly linear. Uh so if you're trying to get a sense for dosing dynamics, you can do that in a fairly predictable way by just having uh different amounts of material in the different wells. And so for concluding the the portal intro portion,
uh we feel like we have a pretty strong universal system that can deliver virtually any material into any cell type, enabling all kinds of new applications across research scale and high throughput scales. Uh and with that I'll hand it off to Shei to chat about what they've been doing at Merc. Sure. Uh [clears throat] thank you for giving us this opportunity. So I will talk about what we have done at Merc for uh technology validation. Um give several examples of our applications and what we have learned as customer.
[clears throat] Um so we we um Armen already mentioned how important how important it is for us to deliver cargos into cells for drug discovery. Um but often time we have found that it's been challenging to reach the uh balance between good delivery efficiency and cell viability. Um that's was that was also the first question we asked when we were introduced about portal technology. Um you asked me to control the cell slides. Okay good. Um so so first validation we did was we want to see if we can deliver the cargo into cells still keep cells live and functioning and then we ask about scalability question and reproducibility.
So in terms of No, I can't control. I don't think I can control. Can you click? Yeah, thank you. Um, so first we we tested the the intracell the the first generation of gateway uh with over 14 different cell lines. the cell lines including IPSC's or immortalized cell cells and then we try to deliver proteins peptides mRNAs Chris RNPs and uh we we've pleased to to see that we've seen reliable delivery efficiency and cell viability um with most of tested cell lines giving an example here on the plot is a SPC1 cells that by com testing different combination of uh the pore size of the booster and the delivery uh pressure. we were able to find the optimal condition um that give us reasonable um viability and delivery efficiency and also uh we tested co- delivery of dextrin and peptides in this case and um as you can see that they show pretty consistent um efficiency efficiency. Uh with that said we we do
also find sometimes when the cells are in heterogeneous in size that will make it more challenging to um get high efficiency and high viability but that's for something we can work on later. Um so that's about the so we're happy with this um portal technology in terms of delivery efficiency and sale viability. Next next question we want to ask is if this scalable. Um so as Arma also mentioned that yeah they can do integrate a commonly used lab uh dispensers um with the technology and uh to to be able to deliver cargo in the high throughput manner. So here just list a brief timeline. As you can see, um, Porto has been working really efficiently by the time by the day they they, uh, receive our PD2 and within a month, they already [snorts] um finish the first integration and start to test in model cells and for another a month or so time, everything's completed, validated, and they're ready
to train us, help us do the on-site training. um meaning they come to our lab, help us install the instrument and we do the training um together. And if you can click on the next button. Yeah, as you can see in terms of reproducibility, this PD2 integrated PD2 delivery um quite consistent result uh in both 96 and 384 well format. And we also tested uh one of our peptides um in uh to did the concentration response curve um as you can see with when we did that with different booster or starting from different concentrations we got consistent EC50. So we were really happy with um all these three aspects. So next uh I'm going to just give you brief um examples yeah of how we apply portto technology. Um so first example is the early assessment of peptide intracellular function. Here we use the peptide we call it p-53 peptides. It actually it binds to M2M. uh uh that is the MDM um that is the um
negative regulator of p-53 in the P p-53 pathway. So once the peptides binds to this partner and p-53 get released and will be able to um form the hatchet and then trigger downstream um protein expression um and then this can be detected through uh betalacttomase um reporter gene. Um so what we did here we use um P50 uh we use portal uh PD2 to deliver um several peptides into HCT uh six HCT116 cells and we've um had really high cell viability um at set condition it's n over 90 90% and and over 70% of delivery efficiency. And as you can see on the plot on the top right and compared to uh non uh non-boosted condition, we do see increased activity with those impermable uh impermeable peptides when they're boosted. Um so next two examples, can you click again? Yeah. Are um the application in the target protein degradation.
So the first example on the left hand side um usually when we do um TPD um this degraders they they are large in size and the permeability can vary. So one one assay we use to uh evaluate the permeability of this uh degraders is to use VHL nanolook fused VHL have that express in the cells and then um we have a bod label tracer when these two get together um there's breath signal but if we add our um degrader this degrader would compete the binding um with the tracer and the signal will decrease. So but what we we did but usually this need you to have a um stably um expressed VHL nanolook um cell line. So what we did here is we directly deliver VHL nanolook mRNA to the um our model system ASPC1 cells. As you can see on the bottom left panel and you can see um when we measure the luciferous signal you can see very high expression of VHL nanolook and then when we add this VH 298 it is the uh VHL bind uh liant
um it can effectively compete against uh BB tracer and show the increase of um effect. Um so so that's one application on the right hand side is the application when we uh try to um assess the protein degradation kinetics with the degrader. Um usually what it this is done is that you have a cell line that um express protein of interest that has a high bit tag and a large bit. Um so and then after you add in the degrader uh we put them into it's live cell detection we put into spark and we can monitor the kinetics. In this case we directly use portal uh to deliver the degrader as you can see on the bottom. Um, compared to non-boosted cells, this degraders actually showed faster kinetics because they get into cells more quickly. So with portal delivery into the cells, it really simplified our degrader permeability and protein degradation kinetic assays. Um, so that's just a brief examples of what we have applied
portal technology um here. And if you go to next slides. So so far um we've had gateway for over a half one and a half year and PD2 integrated galaxy about half years. So what we have learned um we we've really and I I I'm so pleased to see that AR also showed this good correlation between cargo concentration and and cellular uh signals. Yeah, we we also saw the same thing when we try to deliver um CT labeled peptides in cascade cells and then you you can see the clear correlation and linear relationship between the concentration and the intensity of the fluorescent. So that can help us estimate how much of the of the cargo actually got in. And then we also um we are pleased because we you you can play with the the pore uh the booster pore size and you can play uh and and also the pressure that give us flexibility to find the the best conditions that can deliver cargo while still achieving um cell viability and
and I have to give shout out to Armon's team and portal is really the provider excellent tech support and um uh collaborative spirit. So make it easy for us to um troubleshoot um to get good reproducibility and certainly we also have learned some lessons. If you can click on next button, right? And as I already mentioned that cell population of heterogeneous size seem to be more challenging also with PD2 integration.
Uh right now we seem to have a limit of pressure that can make this kind of uh direct translate from gateway conditions less strict straightforward. But I just talked to Drew and we can connect and try to figure out how how how we can um work on this pressure thing. Um so and if you can click on next. Yeah. And we also have some additional plant applications uh including crisper guide delivery into primary cells to to least disturb overall um uh transcriptto mix profile and also facilitate target validation through delivery of things like antibodies peptides to XVable models to get the early read or or faster rate on on on on on the targets.
Yep, that's all I have. All right, thanks and Drew, [clears throat] I'll hand it off to you. Awesome. Awesome. Well, thank you all so very much. Um, it's always exciting seeing all the new areas and applications where our instrumentation uh can really assist and help uh produce results. Um, couldn't go to the next slide, please. All right. So, a little bit about the Precise Drop 2, also known as the PD2. It is a non-cont uh liquid dispenser um that's really used ac across a wide range of different workflows um and areas such as NGS library prep, PCR plate preparation, cellbased assays, and DOE's. Uh with dispense volumes down to 15 naniters, it can really help uh enable miniaturization and save that cost per sample.
It can help accelerate your scientific discovery by dispensing at lightning great uh speeds. If you look at this video right next to it, you can just see a booking across that plate dispensing the reagents. And then finally, it can help you cons uh conserve precious reagents with very low next to nothing dead volumes. Next slide, please. So the PD2 is used to be is designed to be used by everyone across any types of labs. Um it is designed with access accessibility in mind. So for those simple workflows, it's as simple as walking up, selecting the wells you want to dispense at, entering the uh volume and then running. For more complex workflows with variance uh gradients of volumes and concentrations, you have the ability to import plate plate maps uh via CSV files.
Next slide, please. uh a little bit over the PD2. It's very flexible. Uh as I just mentioned earlier, it can dispense all the way down to 50 naniters all the way up to hundreds of microL. It can work across various 96, 384, and 1536 volt plates. It can have up to eight channels and be configured for 1 to eight different types of liquids or reagents. It's precise with a CV of less than 2%. It can work with a wide range of source bottles. Um, we also have uh low volume options as well. A wide range of reagents uh compatible with cells as we just discussed as well as aquous liquids and other viscous reagents. And it's also designed to be a standalone walkup device or integrated into a more complex uh work cell system.
Go ahead. Next slide, please. Just really to uh touch on a a couple different areas where the PD2 excels at. Um, two of those within the genomics field are NGS sequencing library prep as well as qPCR plate prep uh for the dispensing of your master mixes, primers, buffers, uh, and probes. Uh, this is what really allows you to achieve those miniaturaturizations and get down to quarter or even eighth volume reactions depending upon the chemistry that you're running. Next slide.
And then finally within different types of drug discovery assay such as cell-based assays uh uh essay development DOE's complex uh type of plate map workflows compound dose response and then as well as a high throughput screening. Go on to the final slide. Um that's a little bit of the PD2. If you'd like to learn more about the instrument, you can scan that QR code right there on the screen. Otherwise, we will be at SLAS next week.
So uh please stop by our booth. We'd love to chat more. Thank you all so much for having me today. All right. Thanks, Drew. Um, and yeah, [clears throat] please feel free to submit any questions to the chat. Uh, it looks like there's some already in the Q&A, so we'll just take them. Uh, all right, let's see. So, we have one. Uh, what's the limit? What limits the number of cells and place per cartridge? Uh, do they eventually clog? And if so, would a pref filter be helpful? Um, so yes, the fil the uh the membranes do eventually clog. uh that is what limits their lifetime. Uh again on the order of five to 10 plates per cartridge is kind of a good starting point but it becomes workflow dependent. You can probably go above that in a number of these cases.
Uh using things like a 40 micron or 70 micron cell strainer for your sample before running it can help prolong the life of the cartridges. Uh I wouldn't bother putting that in line. Uh so those are that's how I would think about it. But in the end, you can get a few plates through per cartridge. Or if you have a multi- head dispenser, then I would just multiply how many you can do. So if you have four heads, you can now probably do 20 to 40 plates per cartridge.
Um, have we tried this with neurons? Uh, so uh, in our academic days, there were a few cases where freshly isolated neurons, um, I think we had collaborators that ran it through and it was fine. Often the issue with neurons is that because they people are studying them in their adherent form with the networks that they've created, you don't want to put them in suspension. Um, so if it's a context where you can and do want to put your neurons in suspension, then it would probably be fine. Uh, if you're not going to do that, then that would be a problem because the cells have to be in suspension uh to run through the system.
And then uh does the density of the cells uh impact the cargo uptake? Not really. It's pretty flexible. Um so you know anywhere from like the 2 million per mill to 50 million per mill range tends to be fine. Uh I would think of it as the cells are ultimately a very small volume percentage of your buffer. So they do not really deplete the available cargo unless you go to insane uh volume. So the short answer is it's not that dependent on cell concentration. Yeah, it's also our experience and we actually if we want to directly from delivery go to the functional assays we tend to use less cells less condensed cells and we found the uh efficiency can and delivery efficiency can be translated from when we when we have a lot of cells and benefit is when we use less cells and this cartridge can last longer.
Yeah. Uh and then as far as what other types of liquid handlers can we integrate with? So uh the PD2 is definitely one of our preferred platforms. The Certis flex from Nano also works quite well. Uh we've also done the GNF in the past. Uh we've also worked in other contexts with things like the Evanorf EP Motion or Integra Welljet. So there's a few different uh cases. is I mean feel free to reach out to our team if there's a specific case but uh the the PD2 is one that we really like the integration with uh because there's different systems have different caveats the PD2 is pretty good uh and then as far as how long are the cells permeable for after uh being squeezed it is on the order of 30 seconds it is a bit dependent on the exact cell type if you're running it in a different buffer etc ETA. Uh, but I would say ballpark 30 seconds. Uh, and if you those videos you saw of the inline integration of the Galaxy I with
the PD2, the delay between disruption to exposure to cargo is often under a second at that point. Uh, so we don't really worry about it. If you were trying to do something manual, that's where it becomes a consideration. Uh, all right. And then can multiple cartridges be attached to the multi- channelannel liquid handler dispenser nozzles allowing plating cells? Uh yes, you can do this in a multi- head format. So you have just one cartridge per nozzle is how I would think about it. Um so if you have a four head thing or eight head thing, you would just put them side by side.
Uh and then let me see here. uh can this be used for screening impermeable peptides? uh I think she or I don't know if you want to comment but I think you showed some data like that in terms of yeah right so if we we usually we use to validate the peptides we yield it from screening right and then um yeah and that's that's the advantage of PD2 integrated system and we can put the peptides on the plate and and get all the cells into into the plates.
Yeah. To activities. Yeah. Uh and then another question is how fast can this plate one 384 wall plate with the PD2? Actually, she you did that. I don't know if you have a sense for time. Yeah, it's it's just fast. And then we didn't really count time probably. Yeah. I think right. Yeah. All right. Under a minute. It's maybe um 96 definitely under a minute. 384 because we we we didn't do a lot of 384 but it's it's short. It's it because it didn't so what PD2 can do um to deliver 384 that's the time. So adding this this cartridge won't affect the speed. Let's put that way.
Yeah. All right, cool. Um, and then could it be used for CHO cells and B cells from mouse? Uh, yes, we've done cho cells quite a bit and uh we actually have some past publications related to B cell engineering with these mechanisms uh both in mouse and in human. Uh so yes, I don't believe we've done high throughput versions of mouse B cells, but it should probably be fine. Uh, can the cartridges be swapped out quickly? Uh, if you have them preloaded, it's pretty quick. Uh, or I don't know, she I'll let you comment because you guys are the direct user.
Um, yeah. Um, so right now for this PD2 cartridge, we we still need to assemble ahead of time. Um, so as Armenu said, if you already pre-assembled, it's easy swap. Um if you don't assemble take maybe a few minutes sometimes [clears throat] occasionally it will be leaking and then we have to adjust but I know you guys are having now disposable cartridges for PD2 right I mean for galaxy yeah so the disposable uh plastic versions uh they'll be coming in a few months uh and then the swap out becomes even faster uh and then we had another question can we integrate this instrument to full automation. The screw bottles are probably hard to automate. Uh Drew, I feel like that's more for you.
Yeah. Yeah. For for the screw bottles, for the type of reagent holders that it's compatible with, there is a wide uh range of sizes. So, if you need like a liter or multiple liters, you know, there are options that we can we do offer as well as explore. Um but for the screw caps, you know, it's one of the things you'll do on your preflight check, go through, load your reagents, ensure everything's good to go. Um and then just make sure that whichever reagent vessel you go with is enough to uh sustain the run.
All right. Um how do we see this applying for data generation for AI models? So uh I I think the main thing and we're newer to this space but we have a few partnerships there now that we've been learning as we go. But it appears that the two main themes are one of them is for people seeking to do crisper or RNA based perturbations of cells because we can deliver multiple of these cargos simultaneously into the same cell. It allows them to do a multiparametric perturbation of a cell so that now they get much much more useful information to feed into the models because if you can only vary one parameter at a time you often can't deconvolute complex processes. So what I mean is um if A plus B gives you C but you only change A or you only change B, you'll never see C. Um so you have to vary A and B at the same time to be able to see that. So that's one category. The other category for people that are more
interested in molecular models, it's more about giving them data sets that account for the cytoplasmic context of binding or kind of a multi-party binding event that's extremely hard to recreate in vitro. uh those are the contexts in which they seem to care about it. There's probably more things but it's not our expertise and we'll learn as we go. Uh is there any stress response due to delivery? Uh and does it confound biology? So I think as we were showing a little bit um earlier on in the slides uh if you look at the far right we do seem to keep cell function fairly normal. Uh so while if you squint there's some things that get disregulated it seems to keep it to a minimum. Uh so generally we think uh it should be a much cleaner results than alternatives.
Uh okay and then how efficient is co- delivery of multiple cargos? Uh quite efficient. Uh I think we had a slide somewhere where because it's just diffusion if one thing goes in the rest go in. Uh so in this context for T- cells we were able to simultaneously deliver three very different types of cargos. Um like an mRNA, a crisper complex and a sugar polymer have very little in common from a chemical composition standpoint. Uh but all three of them will go in together. So that can be quite efficient.
Um Drew, I think we had another question for you. In a fully integrated system, uh how are the source bottles and tubes for the PD2 changed or refilled? Yeah. So like the previous uh question regarding the screw caps, you know, you load before the run or after the run if it's uh and then can be kept on, you know, uh different types of cooling uh apparatuses. So if you need to maintain them chilled or warm or anything of the sort, you know, we can work with that to the side and off system. Um but yeah, you you typically just load enough for that run or if it is sensitive sorts of reagents you need to do like a swap or something you only have certain lifespan you need to change it you can then just build your protocols on whichever automation system you're utilizing to pause at a certain point notify the user to refill replace do whatever to the reagents before consuming the second part of the run.
Yeah. Uh and another question has this been done with hpatocy or hpatocy like cells? Uh I do believe we have partners that are doing it on hpatocytes. Uh obviously hpatocytes can be quite finicky to deal with. So it appears it's uh it can be quite dependent on how good a workflow and protocol and source you have for the hpatocytes. Um but it does appear to work. Um what's the delivery efficiency for oligos compared to traditional lipopectamine? Uh I would say it really depends on the cell type.
So something like a helila cell I mean lipopecttoine works quite well or probably similar. Um if you go to certain primary immune cells lipopfectamine is probably a nonoption whereas actually the data on the screen it works fairly well. The thing we've noticed that folks find most interesting for oligos is that because we just deliver the oligo directly to the cytoplasm, it provides the most unbiased screen um for oligo activity or different chemistries people are looking at because you don't need to account for the binding to the nanoparticle and endoome escape factors etc. uh because often the invivo delivery modality someone is using whether it's a conjugate or a different nanoparticle is not what they're using in vitro. Um so they can have artifacts from using nano particles but again depending on your system other techniques might work just fine. Um but for a lot of difficult cell types portal would probably have a
benefit. Uh does the volume of the cargo placed in the wells impact uptake? For example, does the cargo have to be dispensed in a concentrated amount in small volume in the wells prior to dispensing cells via the cartridge? Uh, I know G, do you want to take that? Um, if for usually for 96 well format, we put them into 40 microL 40. So 40 microL of cell drops into 40 microL. For 384, we put 166. Oh, 880. Huh? 8 + 8, right? eight micro liter into eight microL. Um we we haven't seen difference.
Great. Um does the cargo get delivered to cytool and avoid issues such as endooal uptake specifically for oligos? Uh yes, it's all directly to the cytoplasm. There is no endooal element. Uh it's a topic we explored quite a bit in our earlier papers. Uh so if you're ever interested, uh please shoot us a note. We're happy to share those. But yes, everything goes directly to the cytoplasm. There is no endooal elements. Uh and one example of that is for mRNA, we don't need the pseudouene modifications. Uh because we never go through an endoome. So unmodified RNA actually expresses quite well in our systems.
Um or before you go to next question, let me correct it. It's 16 plus 16 for 384, not just to set you up. For the next question, have you guys done 1536? No, we haven't. Um, yeah. Yeah, we haven't. Yeah, we haven't tried them internally either. Um, does 2% CV also apply to low end of dispensing volumes, which is 50 naniters. Uh, Drew, this might be more for you. Yep, it sure does. Um, and that's due to our ability to calibrate the dispense uh per reagent. So, it's uh more fine-tuned for that specific reagent to ensure um low CDs and reproducibility.
Yeah. Uh and Brian uh I see your comment. Thanks. Uh just need to bypass the relief valve and we can increase the pressure. So, she will uh we'll get that set up for you. Yeah, that'll be Thank you. And another question, is it compatible with the combi? Uh I believe we did do a quick pilot on a combi and it does look like you can do that. So the answer is probably uh we haven't formally implemented it for anyone but we did do a quick pilot and it looks like it can work. H uh if you want to reach out to us happy to chat more about the combi any data on the comparison of surface markers between T- cells transfected with traditional methods versus the portal method um yes we uh if you shoot us a note we can send you our we have a PNAS paper from 2018 which was doing a deeper dive on these um functional data we were showing uh on the far right over here uh we did not compare to LNPS and AAV we were primarily comparing to
electroporation uh but in general we do not appear to change the surface markers or cause non-specific activation or induce um kind of cytoine secretion that's not supposed to happen etc we genuinely seem to keep the tea cells in a unstimulated state um or rather we don't seem to non-specifically alter the state of the te- when we do this kind of delivery. Um, and actually some of our partners who study monocytes, they've been particularly keen on using this for studying more tolerogenic monocy and macrofase phenotypes because alternative delivery methods even if they work tend to drive them very strongly towards non-specific activation.
Um, and then what are some of the major application limitations? Honestly, the most common limitation uh we mention to people is the fact that if you're trying to deliver a plasmid, we're just going to put it in the cytoplasm. Uh therefore, plasmid expression is usually not very efficient. You would need a chaperone or something to be codelivered to pull that plasmid into the nucleus to get good expression. That's probably the major cargo limitation to be conscious of.
Again, the DNA will be in the cytoplasm, but if you want it to express, you need some you need to add something. Uh the major cell type limitation I would say is anything you can't take off a plate is not going to work. It needs to be in suspension uh for it to work. Yeah. And also as I mentioned like cells with different size. Yeah. Heterogeneous cell size or clumpy cells. Yeah. Yes. All right. Um, [clears throat] I think that was it as far as questions.
Um, she and Drew, thanks again a bunch for doing this. Uh, and look forward to all the work ahead together. And for everyone else listening, we'll have the recordings available, but also feel free to shoot us any questions if you have them. Thank you. Have a great rest of the day. Thanks, guys. Take care. Bye. Bye. Have a good SLS. Thank you. See you.
The transcript is the webinar's YouTube auto-generated caption track. It is included in full in the page HTML. Auto-generated captions can mishear names and technical terms.
# High-Throughput Next-Gen Live Cell Assays
This page is a text version of a Portal Biotechnologies webinar. The original page copy is followed by the full spoken transcript, so the recording can be read without playing the video.
## Webinar record
- Title: High-Throughput Next-Gen Live Cell Assays
- Original page: https://portal.bio/webinar02052026
- Text page: https://portal.bio/webinar02052026/transcript
- Markdown URL: https://portal.bio/webinar02052026/transcript.md
- Recording: https://www.youtube.com/watch?v=6O7Cgwnjc04
## Page content
### Overview
A Portal and Merck HighRes Collaboration
Learn how Portal's integration with the HighRes PreciseDrop II (PDII) is transforming drug discovery—featuring real-world results from Merck.
### In this webinar
#### What You'll Learn:
- How Portal's in-line mechanoporation solution integrates with the HighRes PDII
- Real-world implementation results from Merck's drug discovery workflows
- Practical considerations for transitioning from biochemical to live-cell assays
- Key applications: target engagement, DEL screening, PROTAC monitoring
### Speakers
- Armon Sharei, Ph.D., Founder and CEO
- Xi Ai, Principal Scientist at Merck
- Drew Glatczak, Account Manager at HighRes Biosolutions
## Full transcript
Thank you everyone for joining. A special thanks to she and Drew from our partners for joining and uh we [clears throat] were going to start with giving a technology overview on the portal side with the new capabilities of the platform and then hand it over to Xi to give a sense for how Merc has been using it across different applications and then finally to Drew to give a better sense for with our partnership with high-res how we can uh expand this to larger high throughput scales. Uh so the main problem that we're trying to solve for at portal is the basic issue of how do you put materials into cells?
Cells are the little machines that make everything happen in the body. If you can put whatever you want in them, now you can start to measure all kinds of things and try to engineer those cells for different functions. The way our system works is quite simple. We basically take the cells, mix it with whatever cargo we're trying to deliver, and then we run it through what looks like a fancy filter. So it's a thin piece of silicon with holes in it.
The holes are designed to be slightly smaller than the cell. So as the cell goes through, they get mechanically disrupted and that disruption stays open for about 30 seconds during which any material that's outside can simply diffuse into the cytoplasm of a cell. And to give you a sense for scale, for example, a 7 micron T- cell is going to go through a 5 micron hole. Uh we started the company about 3 years ago. At this stage, uh we have our researchbased systems, high throughput systems and clinical based systems. We won't really chat about the last one, but contact us for questions if you're wondering about clinical scale. Uh and at this point, we have over 75 partners across various use cases. Now, thinking taking a step back and thinking broadly about delivery, uh and we had a review in nature back in 2016 in case anyone wanted to read more. Uh but if you think about this matrix of what are the
different cell types you're working with versus different cargos, there are some things that are relatively easy to do. So delivery of nucleic acids like DNA and RNA into cell lines tends to be pretty easy. Hence this green zone. Once you transition into primary cells, it starts to get more difficult where there's things you can't do can do, things you can't do. Cells get mad at you because they don't like getting electroprated or being exposed to viruses. And that's this yellow zone over here. And finally, in that last column, there's kind of this red zone where anything that's not a nucleic acid, like proteins, peptides, and permeable small molecules start to get extremely difficult to put into cells reliably because they're not as chemically uniform as DNA and RNA, and they don't have a uniform negative charge the way DNA and RNA do. in the context of portal because we're just disrupting the membrane and now anything
that's outside can diffuse in. You can deliver virtually anything you want into the cytoplasm of a cell whether it's a small molecule, a peptide, a piece of RNA or DNA. Our one weak point however in that yellow zone of DNA is that we don't directly enable nuclear entry. So if you deliver DNA, it would go to the cytoplasm and you would need a chaperone or something to pull it back into the nucleus. uh if it's something like crisper, they tend to have nuclear localization sequences on them. They'll go in and do their edit anyway.
And the other nice thing we've seen with our platform is that we seem to keep cell function fairly normal. Um so if you're looking at the far left for tea cells, for example, if you do mechanical delivery versus electroparation, you would see that with mechanical delivery, they still proliferate normally. or with hematopoetic stem cells uh they can still engraft normally after treatment in an animal whereas with electroparation they don't. And this all comes down to gene expression which you can see on the far right where in our past papers we had shown with methods like electroporation if you look at the gene expression profile and compare it to an untreated cell you get a lot of disregulation of gene expression. So in these maps, black means nothing changed.
Red or green means there was significant up or down regulation. And we do see a lot of disregulation with electropation. Whereas with mechanical delivery, we seem to keep the cells fairly normal. And there's been a wide application set we've been exploring. So we'll hear more from our partners at Merc about this. But one of them has been uh probing of intracellular interactions where because we can deliver a lot of probe molecules into cells, you can now measure things inside of a cell that weren't possible without killing them. Uh and we can deliver a lot of impermeable molecules into cells. So now you can measure activity and understand the dynamics of your uh misbehaving small molecule or peptide before you go through any med optimization.
And in addition to that, a more recent area where we announced a partnership with Harvard's Reagan Institute and Microsoft on uh two weeks ago is generation of data for training AI models where if you think about the status quo on the left, often people are doing some kind of crisperbased screen where they're doing a single perturbation at a time and measuring many different properties of the cell. Whereas in our case, we enable multiple perturbations to happen simultaneously.
So now you can create much more complex data sets that can better uh train a model and help it deconvolute the complicated pathways inside a cell because if you only change one thing at a time, there's a lot of complexities you'll never be able to unravel. Uh but if you can change multiple things within a cell at a time, you can now better understand the underlying systems and generate a much more powerful model uh of the approach.
And uh from a bigger picture perspective, we believe that portal can provide a great platform for doing all kinds of drug [clears throat] screening or AI uh data generation because on the one hand we're pretty universal across cell type and cargo. So the platform has worked with every mamleian cell type we've ever tried and regardless of cargo chemistry or composition, you generally will be able to deliver it to the cytoplasm. Uh secondly, it's fairly easy to integrate our cartridges with existing robotics and existing automation systems. So obviously today we're uh really emphasizing our work with the team at Hyres, but uh there's many other systems that we've shown the portal technology can tie into where we kind of try to be an intel inside to other systems. And finally from a scaling perspective uh you'll see as we go through how we scale portals approach that we believe we can be quite
costefficient at large scale where the cost per sample can be uh a few orders of magnitude below alternatives like electropriation which means uh data generation at scale does not need to be cost prohibitive. Now there's four different scales at which we've been implementing portal. Today we're probably just going to talk about the first two. Uh but there are the research scale systems and then we also have our high throughput versions and clinical scale versions. Uh and we actually have a uh significant contract with DARPA where we're generating uh [clears throat] field deployable cell therapy systems where you can actually create cell therapies out in the field uh within a matter of minutes.
For our research scale system uh it's a fairly basic unit. So that's what you see depicted on the left. This fits in a standard biosafety hood. And this unit essentially controls the pressure at which material will go through the cartridges which you see right next to it. And these cartridges are what contain those silicon membranes. Um so in that bottom right you can see an SEM of these silicon membranes where it's basically a uniform set of holes that the cells are going to transit through.
uh and it's all ultimately a fairly [clears throat] simple process that allows you to do delivery for the smaller scale. And just to give a few examples from our past work, so this is one of our publications we had with our partners at Fizer where we were showing that if you have impermeable small molecules, you can actually use mechanical delivery to just insert them into cells. Uh and so in this bar chart you can see that without delivery you won't get inhibition of the target pathway. With the delivery you can now screen against which of these compounds seems to be most effective if it were inside a cell and thereby allow you to select for activity uh without having optimized permeability yet. And now in this case, you know, compound number five would have been the most interesting one to take towards medkim optimization for generating a permeable analog.
We've also shown you can apply it in other areas like Dell screening uh where in the context of Dells uh the small molecule that you're studying might be permeable to a cell but the DNA tag most certainly isn't. And this is why Dell screens are almost all done in lysates or biochemical context. Whereas we've been showing through other partnerships that you can actually deliver Dells into cells and now try to do live cell Dell screens uh which can give you much more information on your molecules binding because it would be in the context of a live cell and the cytoplasmic environment as opposed to a more artificial lysate or biochemical context.
And beyond that, we've also shown that you can deliver various probes into cells. So we collaborate a lot with our partners at Promega where there are different types of reagents that [clears throat] normally one would have used in a lysate or biochemical context, but we actually enable live cell uh screens. In this case, we were showing delivery of four different antibodies simultaneously for a luitt kit. So there are two primary antibodies that bind different parts of a phosphorolated BTK and then two secondary antibodies that have the different pieces of the lumit tag on them which when they complex will form a complete enzyme that can generate a luminescent signal and you can see in the bar charts on the right that the kind of standard protocol with a lysate will generate a certain signal. Uh in this case the preandidate treatment will induce phosphorilation. So that's the signal difference you're looking at. Uh
but we were showing in the far right on that bar chart that in a live cell you can also get a similar signal to noise ratio. And now without killing a cell you can measure phosphorilation levels of an untagged protein uh inside the cell. And we think this helps open up a lot of new this is an example of how you can open up a lot of new assaying capabilities by delivering different probes into cells. And then uh she who's on will probably talk a bit more about what they've been using it for at Merc.
And we've also applied this to primary cells quite a bit uh where just as an example over here we're showing T-C cells uh where you're delivering multiple cargos simultaneously. So in this case we were co-delivering a sugar polymer, a crisper R&P complex and a piece of mRNA all at the same time. And you can see from the bar chart on the right that you get about 85% double or sorry triple positive cells uh by doing this because it's just diffusion. So if one material goes in the rest will go in and you can see in the bottom left on the fax plots where all the cells that are expressing the mRNA for GFP are also knocked out for the B2M. So again verifying that if one cargo went in the rest also went in. And through other partnerships uh with places like MGH, we've been showing uh development of NextGen cell therapies uh where in this context they were delivering multiple circular RNAs into T- cells to kind of generate a transient
supercar and you can see from the bottom left fax plots that you can get a pretty high efficiency of multi-engineered tea cells that can ultimately be used for novel cell therapies. Now going towards how do we make this high throughput because we think we've shown a lot of diversity across cell types and cargos as far as what people can do in drug screening or looking at different cell engineering context. But how do you actually go and scale this?
And the mechanism we exploit for scaling this is we essentially try to integrate our cartridges in line with existing dispensers uh like the PD2 where where these dispensers are normally just um dispensing cells into a well we add a cartridge in between such that now as the cells go through they'll go through a membrane and get mechanically disrupted because the disruption lasts about 30 seconds you can actually just have the cargo in the well and so Now, as the cells exit, they'll just take up whatever is in the well. Uh, and you can do 5 to 10 plates per cartridge in this format. And to give you a more real sense for what the saw looks like, uh, the cartridge itself is quite small and is a little metallic attachment. And you can see from the video that the speed of operation remains fairly similar uh, to what you would have otherwise done even if the cartridge wasn't there. Uh, and the cartridge is simple to remove. So,
you're not permanently altering your device. You just put it on when you want to do delivery. When you don't want to do delivery, you can take it off. And we've shown that it can have fairly consistent performance uh across plates and across wells. So, the data on the left is showing a simple small molecule analog delivery and how across plates you can get fairly consistent uh delivery across the board. uh on the right side we're showing [clears throat] that for delivery of more complex molecules like mRNA you can similarly get uh pretty high viability as well as fairly high expression uh that's quite consistent well to well so the dots are pretty tight as far as their distribution and we've also been implementing this for crisper screens in some of our other partnerships where what you're looking at here we were co-delivering a dex strand as a tracer as well as a crisper R&P into T- cells uh primary human T-
cells and showing that you can maintain pretty strong uh viability throughout which is the graph on the left while also getting pretty robust knockout uh which is the graph on the right and the knockout efficiencies correlate pretty tightly with the labeled dextrand we're co-delivering. Um so you essentially have a built-in normalization that you can do with this. And finally, another point uh to point out is that because this is just diffusion, dose control is fairly straightforward. Uh so if you're looking at the plot with the histograms in the middle, you can see that as you increase the concentration of material outside the cells, more and more material will go into the cells and it is fairly linear. Uh so if you're trying to get a sense for dosing dynamics, you can do that in a fairly predictable way by just having uh different amounts of material in the different wells. And so for concluding the the portal intro portion,
uh we feel like we have a pretty strong universal system that can deliver virtually any material into any cell type, enabling all kinds of new applications across research scale and high throughput scales. Uh and with that I'll hand it off to Shei to chat about what they've been doing at Merc. Sure. Uh [clears throat] thank you for giving us this opportunity. So I will talk about what we have done at Merc for uh technology validation. Um give several examples of our applications and what we have learned as customer.
[clears throat] Um so we we um Armen already mentioned how important how important it is for us to deliver cargos into cells for drug discovery. Um but often time we have found that it's been challenging to reach the uh balance between good delivery efficiency and cell viability. Um that's was that was also the first question we asked when we were introduced about portal technology. Um you asked me to control the cell slides. Okay good. Um so so first validation we did was we want to see if we can deliver the cargo into cells still keep cells live and functioning and then we ask about scalability question and reproducibility.
So in terms of No, I can't control. I don't think I can control. Can you click? Yeah, thank you. Um, so first we we tested the the intracell the the first generation of gateway uh with over 14 different cell lines. the cell lines including IPSC's or immortalized cell cells and then we try to deliver proteins peptides mRNAs Chris RNPs and uh we we've pleased to to see that we've seen reliable delivery efficiency and cell viability um with most of tested cell lines giving an example here on the plot is a SPC1 cells that by com testing different combination of uh the pore size of the booster and the delivery uh pressure. we were able to find the optimal condition um that give us reasonable um viability and delivery efficiency and also uh we tested co- delivery of dextrin and peptides in this case and um as you can see that they show pretty consistent um efficiency efficiency. Uh with that said we we do
also find sometimes when the cells are in heterogeneous in size that will make it more challenging to um get high efficiency and high viability but that's for something we can work on later. Um so that's about the so we're happy with this um portal technology in terms of delivery efficiency and sale viability. Next next question we want to ask is if this scalable. Um so as Arma also mentioned that yeah they can do integrate a commonly used lab uh dispensers um with the technology and uh to to be able to deliver cargo in the high throughput manner. So here just list a brief timeline. As you can see, um, Porto has been working really efficiently by the time by the day they they, uh, receive our PD2 and within a month, they already [snorts] um finish the first integration and start to test in model cells and for another a month or so time, everything's completed, validated, and they're ready
to train us, help us do the on-site training. um meaning they come to our lab, help us install the instrument and we do the training um together. And if you can click on the next button. Yeah, as you can see in terms of reproducibility, this PD2 integrated PD2 delivery um quite consistent result uh in both 96 and 384 well format. And we also tested uh one of our peptides um in uh to did the concentration response curve um as you can see with when we did that with different booster or starting from different concentrations we got consistent EC50. So we were really happy with um all these three aspects. So next uh I'm going to just give you brief um examples yeah of how we apply portto technology. Um so first example is the early assessment of peptide intracellular function. Here we use the peptide we call it p-53 peptides. It actually it binds to M2M. uh uh that is the MDM um that is the um
negative regulator of p-53 in the P p-53 pathway. So once the peptides binds to this partner and p-53 get released and will be able to um form the hatchet and then trigger downstream um protein expression um and then this can be detected through uh betalacttomase um reporter gene. Um so what we did here we use um P50 uh we use portal uh PD2 to deliver um several peptides into HCT uh six HCT116 cells and we've um had really high cell viability um at set condition it's n over 90 90% and and over 70% of delivery efficiency. And as you can see on the plot on the top right and compared to uh non uh non-boosted condition, we do see increased activity with those impermable uh impermeable peptides when they're boosted. Um so next two examples, can you click again? Yeah. Are um the application in the target protein degradation.
So the first example on the left hand side um usually when we do um TPD um this degraders they they are large in size and the permeability can vary. So one one assay we use to uh evaluate the permeability of this uh degraders is to use VHL nanolook fused VHL have that express in the cells and then um we have a bod label tracer when these two get together um there's breath signal but if we add our um degrader this degrader would compete the binding um with the tracer and the signal will decrease. So but what we we did but usually this need you to have a um stably um expressed VHL nanolook um cell line. So what we did here is we directly deliver VHL nanolook mRNA to the um our model system ASPC1 cells. As you can see on the bottom left panel and you can see um when we measure the luciferous signal you can see very high expression of VHL nanolook and then when we add this VH 298 it is the uh VHL bind uh liant
um it can effectively compete against uh BB tracer and show the increase of um effect. Um so so that's one application on the right hand side is the application when we uh try to um assess the protein degradation kinetics with the degrader. Um usually what it this is done is that you have a cell line that um express protein of interest that has a high bit tag and a large bit. Um so and then after you add in the degrader uh we put them into it's live cell detection we put into spark and we can monitor the kinetics. In this case we directly use portal uh to deliver the degrader as you can see on the bottom. Um, compared to non-boosted cells, this degraders actually showed faster kinetics because they get into cells more quickly. So with portal delivery into the cells, it really simplified our degrader permeability and protein degradation kinetic assays. Um, so that's just a brief examples of what we have applied
portal technology um here. And if you go to next slides. So so far um we've had gateway for over a half one and a half year and PD2 integrated galaxy about half years. So what we have learned um we we've really and I I I'm so pleased to see that AR also showed this good correlation between cargo concentration and and cellular uh signals. Yeah, we we also saw the same thing when we try to deliver um CT labeled peptides in cascade cells and then you you can see the clear correlation and linear relationship between the concentration and the intensity of the fluorescent. So that can help us estimate how much of the of the cargo actually got in. And then we also um we are pleased because we you you can play with the the pore uh the booster pore size and you can play uh and and also the pressure that give us flexibility to find the the best conditions that can deliver cargo while still achieving um cell viability and
and I have to give shout out to Armon's team and portal is really the provider excellent tech support and um uh collaborative spirit. So make it easy for us to um troubleshoot um to get good reproducibility and certainly we also have learned some lessons. If you can click on next button, right? And as I already mentioned that cell population of heterogeneous size seem to be more challenging also with PD2 integration.
Uh right now we seem to have a limit of pressure that can make this kind of uh direct translate from gateway conditions less strict straightforward. But I just talked to Drew and we can connect and try to figure out how how how we can um work on this pressure thing. Um so and if you can click on next. Yeah. And we also have some additional plant applications uh including crisper guide delivery into primary cells to to least disturb overall um uh transcriptto mix profile and also facilitate target validation through delivery of things like antibodies peptides to XVable models to get the early read or or faster rate on on on on on the targets.
Yep, that's all I have. All right, thanks and Drew, [clears throat] I'll hand it off to you. Awesome. Awesome. Well, thank you all so very much. Um, it's always exciting seeing all the new areas and applications where our instrumentation uh can really assist and help uh produce results. Um, couldn't go to the next slide, please. All right. So, a little bit about the Precise Drop 2, also known as the PD2. It is a non-cont uh liquid dispenser um that's really used ac across a wide range of different workflows um and areas such as NGS library prep, PCR plate preparation, cellbased assays, and DOE's. Uh with dispense volumes down to 15 naniters, it can really help uh enable miniaturization and save that cost per sample.
It can help accelerate your scientific discovery by dispensing at lightning great uh speeds. If you look at this video right next to it, you can just see a booking across that plate dispensing the reagents. And then finally, it can help you cons uh conserve precious reagents with very low next to nothing dead volumes. Next slide, please. So the PD2 is used to be is designed to be used by everyone across any types of labs. Um it is designed with access accessibility in mind. So for those simple workflows, it's as simple as walking up, selecting the wells you want to dispense at, entering the uh volume and then running. For more complex workflows with variance uh gradients of volumes and concentrations, you have the ability to import plate plate maps uh via CSV files.
Next slide, please. uh a little bit over the PD2. It's very flexible. Uh as I just mentioned earlier, it can dispense all the way down to 50 naniters all the way up to hundreds of microL. It can work across various 96, 384, and 1536 volt plates. It can have up to eight channels and be configured for 1 to eight different types of liquids or reagents. It's precise with a CV of less than 2%. It can work with a wide range of source bottles. Um, we also have uh low volume options as well. A wide range of reagents uh compatible with cells as we just discussed as well as aquous liquids and other viscous reagents. And it's also designed to be a standalone walkup device or integrated into a more complex uh work cell system.
Go ahead. Next slide, please. Just really to uh touch on a a couple different areas where the PD2 excels at. Um, two of those within the genomics field are NGS sequencing library prep as well as qPCR plate prep uh for the dispensing of your master mixes, primers, buffers, uh, and probes. Uh, this is what really allows you to achieve those miniaturaturizations and get down to quarter or even eighth volume reactions depending upon the chemistry that you're running. Next slide.
And then finally within different types of drug discovery assay such as cell-based assays uh uh essay development DOE's complex uh type of plate map workflows compound dose response and then as well as a high throughput screening. Go on to the final slide. Um that's a little bit of the PD2. If you'd like to learn more about the instrument, you can scan that QR code right there on the screen. Otherwise, we will be at SLAS next week.
So uh please stop by our booth. We'd love to chat more. Thank you all so much for having me today. All right. Thanks, Drew. Um, and yeah, [clears throat] please feel free to submit any questions to the chat. Uh, it looks like there's some already in the Q&A, so we'll just take them. Uh, all right, let's see. So, we have one. Uh, what's the limit? What limits the number of cells and place per cartridge? Uh, do they eventually clog? And if so, would a pref filter be helpful? Um, so yes, the fil the uh the membranes do eventually clog. uh that is what limits their lifetime. Uh again on the order of five to 10 plates per cartridge is kind of a good starting point but it becomes workflow dependent. You can probably go above that in a number of these cases.
Uh using things like a 40 micron or 70 micron cell strainer for your sample before running it can help prolong the life of the cartridges. Uh I wouldn't bother putting that in line. Uh so those are that's how I would think about it. But in the end, you can get a few plates through per cartridge. Or if you have a multi- head dispenser, then I would just multiply how many you can do. So if you have four heads, you can now probably do 20 to 40 plates per cartridge.
Um, have we tried this with neurons? Uh, so uh, in our academic days, there were a few cases where freshly isolated neurons, um, I think we had collaborators that ran it through and it was fine. Often the issue with neurons is that because they people are studying them in their adherent form with the networks that they've created, you don't want to put them in suspension. Um, so if it's a context where you can and do want to put your neurons in suspension, then it would probably be fine. Uh, if you're not going to do that, then that would be a problem because the cells have to be in suspension uh to run through the system.
And then uh does the density of the cells uh impact the cargo uptake? Not really. It's pretty flexible. Um so you know anywhere from like the 2 million per mill to 50 million per mill range tends to be fine. Uh I would think of it as the cells are ultimately a very small volume percentage of your buffer. So they do not really deplete the available cargo unless you go to insane uh volume. So the short answer is it's not that dependent on cell concentration. Yeah, it's also our experience and we actually if we want to directly from delivery go to the functional assays we tend to use less cells less condensed cells and we found the uh efficiency can and delivery efficiency can be translated from when we when we have a lot of cells and benefit is when we use less cells and this cartridge can last longer.
Yeah. Uh and then as far as what other types of liquid handlers can we integrate with? So uh the PD2 is definitely one of our preferred platforms. The Certis flex from Nano also works quite well. Uh we've also done the GNF in the past. Uh we've also worked in other contexts with things like the Evanorf EP Motion or Integra Welljet. So there's a few different uh cases. is I mean feel free to reach out to our team if there's a specific case but uh the the PD2 is one that we really like the integration with uh because there's different systems have different caveats the PD2 is pretty good uh and then as far as how long are the cells permeable for after uh being squeezed it is on the order of 30 seconds it is a bit dependent on the exact cell type if you're running it in a different buffer etc ETA. Uh, but I would say ballpark 30 seconds. Uh, and if you those videos you saw of the inline integration of the Galaxy I with
the PD2, the delay between disruption to exposure to cargo is often under a second at that point. Uh, so we don't really worry about it. If you were trying to do something manual, that's where it becomes a consideration. Uh, all right. And then can multiple cartridges be attached to the multi- channelannel liquid handler dispenser nozzles allowing plating cells? Uh yes, you can do this in a multi- head format. So you have just one cartridge per nozzle is how I would think about it. Um so if you have a four head thing or eight head thing, you would just put them side by side.
Uh and then let me see here. uh can this be used for screening impermeable peptides? uh I think she or I don't know if you want to comment but I think you showed some data like that in terms of yeah right so if we we usually we use to validate the peptides we yield it from screening right and then um yeah and that's that's the advantage of PD2 integrated system and we can put the peptides on the plate and and get all the cells into into the plates.
Yeah. To activities. Yeah. Uh and then another question is how fast can this plate one 384 wall plate with the PD2? Actually, she you did that. I don't know if you have a sense for time. Yeah, it's it's just fast. And then we didn't really count time probably. Yeah. I think right. Yeah. All right. Under a minute. It's maybe um 96 definitely under a minute. 384 because we we we didn't do a lot of 384 but it's it's short. It's it because it didn't so what PD2 can do um to deliver 384 that's the time. So adding this this cartridge won't affect the speed. Let's put that way.
Yeah. All right, cool. Um, and then could it be used for CHO cells and B cells from mouse? Uh, yes, we've done cho cells quite a bit and uh we actually have some past publications related to B cell engineering with these mechanisms uh both in mouse and in human. Uh so yes, I don't believe we've done high throughput versions of mouse B cells, but it should probably be fine. Uh, can the cartridges be swapped out quickly? Uh, if you have them preloaded, it's pretty quick. Uh, or I don't know, she I'll let you comment because you guys are the direct user.
Um, yeah. Um, so right now for this PD2 cartridge, we we still need to assemble ahead of time. Um, so as Armenu said, if you already pre-assembled, it's easy swap. Um if you don't assemble take maybe a few minutes sometimes [clears throat] occasionally it will be leaking and then we have to adjust but I know you guys are having now disposable cartridges for PD2 right I mean for galaxy yeah so the disposable uh plastic versions uh they'll be coming in a few months uh and then the swap out becomes even faster uh and then we had another question can we integrate this instrument to full automation. The screw bottles are probably hard to automate. Uh Drew, I feel like that's more for you.
Yeah. Yeah. For for the screw bottles, for the type of reagent holders that it's compatible with, there is a wide uh range of sizes. So, if you need like a liter or multiple liters, you know, there are options that we can we do offer as well as explore. Um but for the screw caps, you know, it's one of the things you'll do on your preflight check, go through, load your reagents, ensure everything's good to go. Um and then just make sure that whichever reagent vessel you go with is enough to uh sustain the run.
All right. Um how do we see this applying for data generation for AI models? So uh I I think the main thing and we're newer to this space but we have a few partnerships there now that we've been learning as we go. But it appears that the two main themes are one of them is for people seeking to do crisper or RNA based perturbations of cells because we can deliver multiple of these cargos simultaneously into the same cell. It allows them to do a multiparametric perturbation of a cell so that now they get much much more useful information to feed into the models because if you can only vary one parameter at a time you often can't deconvolute complex processes. So what I mean is um if A plus B gives you C but you only change A or you only change B, you'll never see C. Um so you have to vary A and B at the same time to be able to see that. So that's one category. The other category for people that are more
interested in molecular models, it's more about giving them data sets that account for the cytoplasmic context of binding or kind of a multi-party binding event that's extremely hard to recreate in vitro. uh those are the contexts in which they seem to care about it. There's probably more things but it's not our expertise and we'll learn as we go. Uh is there any stress response due to delivery? Uh and does it confound biology? So I think as we were showing a little bit um earlier on in the slides uh if you look at the far right we do seem to keep cell function fairly normal. Uh so while if you squint there's some things that get disregulated it seems to keep it to a minimum. Uh so generally we think uh it should be a much cleaner results than alternatives.
Uh okay and then how efficient is co- delivery of multiple cargos? Uh quite efficient. Uh I think we had a slide somewhere where because it's just diffusion if one thing goes in the rest go in. Uh so in this context for T- cells we were able to simultaneously deliver three very different types of cargos. Um like an mRNA, a crisper complex and a sugar polymer have very little in common from a chemical composition standpoint. Uh but all three of them will go in together. So that can be quite efficient.
Um Drew, I think we had another question for you. In a fully integrated system, uh how are the source bottles and tubes for the PD2 changed or refilled? Yeah. So like the previous uh question regarding the screw caps, you know, you load before the run or after the run if it's uh and then can be kept on, you know, uh different types of cooling uh apparatuses. So if you need to maintain them chilled or warm or anything of the sort, you know, we can work with that to the side and off system. Um but yeah, you you typically just load enough for that run or if it is sensitive sorts of reagents you need to do like a swap or something you only have certain lifespan you need to change it you can then just build your protocols on whichever automation system you're utilizing to pause at a certain point notify the user to refill replace do whatever to the reagents before consuming the second part of the run.
Yeah. Uh and another question has this been done with hpatocy or hpatocy like cells? Uh I do believe we have partners that are doing it on hpatocytes. Uh obviously hpatocytes can be quite finicky to deal with. So it appears it's uh it can be quite dependent on how good a workflow and protocol and source you have for the hpatocytes. Um but it does appear to work. Um what's the delivery efficiency for oligos compared to traditional lipopectamine? Uh I would say it really depends on the cell type.
So something like a helila cell I mean lipopecttoine works quite well or probably similar. Um if you go to certain primary immune cells lipopfectamine is probably a nonoption whereas actually the data on the screen it works fairly well. The thing we've noticed that folks find most interesting for oligos is that because we just deliver the oligo directly to the cytoplasm, it provides the most unbiased screen um for oligo activity or different chemistries people are looking at because you don't need to account for the binding to the nanoparticle and endoome escape factors etc. uh because often the invivo delivery modality someone is using whether it's a conjugate or a different nanoparticle is not what they're using in vitro. Um so they can have artifacts from using nano particles but again depending on your system other techniques might work just fine. Um but for a lot of difficult cell types portal would probably have a
benefit. Uh does the volume of the cargo placed in the wells impact uptake? For example, does the cargo have to be dispensed in a concentrated amount in small volume in the wells prior to dispensing cells via the cartridge? Uh, I know G, do you want to take that? Um, if for usually for 96 well format, we put them into 40 microL 40. So 40 microL of cell drops into 40 microL. For 384, we put 166. Oh, 880. Huh? 8 + 8, right? eight micro liter into eight microL. Um we we haven't seen difference.
Great. Um does the cargo get delivered to cytool and avoid issues such as endooal uptake specifically for oligos? Uh yes, it's all directly to the cytoplasm. There is no endooal element. Uh it's a topic we explored quite a bit in our earlier papers. Uh so if you're ever interested, uh please shoot us a note. We're happy to share those. But yes, everything goes directly to the cytoplasm. There is no endooal elements. Uh and one example of that is for mRNA, we don't need the pseudouene modifications. Uh because we never go through an endoome. So unmodified RNA actually expresses quite well in our systems.
Um or before you go to next question, let me correct it. It's 16 plus 16 for 384, not just to set you up. For the next question, have you guys done 1536? No, we haven't. Um, yeah. Yeah, we haven't. Yeah, we haven't tried them internally either. Um, does 2% CV also apply to low end of dispensing volumes, which is 50 naniters. Uh, Drew, this might be more for you. Yep, it sure does. Um, and that's due to our ability to calibrate the dispense uh per reagent. So, it's uh more fine-tuned for that specific reagent to ensure um low CDs and reproducibility.
Yeah. Uh and Brian uh I see your comment. Thanks. Uh just need to bypass the relief valve and we can increase the pressure. So, she will uh we'll get that set up for you. Yeah, that'll be Thank you. And another question, is it compatible with the combi? Uh I believe we did do a quick pilot on a combi and it does look like you can do that. So the answer is probably uh we haven't formally implemented it for anyone but we did do a quick pilot and it looks like it can work. H uh if you want to reach out to us happy to chat more about the combi any data on the comparison of surface markers between T- cells transfected with traditional methods versus the portal method um yes we uh if you shoot us a note we can send you our we have a PNAS paper from 2018 which was doing a deeper dive on these um functional data we were showing uh on the far right over here uh we did not compare to LNPS and AAV we were primarily comparing to
electroporation uh but in general we do not appear to change the surface markers or cause non-specific activation or induce um kind of cytoine secretion that's not supposed to happen etc we genuinely seem to keep the tea cells in a unstimulated state um or rather we don't seem to non-specifically alter the state of the te- when we do this kind of delivery. Um, and actually some of our partners who study monocytes, they've been particularly keen on using this for studying more tolerogenic monocy and macrofase phenotypes because alternative delivery methods even if they work tend to drive them very strongly towards non-specific activation.
Um, and then what are some of the major application limitations? Honestly, the most common limitation uh we mention to people is the fact that if you're trying to deliver a plasmid, we're just going to put it in the cytoplasm. Uh therefore, plasmid expression is usually not very efficient. You would need a chaperone or something to be codelivered to pull that plasmid into the nucleus to get good expression. That's probably the major cargo limitation to be conscious of.
Again, the DNA will be in the cytoplasm, but if you want it to express, you need some you need to add something. Uh the major cell type limitation I would say is anything you can't take off a plate is not going to work. It needs to be in suspension uh for it to work. Yeah. And also as I mentioned like cells with different size. Yeah. Heterogeneous cell size or clumpy cells. Yeah. Yes. All right. Um, [clears throat] I think that was it as far as questions.
Um, she and Drew, thanks again a bunch for doing this. Uh, and look forward to all the work ahead together. And for everyone else listening, we'll have the recordings available, but also feel free to shoot us any questions if you have them. Thank you. Have a great rest of the day. Thanks, guys. Take care. Bye. Bye. Have a good SLS. Thank you. See you.
## Source note
The transcript is the webinar's YouTube auto-generated caption track. It is included in full in the page HTML. Auto-generated captions can mishear names and technical terms.