Portal & AbbVie: Unlocking Intracellular Insights for Drug Discovery

Overview

See how Portal and Promega are enabling AbbVie to test impermeable small molecules, protein degraders, and gene editing constructs directly inside living cells — bypassing traditional permeability limitations to accelerate early drug discovery decisions.

In this webinar

What You'll Learn:

  • How mechanoporation enables structure-activity relationship (SAR) studies for impermeable small molecules and protein degraders that can't cross the cell membrane on their own
  • How Portal delivers Promega's impermeable NanoBRET tracers to enable intracellular target engagement assays for mechanistic studies
  • How Portal facilitates CRISPR knock-in experiments to support functional genomics workflows
  • How Portal's technology platform provides a single solution spanning compound delivery, live-cell assays, and gene editing

Speakers

  • Armon Sharei, Ph.D., Founder and CEO
  • Milad Rouhimoghadam, Senior Scientist at Abbvie

Full transcript

Well, thank you everyone for joining. Uh I'm Arman Shere, founder CEO for Portal and uh excited to have Midad on with us as well to chat about uh what we've been up to with uh Portal and the team at ABV. So we're going to start off with a quick overview of uh Portal and what our technology background is and then I'll hand it over to Mid to chat about some of the latest on what he's been working on with us. So the key problem we want to solve for at portal is how do you deliver various materials make into the body and if you can put whatever you want in them how you probe for different functions and use it for drug discovery in addition to engineer those various cell functions uh to gain insights into different biologies or implement it for cell therapies.

The way our technology works is quite simple. uh if you're going from left to right on the graphic, we take cells, mix it with whatever cargo we're trying to deliver, and then we run it through what looks like a fancy filter. So, it's a thin piece of silicon with holes in it. The holes are designed to be slightly smaller than the cell. So, as the cells go through, they get mechanically disrupted. Uh that disruption lasts for about 30 seconds, and during that window, any material that's outside can simply diffuse into the cell, and the cells will then uh contain that material after they seal back up. So a ridiculously simple way to put virtually anything you want into the cell. Uh we started the company about 3 years ago at this point. Uh we actually have over 100 partners now uh including a number of the big pharma and academic institutions and we have research scale systems uh high throughput versions that we more

recently launched and clinical scale systems. Now, to give you a sense for how we think about the delivery space overall, uh, and if you wanted a reference and help sleeping tonight, we had a review in nature back in 2016 that'll put you down. If you think of a matrix of cell types versus cargo, uh, delivery of nucleic acids into cell lines tends to be quite easy, hence that green zone over there. Uh, delivery of nucleic acids into patient derived cells uh, can be more difficult. uh where it's this yellow zone because there's things you can do, things you can't do. Cells can get mad at you because you electrocuted them.

And then there's this red zone where there's a lot of material that's virtually impossible to deliver uh like proteins and permeable small molecules, peptides, etc. Uh that are very difficult for existing systems. And in our case, because portal's mechanism is simply diffusion, uh we enable the delivery of virtually anything you want uh into the cytoplasm. And this works well across cell lines. and patient derived cells. Our one weak point uh is plasmids because we don't directly deliver the plasmids to the nucleus ourselves. Our mechanism goes to the cytoplasm and from there you need a chaperon or something else to help pull the DNA into the nucleus.

We've also shown over the years that with mechanical delivery you are able to maintain normal cell function. uh so for example if you're looking at the left with uh primary human te- cells we've shown that after mechanical delivery they'll proliferate normally uh whereas with methods like electropration you tend to get uh this disruption of normal cell function and so they can't proliferate normally or in that middle panel we've shown with hematopoetic stem cells a similar phenomenon where when you do mechanical delivery they'll engraft normally uh when back in an animal whereas with electroparation they won't uh and this all comes down to gene expression So if you're looking at the panel on the left, if you look at a full transcriptto microarray of gene expression of cells and compared to untreated things like electroporation tend to cause a lot of dysregulation, whereas with mechanical delivery, we

seem to keep the cells pretty normal. And in the context of drug screening assays, there's been a lot of interesting use cases to think about where uh we can on the one hand deliver many different probes into cells which enables you to engineer many different functions about the cell. uh and we have some of our partners from Promeon today too to help with any questions that might come up from our partnerships there. uh and the second side has been delivery of impermeable peptides and small molecules into cells uh such that you can assess their functions before going through something like a medcam optimization. Uh another recent area that has been pretty active for us is actually uh looking at novel ways to do perturbse seek for data generation for training AI models and other applications. Uh because if you think of the status quo on the left, people are often doing a single perturbation of a

cell and then measuring many different readouts about it. But for a complex system, if you only alter one parameter at a time, you may never be able to model or understand the interplay of these different parameters together because there's many different feedback loops and amplification u amplifications of signal that can occur inside a live cell. So with portal on the right because it's easy to deliver many different materials at once, we allow you to actually engineer multiple uh alter multiple parameters at the same time and now create much richer data sets for these models. Then one recent collaboration we had announced uh relates to our work with Harvard Reagan Institute and Microsoft around engineering different immune cell uh parameters to try to better understand the evolution of immune responses in the context of vaccinations and other u infectious disease applications.

And more broadly, just thinking about the platform overall, we think that this can be essentially one platform to rule them all where it seems to work across cell types as well as cargo classes providing a single method to go across many different applications. Uh secondly, in that middle panel, as you'll see later in the presentation, it's fairly easy to integrate this with existing high throughput robotics. Uh so going from low throughput research scale to higher throughput screening approaches has become pretty seamless with our latest generations of the system. Uh and finally from cost perspective we believe this has been pretty costefficient because in our case a typical high throughput sample is going to be 50 cents or less per well uh for the delivery step whereas alternatives like electrifation tend to cost uh $10 or so per well. And so we think this can be far more costefficient

uh for doing high throughput screens or doing high throughput data generation. There's four different scales at which we've implemented the technology. There's the research scale systems, high throughput systems and clinical scale systems both for attacking existing GI equipment as well as going to the point of care. Uh we won't cover the clinical scale systems today but if there's any questions on that uh please let us know.

For the basic research unit, it's a fairly simple instrument uh which is going to provide different pressures to run cells through our cartridges. And those cartridges that you see on the right are what contain the silicon membrane. So we have different cartridges with different pore sizes that enable you to do delivery uh across different cell types by varying parameters like the speed at which the cells go through and the size of the pores through which they're going. uh and one example of our past work in the drug screening space has been work that we published with Fizer showing that in the context of impermeable small molecules over here they had some impermeable jack stat inhibitors going into PBMC's uh you can elucidate what kind of a difference it makes uh to actually get the molecule into the cell versus letting it uh act on its own and in this case for example compound number five

has really high activity if you could get it into the And so when it comes to uh prioritizing molecules for medcam optimization, in this case compound number five seemed most interesting where by default it's impermeable, but if you could get it into a cell, it could be quite potent. Uh in this case in stat 5 phosphorilation inhibition. Uh we've also shown this application across many other material types. So we have other partners that work with cyclic peptides for example and you can get pretty robust uh delivery with those. In this case over 80% of the cells will contain the cyclic peptide.

We've also applied it to alternative like context of Dells the small molecules you're looking at might be permeable but the DNA tag definitely isn't. And so right now all Dell screens are done in lysates or uh biochemical based systems but by being able to deliver them into the cell you can now uh assess their binding in a live cell context which can be much more relevant for the ultimate screen and quality of what comes out of it versus doing this in a lysate or biochemical system.

And it's quite easy for us to deliver multiple things at once. Uh so data over here you're looking at delivery to unstimulated tea cells where we're delivering uh three different materials all at the same time. So VEXrand sugar polymer an mRNA and a crisper complex. Uh so three chemically very different things. And as you can see in the bar chart on the right we get about 85% triple positive cells. And you're looking at the fast clots, you can see that essentially all the cells that are expressing the GFP mRNA are also knocked out for the B2M, which is what our crisper complex was targeting, indicating that if one material goes in, the rest go in, which is what you would expect from diffusion. And therefore, multi-engineering of cells is quite simple. uh and through one of our other partnerships with MGH, we've been able to show uh delivery of multiple circular RNAs simultaneously for example where in

this case uh they were co-delyivering a RNA for a CD19 CAR as well as a membrane bound IL12 and showing that you get over 75% of these T- cells to be double positive expressing both the CAR and the IL12 uh highlighting how this kind of multi-engineering function can be quite useful in the context of cell therapies in addition to research scale uses. Now, for going to our high throughput setup, uh we've been trying to make this as seamless as possible and leveraging the existing infrastructure as opposed to necessitating uh a lot of new capital equipment for people to be able to implement this is to integrate with a lot of dispenser technologies. Uh so just as a conceptual example over here you can see one of those integrations where this is a typical dispenser that is going to go and dispense cells into a well and we added a cartridge in between such that now as the cells are going through uh

they have to go through one of these silicon membranes which will disrupt uh the cell and because the disruption lasts 30 seconds you can just have the cargo in the well. Um, so you can imagine having a plate with many different cargos in each well. And now the disrupted cells that are being dispensed onto those wells will pick up whatever material is inside them because they're still in that 30-second permeability window when they're dispensed. And we've shown you can get fairly consistent uh delivery of material to these cells. Uh so in this case uh you're looking at a single cartridge going across 10 plates. This is highlighting plate number two and plate number seven where you can see fairly consistent delivery across the board uh from the single cartridge enabling you to uh implement this for a high throughput screening context uh to look at many different compounds at once or many different types of conditions at

the same time. Uh we've been integrating with a lot of different types of dispenser robots. Uh and it's typically a subtle integration uh that's reversible. So the robot can be used for its normal functions and then when you want to do a delivery, you just pop in one of the portal cartridges and then take it off when you're done. Uh in particular uh we're excited about our partnership with uh High-Res where they have their precise drop 2 which we've been integrating with and we have uh a number of users implementing the PD2 for their high throughput uh screens and leveraging our system to add novel delivery and assay capabilities. Uh we've also been excited to integrate with Nano Certis Flex uh which has very similar functionalities as far as being able to do uh high throughput implementation of the novel assays that portal enables.

And to give you a for what some of these look like uh in a kind of live format, this is the Cirus Flex integration where you can see uh off of a single channel, it still runs pretty fast. you can do a plate in about 20 seconds using this. So, it's fairly efficient uh to run through the delivery. And then similarly for the PD2, you can go across a plate fairly quickly uh in a very similar architecture where the cells are getting uh boosted as they go through and they'll pick up whatever cargo is in the well below them.

uh and for some of our partners they've been implementing this in the context of crisper screens as well. So in this case you're looking at uh delivery of crisper complexes to unstimulated tea cells where there's uh crisper complexes in the various wells and we were showing you maintain fairly high viability of these tea cells uh a little over 70% viable tea cells and get pretty good uh knockout efficiency on the other side.

So 70 80% knockout efficiency across the plate. So if one is looking at different guides or different targets, you can also implement crisper screens at high throughput. Another nice feature with going high throughput by nature of our mechanism is that dose titration is also a predictable thing to do. Um so in this case you're looking at uh for the first few graphs delivery of cyclic peptides where if you look at the histograms over here uh on the left bar of the histogram there's different concentrations of cyclic peptides in the wells and so as you increase the concentration of cyclic peptide in the wells you get more and more material into the cells. Uh and then on the far right this was actually delivery of RNA into cells to give expression of a surface antigen of interest. Um so this is useful to people doing u bifunctional antibodies uh or other multisspecific biologics and you can see as you increase the amount of

RNA you get a fairly linear increase in the level of antigen expression on the surface of these cells too. Uh so if you want to look at different affinity biologics this could be a nice way to screen against that. Another big application area for us has been the delivery of various probes into cells. Um, so for us, because it doesn't really matter what the chemistry of what you're trying to deliver is, uh, if it's an impermeable molecule that's in solution, it's simply going to diffuse into the cell, it opens up a lot of new assay capabilities as well. Uh, and this is an area that we've been working a lot with uh, our partners at Promega in addition to some others. Uh, and one example of this is been delivery of large bit protein into cells. So if you imagine a cell that already has a high bit tag, we've shown that you can simply deliver the large bit protein. And now if you're looking at the luminescent

signal, uh you'll get a pretty strong signal for large bit showing the protein expression of interest. And then when you add on a degrader that's going to degrade that protein, you can watch that expression go away. Uh giving you a way to measure protein levels in a live cell without needing to lice them. Uh another related side to this has been delivery of impermeable tracers into cells. So a lot of times people might have a tracer that binds a drugable pocket of interest, but many very often those tracers can be impermeable. So in this case, we're showing that you could deliver those impermeable tracers, have them occupy the pocket. Um, so you get a pretty strong breit ratio and then when you add on the inhibitor molecule of interest that you're trying to assess, you can watch it displace away the tracer all in the live cell context so that you have maximum quality and relevance of data that you're

generating. Uh, and finally, as another example, uh, we've shown that you can deliver whole antibbody into cells. So you can measure untagged proteins even in a primary cell context. Uh this was a bit of a tour to force because we were co-elivering four different antibodies at once. Uh so two primary antibodies that were going to bind different parts of a phosphorolated BTK molecule. Uh and then two secondary antibodies that have the lumit system on them such that when they're in proximity they're going to complex and generate a or form a complete luciferase like enzyme to generate a luminescent signal.

uh and so you can see from the data in a lysate context this is the kind of signal to noise you would expect uh provenate is a drug that'll induce BTK phosphorilation so you get a sense for the contrast you would have been able to see in a conventional lysate based assay and in our case when you just deliver these proteins you can get a similar signal to noise ratio but now measuring these protein levels in a liel context so you can try to look at kinetics or potentially select uh based on these signals and isolate live cells of interest. Uh and so that's kind of an overview for the portal side of this before I hand it over to Milad where we think we have a platform that can broadly enable delivery of virtually any material into any cell type at scale where now there's many opportunities for novel drug discovery assays as well as cell engineering. Uh and with that mad I'll hand it over to you.

Okay, thank you so much Armon. So let me just share my slide. Okay. Uh can I see my slide in presentation mode? Yep, you're good. Okay, perfect. So yeah, thank you so much Armen and uh good afternoon everyone. My name is Mulad. I'm a senior scientist at AB in esma molecule therapeutics and platform technologies group. And today I want to talk about the importance of portal in uh drug discovery and platform enablement and how it can help actually uh overcome one of the key challenges we face in early discovery which is cell permeability. So here is my disclosure. So you know as we all know in many screening campaigns compounds fail uh not because they lack activity but simply because they cannot enter the cells and as a result truly valuable chemical matters can be mistakenly discarded as inactive. In other words uh permeability becomes a gatekeeper generating false negatives and hiding real biology. So now the key

question becomes how do we evaluate the true cellular potential for impermeable molecules and this is exactly where portal technology changes the game. Portal uh as Armon mentioned enable the delivery of impermeable cargo directly into the cells uh allowing us to evaluate compound potency and mechanism of action independent of permeability constraint. And today I will show you how this technology can open new opportunities uh for studying compounds and mechanisms that would otherwise remain inaccessible in cellular um assays. So let's look at some data now.

Uh and here I apologize that the target names and compounds names and uh structure are blinded as we are not allowed to disclose those details for our pipeline projects in public. But uh what you see here is a table from one of our pipeline project showing a series of a small molecule inhibitors that uh demonstrate a strong binding to the target in our biohysical selfie SPRSA. However, when we look at the cellular uh activity data, we start to see a different story. And as you can see here, all uh these compounds um show a great actually a significant loss of potency compared to permeable controls even though they only contain minor S modification. And actually this kind of disconnect uh between biohysical self-rebinding data and cellular activity data especially for a small molecule inhibitors uh as a drug modality is often a strong indicator that uh uh you know cell permeability may be limiting the cellular activity of

this uh compound. So because of that we decided to you know test this compound with and without portal in our cellular activity assay which was a cell viability assay. But before doing that it's important actually whatever cell line that you are using it's important to optimize and uh you know uh establish your uh basically optimal uh condition for your cell line. Um so for example here we tested different boosters and different pressure and we found that for example for this specific cell line calistic cells the boosters with 11 micron size and the pressure of 12 psi uh is actually the uh best condition for seeing some activity. So after you know optimizing the condition we uh decided to now look at the whole uh library with and without portal. So uh as you can see here for the permeable controls compound one and two you can see the exact same potency around 80% uh cell cleaning in both intact cells and boosted cells. But

when you look at the other four compounds at concentration of one nanom you can see all of them are completely inactive in intact cells. But when we deliver those into the cells using portal now you start to see a variable degree of activity from this compound especially for compound 4 that's showing around 85% of cell cleaning potency um you know up um delivering into the cell using portal and actually you know you can use this for any other assays and any drug modalities uh if there are per uh impermeable or partially permeable for example we also use it for um measuring the activity of protein degradators and as you know unlike traditional small molecules uh protein degradators actually induce proximity between target protein and liase. So it induced the ubiquitination and porttomal degradation of uh target protein. So one of the assay that people use for measuring the activity of protein

degraders called nonobit assay or sometimes people call it hybrid assay. So for example here we actually look at the uh degradation potency of uh compound one with three um you know different s uh so as you can see here we have esester compound and ethylester compound that are our permeable control and as you can see they show like similar potency in intact and permeable cells but when you look at the acid compound which is our partially permeable compound you can see in intact cells or no boosted cells they show around like 20% degradation. But when you deliver those into the cells using portal, you start to see higher uh potency with around 50% uh degradation uh activity. And uh you know uh our group actually focusing we are focusing on targeted protein degradation and when it uh you know in a word of targeted protein degradation actually understanding mechanism of action or MOA is not just an academic exercise. It's

essential because unlike uh traditional small molecules, protein degraders don't just block function. They induce dynamic multi-step processes depends on turnary complex formation, ubiquitination and porttom recruitment. And without knowing MOA, it's almost impossible to predict uh selectivity, optimize potency or troubleshoot why a compound fails. And that's exactly why a robust assay uh to characterize MOA is essential not only for building confidence in protein degraders as a drug modality but also for guiding their development and you know although we have biohysical biochemical and self-preass and they're actually crucial for uh you know uh characterizing the MO of compound and we know that they are robust and quantitative but you know they don't encompass physiological complexity of the full lens protein in the presence of cellular millu and regulatory circuits that modulate protein function. So this

is why it's important to be able to study the MOA of and characterize the MOA of compounds in live cells. So specifically we developed a nonobre MOA panel uh contain assay that measure turnary complex formation actually the protein protein interaction between target protein and it lies often like induced proximity and also another assay that measure ubiquitination of the target protein as well as an assay that measure recruitment of target protein to the protosmo machinery and these are all nonbread assay which is a proximity based assay. So um if you want to show if I want to show you some data here is like u uh we have like a permeable control and two partially permeable compound. So you can see you know with a permeable control there is no difference in uh turnary complex formation with and without portal. But when you look at the two partially permeable compound you can see in the presence of portal when we

deliver those using portal we start to observe greater potency in inducing turnary complex formation and we actually observe the same pattern for ubiquitination and portal recruitment where portal delivery increase the potency of these partially permeable molecule and some of actually one of them is even like much uh more potent than even the permeable compound. So you know this is very important when we can do this uh you know for partial permeable or impermeable molecules because it allows us to you know um uh kind of identify false negatives early and not lose you know valuable chemical matter. And uh finally I would like to briefly highlight the highlight actually how we use portal to enable a new uh crisper platform that we developed uh which we call it P2A flanked uh uh crisper platform and actually as Arman just mentioned and actually as uh also uh the portal team already showed the uh

this technology the portal technology is highly efficient for cur for CAS9 RMP delivery into the cells and for knockout studies. is however because the donor DNA and in general like the uh we know the impermeable molecules and cargos don't efficiently localize into the nucleus using this uh technology. It has been less optimal for knockin or um actually base editing application. So to address this we designed and developed a P2A flank donor design uh where we synthesized the donor DNA template as a single stranded DNA and we paired that with CTS or CAS9 targeting sequence which is complimentary to the three uh five prime or three prime end of the donor. So uh this don actually CTS sequence allows the donor template to actually associate with the CAS 9 and RMP. So it co- transansport to the nucleus up and delivery by portal because the CAS 9 has a NLS. So it can help like coransport the whole complex

uh to the nucleus and actually using this uh uh strategy we were able to efficiently uh enable precise uh knock in as well as uh base editing in our cell models. And here you can see one of the examples where we knock in a luminescence tag on the uh target gene. And you can see the luminescent signal for pool cells and clone colonal cells uh after selection. And uh so to summarize my talk I would like to say the key advantages of this uh technology is for us you know as a drug discovery group is that it enable direct assessment of compounds potency and mechanism of action independent of permeability. So as a result it will allow us to identify false negatives early. It will decouple potency from permeability and more importantly it will reduce later stage attrition risk because it will allow us uh to actually uh let permeability to be addressed as an engineering problem rather than a biological unknown and the lesson that

we learned from using this technology is that portal uh is not actually optimal for permeable compound and the reason I'm saying that is not uh uh is because I mean if you look at the detail protocol there are some especially for low trap uh system there are some um actually dilution after you boost the cells. So if you're using a permeable control you will dilute it out. So if you want to use the permeable control and premix it with the cells you should actually consider the dilution. So you use like higher concentration because you will dilute out your compound or uh pre-pot the drug into the well and then boost the cells and add the cells to the wall instead of premixing. But for imperial molecule it's fine because as soon as they enter the cells and the membrane just uh you know repair they are just you know trapped into the cell.

So there's no dilution associated with that. And also for uh if you're using then a cellular assay that is depends on you know luminescence or florence signal it's crucial to normalize it with cell viability because every time you boost the cells using the uh uh the low output version of this technology uh you know the viability or the number of cells might be different a little bit. So uh to have a very accurate data is uh suggested to always have the normalization in each well uh with no know the viability of the same well just to make sure the signal is you know is not because of you know the difference in viability and as I mentioned the assay outcome are also highly sensitive to the booster size and you know the pressure actually the condition that you optimize so it's crucial to optimize your condition first for a specific cell lines and uh then move forward with screening your library and at the end I

would like to acknowledge our leadership uh whose support actually made it possible for us uh to establish and advance this technology at Abby and at the end thank you so much for your time and I would be happy to answer any question. Uh thank you. All right, thank you. Um, if folks have any questions, feel free to throw it into the chat. Um, all right. One of the questions is, "How would you deliver multiple cargos at once?" Uh, so it's fairly simple. We just mix it into the same solution and run the cells together with it. Uh, if it's in the low throughput versions, you can premix that with the cells. In the high throughput versions, I would just put all the different cargos into the well and you can go from there.

Any other questions? Oh. Um, do most cancer cell lines use the same pore size? Uh, they tend to be in the same range. They're not explicitly the same uh pore size, but the same three, four pore sizes uh tend to be the most common. So, it's fairly easy to narrow it down uh when establishing an essay. And these are the kinds of things that we're more help with along the way. Um let's see. Uh it was intriguing to see large bit delivery into the high bit cell lines. Have you been able to implement this into the tricky b cell lines like ramos or tmd8? Uh ma did you do ramos or tmd8?

Uh I think I did uh yeah I did I think I did ramos cells not for lar but for you know for other like for crisper things. Yes. Yeah. Okay. Yeah. And I think um I think our team has done Ramos as well. I mean, we've done a lot of primary B cell work. I didn't cover it in our slide deck because it was more relevant to cell therapy applications, but we'd expect B cells to generally work just fine. Uh what is the largest cell you can deliver cargo to? Uh I don't think our current chip designs would work for oasittes. uh but most cancer cell lines and everything have been fine and most primary cells have been fine. Uh meggaaria might be a problem. Uh but DC's macrofasages fiberblasts uh all these other cell types have been fine unless there's a specific one you guys are wondering about.

Um, can you use 384 wall plates and how's the uniformity of dispensing cells across the plate? Uh, yes, you can use 384 wall plates uh for the high throughput system. Uh, we actually had a webinar with Merc almost a month ago where they've been implementing it for 384 well plates. I'll admit at portal we don't do too many 384 wall plates ourselves. uh the kinds of things we do internally are more 96 well but others have successfully imp implemented it for 384.

Um and then how tolerant is the technology for permeabilizing cells of different sizes in a suspension that differ by a few microns. Uh one interesting use case that we have done and we have data for that we're happy to share is delivery to PBMC's. uh cuz with PBMCs it's a mix of T- cells, B cells, ENKs and monos and you can select poor sizes and delivery conditions that will deliver to all four of those subtypes together with around 70% plus delivery efficiency to each. Uh admittedly, when you have a mixed population, it's a little hard to get to let's delivery efficiency for all of them because of their subtle differences. Uh but if cell types are fairly similar in properties, you can run them um as a mix.

Uh are there low permeability fluorescent compounds perhaps in another channel that can be can act as permeability enhancement controls? Uh yes. So actually one thing we very commonly do is delivery of uh floror tagged dex strands. Uh and because co- delivery of compounds is fairly easy in our system uh we actually highly recommend co- delivery of an impermeable control essentially uh so that you always know what your delivery efficiency is and you can even normalize against it uh because if one cargo goes in the rest go in. So if your detectable impermeable control is let's say 70% delivery you know that whatever your active compound was should be in those same cells.

Um, could you run a full nanorit target engagement screen at 34 well format on Galaxy I what would that end to end workflow look like? Uh, you should be able to. Uh, I admit I'd have to ask one of our, uh, scientists on the ground that's more in the details of the workflow. Uh, but I do believe we have some of these protocols on our website. But if you send us a note later, uh, happy to share more info on that. Is the cell membrane permeability induced primary due to disruption while passing through the cartridge or isn't an additive necessary? Uh no, no additives necessary. You run this in standard buffers like Optimum or whatever your preferred buffer is. We don't have any additives.

What was the delivery efficiency? Uh it depends on the assay and the cell type and your conditions but uh for most cell types you could easily get to over 70% delivery with a little bit of optimization. Have you tested this in protozoans or mostly mamalian cells? Uh internally we only do mamalian cells. We have had partners uh thinking about other cell types. uh we're not sure what would happen there. So if you're interested, happy to connect with the team and explore that, but we're not sure what would happen. Uh cell walls might be a problem. Uh if it's something without a cell wall, I would guess it would work.

Can insoluble cargos be delivered into cells with this technology such as mag beads coated with antibodies? Would these clogged the pores? uh we actually have delivered iron nanop particles to cells. Uh so as long as you can get suspension, yes, you should be able to deliver it. If it's above 100 nanometers in size, that would start to be a problem in our experience. Uh but yes, we have delivered magnetic beads and actually one of our academic partners uses us for delivering iron nanoparticles and then doing um tracking of cells in vivo with MRI. Uh so there's interesting things you can do by putting particles in.

Uh and for Rob's question, will the presentation be available online? Yes, it will be. Uh and then from Andrew, how much leakage of cytoolic contents occurs during the 30 seconds of permeability? Have you seen transfer between different cells if mixed in the well? Eg. Could complimentation be assessed? Um, it's been hard to assess how much material leaves the cytoplasm. Our best understanding is that things like ions, which are tiny and diffuse super fast, probably equilibrate almost instantly with the surrounding environment. And so the cell needs to reestablish membrane potential after it reseals.

um other materials that we've tracked by flowcytometry like let's say if a cell line is GFP positive how much GFP leaves or other detectable proteins it doesn't seem like much leaves like it's not really detectable by flow in principle we do think some of it leaves um I think it's highly improbable material will get transferred from one cell to another cuz the thing I would keep in mind is in a solution that's for example 10 million cells per mill. The actual volume of your cells is probably 1% of the entire solution volume. So on average any cell is going to be very far from another cell. Uh and therefore it's not like I I don't think it's likely cytoolic material will get transferred between cells uh in these systems.

Have you ever attempted delivery into mitochondria using the system? Uh, we have not attempted it. If you have a protein, for example, that has a I don't know what it's called, but whatever the equivalent of a mitochondrialation sequence is, it should go there. Um, I would just think of it as we put material in the cytoplasm. From there, if you have a tag that's meant to engage a transporter that'll take it somewhere else, that should happen because NLS's work just fine. Um, so I would guess that that would work fine.

Any other questions? Uh if doing a Dell screen, what scale of portal instrument would be needed? Also, are the DNA tags used in Dell screening optimized to be insusceptible to cellular nucleases? Uh I think it depends on your approach to the Dell screen. Uh I admit I don't know much about how people do the readouts, but from our users that do use it, they tend to just use the lower throughput system. uh or if they're trying to do subsegments of their library, then they would use a high throughput system for doing a plate or two like a 96 well.

Um I don't know enough about how resistant to the nucleases the Dell the DNA is, but your binding event should occur within minutes or under an hour. And in our experience, the DNA is not going to be significantly degraded during that kind of time frame. If you're doing a 24 or 48 hour readout, uh maybe more of it would be degraded. Uh we're not sure because we don't do those screens and our partners use it for dell screens.

This one's for you. uh did your colleagues unfamiliarity with the technology ever lead to push back to making project decisions based on assays using portal? So yeah I mean as I said I mean you know for S studies is very important because for example when we find you know there's an impremable chemical matter that show like higher potency compared to like a permeable control that we are using. So you know we can say that chemical matter is much more active compared to what we have right now. So you know as I said the permeability will be engineering problem. So you know our medicinal chemistry team can work around that chemical matter and make it more permeable and keep that you know activity uh on the compound. So yeah I mean that happened for us. Um but yeah all right. Um, any other questions?

Well, if no other questions, thanks to everyone for uh joining. If there's anything that you think of afterwards, definitely feel free to reach out to us. Happy to. And if there's any more specific technical questions too, we can always link you up with one of our science team uh to chat through it. Thanks again and thanks for joining from the side. Uh appreciate it. Thank you so much. Thank you so much. Bye. See you everyone.

The transcript is the webinar's YouTube auto-generated caption track. It is included in full in the page HTML. Auto-generated captions can mishear names and technical terms.